Javascript must be enabled to continue!
Spatially resolved electrical impedance methods for cell and particle characterization
View through CrossRef
AbstractElectrical impedance is an established technique used for cell and particle characterization. The temporal and spectral resolution of electrical impedance have been used to resolve basic cell characteristics like size and type, as well as to determine cell viability and activity. Such electrical impedance measurements are typically performed across the entire sample volume and can only provide an overall indication concerning the properties and state of that sample. For the study of heterogeneous structures such as cell layers, biological tissue, or polydisperse particle mixtures, an overall measured impedance value can only provide limited information and can lead to data misinterpretation. For the investigation of localized sample properties in complex heterogeneous structures/mixtures, the addition of spatial resolution to impedance measurements is necessary. Several spatially resolved impedance measurement techniques have been developed and applied to cell and particle research, including electrical impedance tomography, scanning electrochemical microscopy, and microelectrode arrays. This review provides an overview of spatially resolved impedance measurement methods and assesses their applicability for cell and particle characterization.
Title: Spatially resolved electrical impedance methods for cell and particle characterization
Description:
AbstractElectrical impedance is an established technique used for cell and particle characterization.
The temporal and spectral resolution of electrical impedance have been used to resolve basic cell characteristics like size and type, as well as to determine cell viability and activity.
Such electrical impedance measurements are typically performed across the entire sample volume and can only provide an overall indication concerning the properties and state of that sample.
For the study of heterogeneous structures such as cell layers, biological tissue, or polydisperse particle mixtures, an overall measured impedance value can only provide limited information and can lead to data misinterpretation.
For the investigation of localized sample properties in complex heterogeneous structures/mixtures, the addition of spatial resolution to impedance measurements is necessary.
Several spatially resolved impedance measurement techniques have been developed and applied to cell and particle research, including electrical impedance tomography, scanning electrochemical microscopy, and microelectrode arrays.
This review provides an overview of spatially resolved impedance measurement methods and assesses their applicability for cell and particle characterization.
Related Results
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
Human tissues comprise trillions of cells that populate a complex space of molecular phenotypes and functions and that vary in abundance by 4–9 orders of magnitude. Relying solely ...
Impedance -based Stability Analysis on IBR Integrated Power System
Impedance -based Stability Analysis on IBR Integrated Power System
<p dir="ltr">This thesis examines the small-signal stability of inverter-based resources (IBRs) in a power system that contains grid-forming inverters (GFMs) using impedance-...
Experimental and numerical investigation into the effect of surface roughness on particle rebound
Experimental and numerical investigation into the effect of surface roughness on particle rebound
Erosion damage and particle deposition are crucial wear phenomena in gas turbine engines. As a result, compressor efficiency decreases, stability margin reduces, and maintenance co...
Solder joint degradation and detection using RF impedance analysis
Solder joint degradation and detection using RF impedance analysis
PurposeThe purpose of this paper is to clarify the method of using RF impedance changes as an early indicator of degradation of solder joint. It proposes the mode of crack propagat...
A simplified Python-based kinematic model of particle transport in rivers
A simplified Python-based kinematic model of particle transport in rivers
We present results from a particle-scale numerical model inspired by the idea that a majority of the time during transport capable floods, bedload transport in rivers is rarefied, ...
Unusual Presentation of Alice in Wonderland Syndrome: A Case Report and Literature Review
Unusual Presentation of Alice in Wonderland Syndrome: A Case Report and Literature Review
Abstract
Introduction
Alice in Wonderland Syndrome (AIWS) is an uncommon and frequently overlooked neuropsychiatric condition, marked by brief episodes of altered visual and somato...
Imputation of Spatially-resolved Transcriptomes by Graph-regularized Tensor Completion
Imputation of Spatially-resolved Transcriptomes by Graph-regularized Tensor Completion
AbstractHigh-throughput spatial-transcriptomics RNA sequencing (sptRNA-seq) based on in-situ capturing technologies has recently been developed to spatially resolve transcriptome-w...

