Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Reference Measurement Procedure for Total Glycerides by Isotope Dilution GC-MS

View through CrossRef
AbstractBACKGROUNDThe CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum.METHODSWe diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [13C3]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b).RESULTSThe calibration response was linear for the range of calibrator concentrations examined (0–1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123–0.7225) and 0.3122 (95% CI, 0.3096–0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%.CONCLUSIONSThis ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.
Title: Reference Measurement Procedure for Total Glycerides by Isotope Dilution GC-MS
Description:
AbstractBACKGROUNDThe CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing.
The CA RMP has several disadvantages, including lack of ruggedness.
It uses obsolete instrumentation and hazardous reagents.
To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum.
METHODSWe diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [13C3]-glycerol.
These samples were incubated and hydrolyzed under basic conditions.
The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS.
Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b).
RESULTSThe calibration response was linear for the range of calibrator concentrations examined (0–1.
24 mmol/L) with a slope and intercept of 0.
717 (95% CI, 0.
7123–0.
7225) and 0.
3122 (95% CI, 0.
3096–0.
3140), respectively.
The limit of detection was 14.
8 μmol/L.
The mean %CV for the sample set (serum pools and SRM) was 1.
2%.
The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.
7%.
CONCLUSIONSThis ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.

Related Results

Resolving the Hf-Nd paradox of early Earth crust-mantle evolution
Resolving the Hf-Nd paradox of early Earth crust-mantle evolution
<p>One of the fundamental tenets of geochemistry is that the Earth’s crust has been extracted from the mantle creating a crustal reservoir enriched&...
The value of water isotope data on improving process understanding in a glacierized catchment on the Tibetan Plateau
The value of water isotope data on improving process understanding in a glacierized catchment on the Tibetan Plateau
Abstract. This study integrated a water isotope module into the hydrological model THREW which has been successfully used in high and cold regions. Signatures of oxygen stable isot...
Improving calibrations of in-house water isotope standards using CRDS and OA-CRDS: memory effects versus drift
Improving calibrations of in-house water isotope standards using CRDS and OA-CRDS: memory effects versus drift
<p>The isotope composition of rainfall provides information on the initial isotope composition of the moisture source, conditions during evaporation and condensation ...
Release characteristics of drug having different solubilities from matrix pellets containing glycerides
Release characteristics of drug having different solubilities from matrix pellets containing glycerides
The release properties of having different solubilities (propranolol hydrochloride and diclofenac sodium) from the glycerides matrix pellets were investigated. The pellets were pre...
Isotope Dilution Mass Spectrometry
Isotope Dilution Mass Spectrometry
Isotope Dilution Mass Spectrometry (IDMS) has become an essential tool in research laboratories and is increasingly used in routine analysis labs (including environmental, food saf...
A Reliability Analysis of the Dilution Graph Method for Open Stope Design: A Case Study
A Reliability Analysis of the Dilution Graph Method for Open Stope Design: A Case Study
ABSTRACT The equivalent linear overbreak slough (ELOS) graph is a commonly used empirical design method for open stope design. Nevertheless, this method can lead ...
Modelling the early Cenozoic Antarctic ice sheet oxygen isotope ratio and implications for the benthic δ18O change
Modelling the early Cenozoic Antarctic ice sheet oxygen isotope ratio and implications for the benthic δ18O change
At the Eocene-Oligocene Transition (~34 Ma), ephemeral ice sheets grew into a large continental-scale Antarctic ice sheet. During the late Eocene there is evidence for short-lived,...

Back to Top