Javascript must be enabled to continue!
Miniaturized Planar Tomography for Multiphase Stagnant Sample Detection
View through CrossRef
Miniaturized device offers portability, high throughput and faster time response compared to macroscale devices. In microdevices, most of the application utilizes planar electrode for microanalysis process as it is inexpensive, highly controllable system and easy for installation. In addition, miniaturized planar sensor offers great potential for microscale medical diagnosis, chemical analysis, environmental analysis, cell culture application and single cell measurement using tomography measurement. In this project, a miniaturized planar tomography system is developed for multiphase sample detection such as liquid-solid and liquid-liquid. Eight-electrode device was fabricated on the copper plated printed circuit board (PCB) using the commercial fabrication technique. The ability of the proposed device in reconstructing images of a multiphase sample using Linear Back Projection algorithm is tested. Experimental results show that the reconstructed images closely resemble with the cross-section of the stagnant multiphase sample.
Title: Miniaturized Planar Tomography for Multiphase Stagnant Sample Detection
Description:
Miniaturized device offers portability, high throughput and faster time response compared to macroscale devices.
In microdevices, most of the application utilizes planar electrode for microanalysis process as it is inexpensive, highly controllable system and easy for installation.
In addition, miniaturized planar sensor offers great potential for microscale medical diagnosis, chemical analysis, environmental analysis, cell culture application and single cell measurement using tomography measurement.
In this project, a miniaturized planar tomography system is developed for multiphase sample detection such as liquid-solid and liquid-liquid.
Eight-electrode device was fabricated on the copper plated printed circuit board (PCB) using the commercial fabrication technique.
The ability of the proposed device in reconstructing images of a multiphase sample using Linear Back Projection algorithm is tested.
Experimental results show that the reconstructed images closely resemble with the cross-section of the stagnant multiphase sample.
Related Results
Implementation of multiphase metering on unmanned wellhead platform
Implementation of multiphase metering on unmanned wellhead platform
Abstract
In 1997 TotalFinaElf installed a multiphase meter on an offshore unmanned wellhead platform in the Middle East. The decision to go for the multiphase met...
New Pseudo-Pressure and Pseudo-Time Functions for Multiphase Flow
New Pseudo-Pressure and Pseudo-Time Functions for Multiphase Flow
Abstract
The development of pressure transient analysis was based on the assumption of a single phase slightly compressible fluid. This assumption was later relaxed ...
MMS 1200: Cooperation on a Subsea Multiphase Flow Meter Application
MMS 1200: Cooperation on a Subsea Multiphase Flow Meter Application
Abstract
PETROBRAS (Brazil) and FLIJENTA (Norway and USA) are since beginning of 1996 working on this multiphase flow metering route development under a Technolog...
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Multiphase Flow Metering:An Evaluation of Discharge Coefficients
Abstract
The orifice discharge coefficient (CD) is the constant required to correct theoretical flow rate to actual flow rate. It is known that single phase orifi...
Miniaturized Planar Sensor Development
Miniaturized Planar Sensor Development
This paper describes the process of developing a miniature device with planar sensors utilizing electrical capacitance measurement. The project investigates the feasibility and cha...
Virtual Flow Metering as an Emerging Flow Measurement Technology
Virtual Flow Metering as an Emerging Flow Measurement Technology
Abstract
The accurate measurement of multiphase rates of produced oil, water and gas has always been a significant challenge to the oil and gas industry. Over the la...
Advanced HEMT Characteristics of Epitaxial Quality-improved GaN by Using Patterned Sapphire Substract
Advanced HEMT Characteristics of Epitaxial Quality-improved GaN by Using Patterned Sapphire Substract
INTRODUCTION
Accomplishing with the booming market of personal communication services and the fifth generation (5G) mobile systems, the demands for high frequency an...
Indeterminate solitary vertebral lesions on planar scintigraphy
Indeterminate solitary vertebral lesions on planar scintigraphy
Summary
Objective: This study aims to evaluate the added value of hybrid SPECT-CT in differential diagnosis of indeterminate solitary vertebral lesion (SVL) on planar sci...

