Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Automation System for the Flexible Sample Preparation for Quantification of Δ9-THC-D3, THC-OH and THC-COOH from Serum, Saliva and Urine

View through CrossRef
In the life sciences, automation solutions are primarily established in the field of drug discovery. However, there is also an increasing need for automated solutions in the field of medical diagnostics, e.g., for the determination of vitamins, medication or drug abuse. While the actual metrological determination is highly automated today, the necessary sample preparation processes are still mainly carried out manually. In the laboratory, flexible solutions are required that can be used to determine different target substances in different matrices. A suitable system based on an automated liquid handler was implemented. It has been tested and validated for the determination of three cannabinoid metabolites in blood, urine and saliva. To extract Δ9-tetrahydrocannabinol-D3 (Δ9-THC-D3), 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) from serum, urine and saliva both rapidly and cost-effectively, three sample preparation methods automated with a liquid handling robot are presented in this article, the basic framework of which is an identical SPE method so that they can be quickly exchanged against each other when the matrix is changed. If necessary, the three matrices could also be prepared in parallel. For the sensitive detection of analytes, protein precipitation is used when preparing serum before SPE and basic hydrolysis is used for urine to cleave the glucuronide conjugate. Recoveries of developed methods are >77%. Coefficients of variation are <4%. LODs are below 1 ng/mL and a comparison with the manual process shows a significant cost reduction.
Title: Automation System for the Flexible Sample Preparation for Quantification of Δ9-THC-D3, THC-OH and THC-COOH from Serum, Saliva and Urine
Description:
In the life sciences, automation solutions are primarily established in the field of drug discovery.
However, there is also an increasing need for automated solutions in the field of medical diagnostics, e.
g.
, for the determination of vitamins, medication or drug abuse.
While the actual metrological determination is highly automated today, the necessary sample preparation processes are still mainly carried out manually.
In the laboratory, flexible solutions are required that can be used to determine different target substances in different matrices.
A suitable system based on an automated liquid handler was implemented.
It has been tested and validated for the determination of three cannabinoid metabolites in blood, urine and saliva.
To extract Δ9-tetrahydrocannabinol-D3 (Δ9-THC-D3), 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) from serum, urine and saliva both rapidly and cost-effectively, three sample preparation methods automated with a liquid handling robot are presented in this article, the basic framework of which is an identical SPE method so that they can be quickly exchanged against each other when the matrix is changed.
If necessary, the three matrices could also be prepared in parallel.
For the sensitive detection of analytes, protein precipitation is used when preparing serum before SPE and basic hydrolysis is used for urine to cleave the glucuronide conjugate.
Recoveries of developed methods are >77%.
Coefficients of variation are <4%.
LODs are below 1 ng/mL and a comparison with the manual process shows a significant cost reduction.

Related Results

Delta-8-THC: Delta-9-THC’s nicer younger sibling?
Delta-8-THC: Delta-9-THC’s nicer younger sibling?
Abstract Background Products containing delta-8-THC became widely available in most of the USA following the 2018 Farm Bill and by late 2020 were co...
Biochemical study of antioxidants level in saliva and serum of obese individuals who have a family history of type II diabetes mellitus
Biochemical study of antioxidants level in saliva and serum of obese individuals who have a family history of type II diabetes mellitus
The study includes a comparative study  biochemical  comparative study  between the blood and saliva at some pointers early diagnosis for diabetes type II in obese people and over ...
Method to Diagnose Diabetes through Saliva
Method to Diagnose Diabetes through Saliva
A. Background A prevalent long-term condition that has been linked to salivary amylase levels is diabetes mellitus (DM). Recently, salivary amylase diagnostics have been linked to ...
PO-258 Women's Freestyle Wrestling Athletes Prepare for Urine Ten Evaluation Before the National Games
PO-258 Women's Freestyle Wrestling Athletes Prepare for Urine Ten Evaluation Before the National Games
Objective Urine routines inspection was used as a kind of non invasive test method, which was used widely in the biochemical monitoring of athletes.The urine routine was monitored ...
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
A STUDY ON THE IMPACT OF MARKETING AUTOMATION ADOPTION
A STUDY ON THE IMPACT OF MARKETING AUTOMATION ADOPTION
Marketing automation adoption refers to the process of implementing and using marketing automation technology to streamline, automate, and measure marketing tasks and workflows. It...

Back to Top