Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development of knee exoskeleton for capturing energy from human knee motion

View through CrossRef
AbstractIn this paper, the design and experimental validation of a knee exoskeleton are presented. The exoskeleton can capture the negative work from the wearer’s knee motion while decreasing the muscle activities of the wearer. First, the human knee biomechanics during the normal walking is described. Then, the design of the exoskeleton is presented. The exoskeleton mainly includes a left one-way transmission mechanism, a right one-way transmission mechanism, and a front transmission mechanism. The left and right one-way transmission mechanisms are designed to capture the negative work from the wearer’s knee motion in the stance and swing phases, respectively. The front transmission mechanism is designed to transform the bidirectional rotation of the wearer’s knee joint into the generator unidirectional rotation. Additionally, the modeling and analysis of the energy harvesting of the exoskeleton is described. Finally, walking experiments are performed to validate the effectiveness of the proposed knee exoskeleton. The testing results verify that the developed knee exoskeleton can output a maximum power of 5.68 ± 0.23 W and an average power of 1.45 ± 0.13 W at a speed of 4.5 km/h in a gait cycle. The average rectus femoris and semitendinosus activities of the wearers in a gait cycle are decreased by 3.68% and 3.40%, respectively.
Title: Development of knee exoskeleton for capturing energy from human knee motion
Description:
AbstractIn this paper, the design and experimental validation of a knee exoskeleton are presented.
The exoskeleton can capture the negative work from the wearer’s knee motion while decreasing the muscle activities of the wearer.
First, the human knee biomechanics during the normal walking is described.
Then, the design of the exoskeleton is presented.
The exoskeleton mainly includes a left one-way transmission mechanism, a right one-way transmission mechanism, and a front transmission mechanism.
The left and right one-way transmission mechanisms are designed to capture the negative work from the wearer’s knee motion in the stance and swing phases, respectively.
The front transmission mechanism is designed to transform the bidirectional rotation of the wearer’s knee joint into the generator unidirectional rotation.
Additionally, the modeling and analysis of the energy harvesting of the exoskeleton is described.
Finally, walking experiments are performed to validate the effectiveness of the proposed knee exoskeleton.
The testing results verify that the developed knee exoskeleton can output a maximum power of 5.
68 ± 0.
23 W and an average power of 1.
45 ± 0.
13 W at a speed of 4.
5 km/h in a gait cycle.
The average rectus femoris and semitendinosus activities of the wearers in a gait cycle are decreased by 3.
68% and 3.
40%, respectively.

Related Results

Sagittal and Frontal Plane Knee Angular Jerk Effects During Prolonged Load Carriage
Sagittal and Frontal Plane Knee Angular Jerk Effects During Prolonged Load Carriage
Introduction: Musculoskeletal injuries are a costly military problem that routinely occur during training. Quantifying smoothness of knee motion, or angular knee jerk, m...
Active exoskeleton reduces erector spinae muscle activity during lifting
Active exoskeleton reduces erector spinae muscle activity during lifting
Musculoskeletal disorders (MSD) are a widespread problem, often regarding the lumbar region. Exoskeletons designed to support the lower back could be used in physically demanding p...
Design of Bio-Exoskeleton for Elbow Rehabilitation
Design of Bio-Exoskeleton for Elbow Rehabilitation
Abstract In this study, a methodology for designing a task-based exoskeleton which can recreate the end-effector trajectory of a given limb during a rehablitation ta...
Effectiveness of Soft versus Rigid Back-Support Exoskeletons during a Lifting Task
Effectiveness of Soft versus Rigid Back-Support Exoskeletons during a Lifting Task
This study investigated the influence of passive back-support exoskeletons (EXOBK) design, trunk sagittal inclination (TSI), and gender on the effectiveness of an exoskeleton to li...
Quantitative parameters of the kinetics and kinematics of the iatrogenic crouch gait pattern
Quantitative parameters of the kinetics and kinematics of the iatrogenic crouch gait pattern
The pattern of pathological crouch gait in patients with spastic paralysis is characteristic of diplegic forms and in natural development manifests itself usually after the age of ...
Investigating Knee Joint Position Sense After Anterior Cruciate Ligament Reconstruction in Male Soccer Players
Investigating Knee Joint Position Sense After Anterior Cruciate Ligament Reconstruction in Male Soccer Players
Purpose: Anterior Cruciate Ligament (ACL) injury is the most common knee ligament injury during exercise, with a frequency of 36.9 per 100000 individuals. The characteristics of th...

Back to Top