Javascript must be enabled to continue!
Predicting ablation difficulty for idiopathic ventricular premature contractions: the role of distance between earliest activation sites identified by near-field and first-deflection
View through CrossRef
Abstract
Background
Catheter ablation is an effective treatment for ventricular premature contractions (VPCs), but complete elimination can be challenging, particularly when the origin is deep within the endocardium. Near-field (NF) annotation primarily captures endocardial signals, focusing on local VPC activation, whereas first-deflection (FD) annotation captures a broader range of signals, including those from deeper myocardial sites. We hypothesized that VPCs originating from deep sites may show discrepancies in the earliest activation site (EAS) between NF and FD annotations.
Purpose
To investigate the relationship between the difficulty of VPC elimination and the spatial distance between the endocardial EASs identified using NF and FD annotations (NF-FD distance).
Methods
We retrospectively analyzed data from 26 patients (20 males; mean age: 58±11 years) who underwent catheter ablation for idiopathic VPCs. Ablation was targeted at the FD-identified EAS using power settings of 35–50 W for up to 3 minutes per site. Complete success was defined as the absence of VPCs post-ablation, while partial success was defined as a reduction in VPCs. Failure was defined as unchanged or increased VPCs after ablation. NF-FD distance was measured retrospectively (Figure 1).
Results
Ablation was completely successful in 21 cases and partially successful in 5 cases. The successful ablation sites included the left ventricular outflow tract (LVOT; n=13), right ventricular outflow tract (RVOT; n=9), and other sites (n=4). The mean NF-FD distance was 8.3±8.0 mm. The mean number of ablation points, total ablation duration, and total energy delivered were 11.8±8.0 points, 739±509 seconds, and 25,615±18,618 J, respectively. The NF-FD distance moderately correlated with the number of ablation points (R=0.664, p<0.001), strongly correlated with total ablation duration (R=0.789, p<0.001), and strongly correlated with total energy delivered (R=0.816, p<0.001) (Figure 2).
Conclusion
Discrepancies between the endocardial EASs identified by NF and FD annotations may reflect greater procedural complexity and difficulty in achieving VPC elimination.
Oxford University Press (OUP)
Title: Predicting ablation difficulty for idiopathic ventricular premature contractions: the role of distance between earliest activation sites identified by near-field and first-deflection
Description:
Abstract
Background
Catheter ablation is an effective treatment for ventricular premature contractions (VPCs), but complete elimination can be challenging, particularly when the origin is deep within the endocardium.
Near-field (NF) annotation primarily captures endocardial signals, focusing on local VPC activation, whereas first-deflection (FD) annotation captures a broader range of signals, including those from deeper myocardial sites.
We hypothesized that VPCs originating from deep sites may show discrepancies in the earliest activation site (EAS) between NF and FD annotations.
Purpose
To investigate the relationship between the difficulty of VPC elimination and the spatial distance between the endocardial EASs identified using NF and FD annotations (NF-FD distance).
Methods
We retrospectively analyzed data from 26 patients (20 males; mean age: 58±11 years) who underwent catheter ablation for idiopathic VPCs.
Ablation was targeted at the FD-identified EAS using power settings of 35–50 W for up to 3 minutes per site.
Complete success was defined as the absence of VPCs post-ablation, while partial success was defined as a reduction in VPCs.
Failure was defined as unchanged or increased VPCs after ablation.
NF-FD distance was measured retrospectively (Figure 1).
Results
Ablation was completely successful in 21 cases and partially successful in 5 cases.
The successful ablation sites included the left ventricular outflow tract (LVOT; n=13), right ventricular outflow tract (RVOT; n=9), and other sites (n=4).
The mean NF-FD distance was 8.
3±8.
0 mm.
The mean number of ablation points, total ablation duration, and total energy delivered were 11.
8±8.
0 points, 739±509 seconds, and 25,615±18,618 J, respectively.
The NF-FD distance moderately correlated with the number of ablation points (R=0.
664, p<0.
001), strongly correlated with total ablation duration (R=0.
789, p<0.
001), and strongly correlated with total energy delivered (R=0.
816, p<0.
001) (Figure 2).
Conclusion
Discrepancies between the endocardial EASs identified by NF and FD annotations may reflect greater procedural complexity and difficulty in achieving VPC elimination.
.
Related Results
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract
Introduction
Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
Cometary Physics Laboratory: spectrophotometric experiments
Cometary Physics Laboratory: spectrophotometric experiments
<p><strong><span dir="ltr" role="presentation">1. Introduction</span></strong&...
Keyhole-Based Site Selection for Kinetic Impact Deflection of Near-Earth Asteroids
Keyhole-Based Site Selection for Kinetic Impact Deflection of Near-Earth Asteroids
Given present-day asteroid discovery capabilities, near-Earth asteroids (NEAs) are routinely discovered. 3,123 NEAs were discovered in 2024 alone1. Furthermore, new telescopes such...
Premature ventricular contractions originating from the left ventricular septum: Results of Radiofrequency Catheter Ablation in twenty patients
Premature ventricular contractions originating from the left ventricular septum: Results of Radiofrequency Catheter Ablation in twenty patients
Abstract
Background
RFCA has been established as an effective and curative therapy for severely symptomatic PVC from the outflow tract in structu...
Premature Ventricle Contraction Ablation in Cardiac Sarcoidosis
Premature Ventricle Contraction Ablation in Cardiac Sarcoidosis
Abstract
Background
Premature ventricular contractions (PVCs) are common and often benign, but in patients with structural heart disease—including cardiac sarcoidosis (CS)—...
Voiding symptom severity varies independently from non-adrenergic prostate smooth muscle contractions in patients undergoing surgery for benign prostatic hyperplasia
Voiding symptom severity varies independently from non-adrenergic prostate smooth muscle contractions in patients undergoing surgery for benign prostatic hyperplasia
BackgroundResistance of voiding symptoms to α1-blockers in benign prostatic hyperplasia (BPH) has been provisionally explained by non-adrenergic prostate smooth muscle contraction....
Ablation Performance of C/SiC-ZrC Composites
Ablation Performance of C/SiC-ZrC Composites
Abstract
To reveal the ablation performance of C/SiC-ZrC composites under different ablation methods, C/SiC-ZrC composites were prepared by chemical vapor deposition and pr...
Analysis during Sinus Rhythm and Ventricular Pacing of Reentry Circuit Isthmus Sites in Right Ventricular Cardiomyopathy
Analysis during Sinus Rhythm and Ventricular Pacing of Reentry Circuit Isthmus Sites in Right Ventricular Cardiomyopathy
Background: The entrainment mapping algorithm is used for ablation of ventricular tachycardia (VT) in right ventricular (RV) cardiomyopathy, but ablation at endocardial isthmus sit...