Javascript must be enabled to continue!
Capsular Ligament Function After Total Hip Arthroplasty
View through CrossRef
Background:
The hip joint capsule passively restrains extreme range of motion, protecting the native hip against impingement, dislocation, and edge-loading. We hypothesized that following total hip arthroplasty (THA), the reduced femoral head size impairs this protective biomechanical function.
Methods:
In cadavers, THA was performed through the acetabular medial wall, preserving the entire capsule, and avoiding the targeting of a particular surgical approach. Eight hips were examined. Capsular function was measured by rotating the hip in 5 positions. Three head sizes (28, 32, and 36 mm) with 3 neck lengths (anatomical 0, +5, and +10 mm) were compared.
Results:
Internal and external rotation range of motion increased following THA, indicating late engagement of the capsule and reduced biomechanical function (p < 0.05). Internal rotation was affected more than external. Increasing neck length reduced this hypermobility, while too much lengthening caused nonphysiological restriction of external rotation. Larger head sizes only slightly reduced hypermobility.
Conclusions:
Following THA, the capsular ligaments were unable to wrap around the reduced-diameter femoral head to restrain extreme range of motion. The posterior capsule was the most affected, indicating that native posterior capsule preservation is not advantageous, at least in the short term. Insufficient neck length could cause capsular dysfunction even if native ligament anatomy is preserved, while increased neck length could overtighten the anterior capsule.
Clinical Relevance:
Increased understanding of soft-tissue balancing following THA could help to prevent instability and improve early function. This study illustrates how head size and neck length influence the biomechanical function of the hip capsule in the early postoperative period.
Ovid Technologies (Wolters Kluwer Health)
Title: Capsular Ligament Function After Total Hip Arthroplasty
Description:
Background:
The hip joint capsule passively restrains extreme range of motion, protecting the native hip against impingement, dislocation, and edge-loading.
We hypothesized that following total hip arthroplasty (THA), the reduced femoral head size impairs this protective biomechanical function.
Methods:
In cadavers, THA was performed through the acetabular medial wall, preserving the entire capsule, and avoiding the targeting of a particular surgical approach.
Eight hips were examined.
Capsular function was measured by rotating the hip in 5 positions.
Three head sizes (28, 32, and 36 mm) with 3 neck lengths (anatomical 0, +5, and +10 mm) were compared.
Results:
Internal and external rotation range of motion increased following THA, indicating late engagement of the capsule and reduced biomechanical function (p < 0.
05).
Internal rotation was affected more than external.
Increasing neck length reduced this hypermobility, while too much lengthening caused nonphysiological restriction of external rotation.
Larger head sizes only slightly reduced hypermobility.
Conclusions:
Following THA, the capsular ligaments were unable to wrap around the reduced-diameter femoral head to restrain extreme range of motion.
The posterior capsule was the most affected, indicating that native posterior capsule preservation is not advantageous, at least in the short term.
Insufficient neck length could cause capsular dysfunction even if native ligament anatomy is preserved, while increased neck length could overtighten the anterior capsule.
Clinical Relevance:
Increased understanding of soft-tissue balancing following THA could help to prevent instability and improve early function.
This study illustrates how head size and neck length influence the biomechanical function of the hip capsule in the early postoperative period.
Related Results
Morphological characteristics of the Lisfranc ligament
Morphological characteristics of the Lisfranc ligament
Abstract
Background
This study aimed to clarify the morphological characteristics of the Lisfranc ligament and the plantar ligament.
Methods
Forty legs from 20 cadavers w...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Capsular ligaments provide a passive stabilizing force to protect the hip against edge loading
Capsular ligaments provide a passive stabilizing force to protect the hip against edge loading
Aims In the native hip, the hip capsular ligaments tighten at the limits of range of hip motion and may provide a passive stabilizing force to protect the hip against edge loading....
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract
Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fragility, with a 22% one...
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
AIM: To investigate the risk factors of perioperative transfusion in hip arthroplasty and to construct a nomogram model to predict the risk of transfusion. METHODS: A total of 120 ...
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
AbstractObjectiveTo describe disability in individuals with hip arthroplasty and its evolution over 2 years compared with that in the general population, and to compare the degree ...
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Aims Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic looseni...
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Abstract
Background Rotating hinged knee prosthesis is frequently used for certain indications. The indications and results for rotating hinge knee prosthesis in primary an...

