Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Dynamics of manual impaction instruments during total hip arthroplasty

View through CrossRef
AimsManual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies.MethodsPosterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.ResultsThe force vector of the mallet strike, relative to the introducer axis, was misaligned by an average of 18.1°, resulting in an average wasted strike energy of 6.1%. Furthermore, the mean strike offset was 19.8 mm from the centre of the introducer axis and the mallet face, relative to the introducer strike face, was misaligned by a mean angle of 15.2° from the introducer strike face.ConclusionThe direction of the impact vector in manual impaction lacks both accuracy and precision. There is an opportunity to improve this through more advanced impaction instruments or surgical training.Cite this article: Bone Joint Res 2024;13(4):193–200.
Title: Dynamics of manual impaction instruments during total hip arthroplasty
Description:
AimsManual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA).
This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component.
This understanding aims to help improve impaction surgical techniques and inform the development of future technologies.
MethodsPosterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon.
An instrumented mallet and introducer were used to insert cementless acetabular cups.
The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes.
Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment.
ResultsThe force vector of the mallet strike, relative to the introducer axis, was misaligned by an average of 18.
1°, resulting in an average wasted strike energy of 6.
1%.
Furthermore, the mean strike offset was 19.
8 mm from the centre of the introducer axis and the mallet face, relative to the introducer strike face, was misaligned by a mean angle of 15.
2° from the introducer strike face.
ConclusionThe direction of the impact vector in manual impaction lacks both accuracy and precision.
There is an opportunity to improve this through more advanced impaction instruments or surgical training.
Cite this article: Bone Joint Res 2024;13(4):193–200.

Related Results

Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fragility, with a 22% one...
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
AIM: To investigate the risk factors of perioperative transfusion in hip arthroplasty and to construct a nomogram model to predict the risk of transfusion. METHODS: A total of 120 ...
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
AbstractObjectiveTo describe disability in individuals with hip arthroplasty and its evolution over 2 years compared with that in the general population, and to compare the degree ...
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Aims Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic looseni...
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Abstract Background Rotating hinged knee prosthesis is frequently used for certain indications. The indications and results for rotating hinge knee prosthesis in primary an...
Clinical, hematological and biochemical findings in cattle suffering from rumen impaction in Libya
Clinical, hematological and biochemical findings in cattle suffering from rumen impaction in Libya
The present study was conducted on 32 cattle suffering from rumen impaction caused by plastic material as foreign body, admitted to the Veterinary Teaching Hospital, University of ...
Risk Factors Associated With Short-term Clinical Results After Total Hip Arthroplasty for Patients With Rheumatoid Arthritis
Risk Factors Associated With Short-term Clinical Results After Total Hip Arthroplasty for Patients With Rheumatoid Arthritis
Clinical outcomes of total hip arthroplasty for rheumatoid arthritis are reportedly worse than those of total hip arthroplasty for osteoarthritis of the hip. The authors examined p...

Back to Top