Javascript must be enabled to continue!
Parametric Analysis on Boil-Off Gas Rate inside Liquefied Natural Gas Storage Tank
View through CrossRef
Research into the environmental effect of greenhouse emissions is now intense. One of the sources contributing to the effect is boil-off gas (BOG) flaring into the atmosphere. BOG formation is caused by heat leakage from the liquefied natural gas (LNG) storage tank. Heat leakages are determined by the effectiveness of heat thermal transmittance of the structural tank and ambient condition. The objective of this present study is therefore to determine the relationship between heat thermal transmittance and ambient condition, and the boil-off rate for a specific 40,447m3 LNG tank size corresponding to a 160,000m3 LNG ship size. General estimations of the amounts of BOG generated are useful in determining the amount of BOG that will need to flare in order to control the greenhouse effect and the amount of pollution entering the environment. This study analyzes both the steady and unsteady behavior of heat transfer mechanisms using ANSYS Fluent software. Results show that dynamic transient simulation only takes effect on the first five days of a voyage. There is then a linear relationship between the investigated parameters of the boil-off rate of LNG. These linear relations are of the utmost use for LNG tank manufacturer and researchers requiring a preliminary view in order to determine LNG tank specification. The result obtained is also validated by studies by previous researcher.
Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press)
Title: Parametric Analysis on Boil-Off Gas Rate inside Liquefied Natural Gas Storage Tank
Description:
Research into the environmental effect of greenhouse emissions is now intense.
One of the sources contributing to the effect is boil-off gas (BOG) flaring into the atmosphere.
BOG formation is caused by heat leakage from the liquefied natural gas (LNG) storage tank.
Heat leakages are determined by the effectiveness of heat thermal transmittance of the structural tank and ambient condition.
The objective of this present study is therefore to determine the relationship between heat thermal transmittance and ambient condition, and the boil-off rate for a specific 40,447m3 LNG tank size corresponding to a 160,000m3 LNG ship size.
General estimations of the amounts of BOG generated are useful in determining the amount of BOG that will need to flare in order to control the greenhouse effect and the amount of pollution entering the environment.
This study analyzes both the steady and unsteady behavior of heat transfer mechanisms using ANSYS Fluent software.
Results show that dynamic transient simulation only takes effect on the first five days of a voyage.
There is then a linear relationship between the investigated parameters of the boil-off rate of LNG.
These linear relations are of the utmost use for LNG tank manufacturer and researchers requiring a preliminary view in order to determine LNG tank specification.
The result obtained is also validated by studies by previous researcher.
Related Results
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
The Challenges of Underground Hydrogen Gas Storage
The Challenges of Underground Hydrogen Gas Storage
ABSTRACT:
While hydrogen as a gas (H2) has been stored in salt caverns on the American Gulf Coast for the last 40 years, it’s attributes are a challenge for under...
Fracture Toughness Evaluation by Large-Scale Test Under Hydrogen Liquefaction Temperature
Fracture Toughness Evaluation by Large-Scale Test Under Hydrogen Liquefaction Temperature
Abstract
Hydrogen is one of the energy carriers envisioned for achieving a carbon-neutral society. Liquefied hydrogen can be transported in large quantities by ship ...
Analysis of Uneven Settlement of Large Oil Storage Tank
Analysis of Uneven Settlement of Large Oil Storage Tank
Abstract
The uneven settlement of large oil storage tank will not only cause the tank wall to be elliptical and the upper floating plate to be blocked, but also caus...
Tank Cleaning Process Optimization For Loading Tanks MT Bauhinia Guna Cargo Change
Tank Cleaning Process Optimization For Loading Tanks MT Bauhinia Guna Cargo Change
Suboptimal implementation of tank cleaning will produce suboptimal results and can affect loading failure. These less than optimal results are influenced by several things. Tank Cl...
Offshore Salt-Cavern-Based LNG Receiving Terminal
Offshore Salt-Cavern-Based LNG Receiving Terminal
Abstract
The global LNG business is in the early stages of a significant expansion. Predictions are that the volumes in the LNG industry will more than double in ...
Multi-Round Development of Underground Gas Storage Converted from Depleted Oil Reservoirs: Physical Properties Changes and Capacity Expansion
Multi-Round Development of Underground Gas Storage Converted from Depleted Oil Reservoirs: Physical Properties Changes and Capacity Expansion
ABSTRACT
This study analyzed the physical properties changes for natural cores under combined effects of alternating stress and multiple rounds of gas flushing. F...
An Economic Study of CNG Floating Processing and Storage Platform and the Supporting CNG Carriers
An Economic Study of CNG Floating Processing and Storage Platform and the Supporting CNG Carriers
Abstract
An Economic Study of CNG Floating Processing and Storage Platform and the CNG Carriers to support it are presentenced. There are many small (Stranded) ga...