Javascript must be enabled to continue!
Evaluation of Dry Textile Electrodes for Long-term Electrocardiographic Monitoring
View through CrossRef
Abstract
Background: Continuous long-term electrocardiography monitoring has been increasingly recognized for early diagnosis and management of different types of cardiovascular diseases. To find an alternative to Ag/AgCl gel electrodes that are improper for this application scenario, many efforts have been undertaken to develop novel flexible dry textile electrodes integrated into the everyday garments. With significant progresses made to address the potential issues (e.g., low signal to noise ratio, high skin-electrode impedance, motion artifact, and low durability), the lack of standard evaluation procedure hinders the further development of dry electrodes (mainly the design and optimization).Results: A standard testing procedure and framework for skin-electrode impedance measurement is demonstrated for the development of novel dry textile electrodes. Different representative electrode materials have been screen-printed on textile substrates. To verify the performance of dry textile electrodes, impedance measurements are conducted on an Agar skin model using a universal setup with consistent frequency and pressure. In addition, they are demonstrated for ECG signals acquisition, in comparison to those obtained using conventional gel electrodes.Conclusions: Dry textile electrodes demonstrated similar impedance when in raised or flat structures. The tested pressure variations had an insignificant impact on electrode impedance. Looking at the effect of impedance on ECG signals, a noticeable effect on ECG signal performance metrics was not observed. Therefore, it is suggested that impedance alone is possibly not the primary indicator of signal quality. As well, the developed methods can also serve as useful guidelines for future textile dry electrode design and testing for practical ECG monitoring applications.
Springer Science and Business Media LLC
Title: Evaluation of Dry Textile Electrodes for Long-term Electrocardiographic Monitoring
Description:
Abstract
Background: Continuous long-term electrocardiography monitoring has been increasingly recognized for early diagnosis and management of different types of cardiovascular diseases.
To find an alternative to Ag/AgCl gel electrodes that are improper for this application scenario, many efforts have been undertaken to develop novel flexible dry textile electrodes integrated into the everyday garments.
With significant progresses made to address the potential issues (e.
g.
, low signal to noise ratio, high skin-electrode impedance, motion artifact, and low durability), the lack of standard evaluation procedure hinders the further development of dry electrodes (mainly the design and optimization).
Results: A standard testing procedure and framework for skin-electrode impedance measurement is demonstrated for the development of novel dry textile electrodes.
Different representative electrode materials have been screen-printed on textile substrates.
To verify the performance of dry textile electrodes, impedance measurements are conducted on an Agar skin model using a universal setup with consistent frequency and pressure.
In addition, they are demonstrated for ECG signals acquisition, in comparison to those obtained using conventional gel electrodes.
Conclusions: Dry textile electrodes demonstrated similar impedance when in raised or flat structures.
The tested pressure variations had an insignificant impact on electrode impedance.
Looking at the effect of impedance on ECG signals, a noticeable effect on ECG signal performance metrics was not observed.
Therefore, it is suggested that impedance alone is possibly not the primary indicator of signal quality.
As well, the developed methods can also serve as useful guidelines for future textile dry electrode design and testing for practical ECG monitoring applications.
Related Results
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Commercial wet Silver and Silver Chloride electrodes are used to monitor electrocardiogram (ECG) signals in numerous bioimpedance applications. These electrodes are frequently sing...
Effects of binder and solvent on cathode manufacturing for Li-ion batteries
Effects of binder and solvent on cathode manufacturing for Li-ion batteries
Lithium-ion batteries (LIBs) have played a significant role in consumer electronics and electric vehicles. The major focus of research in Li-ion batteries has been to maximize perf...
Amalgam Electrodes for Electroanalysis
Amalgam Electrodes for Electroanalysis
AbstractLiquid mercury is a unique material for the indicator electrode in voltammetry. One reason for this is the high overvoltage for hydrogen formation, thus extending the actua...
Evaluation of preoperative dry eye in people undergoing corneal refractive surgery to correct myopia
Evaluation of preoperative dry eye in people undergoing corneal refractive surgery to correct myopia
AIM: To investigate the incidence of preoperative dry eye and related factors in patients undergoing corneal refractive surgery to correct myopia.
METHODS: A total of 141 patients ...
Psihološke odrednice sindroma suhog oka
Psihološke odrednice sindroma suhog oka
Introduction: Dry eye disease (DED) is a worldwide public health problem that may cause serious consequences for the patient's health. The etiology of the disease is multifactorial...
Chitosan-Catechol Modified Dopamine Sensor
Chitosan-Catechol Modified Dopamine Sensor
Dopamine is a neurotransmitter found in several deep structures of the brain. For example, in the ventral tegmental area (VTA) of the midbrain, in the substantia nigra pars compact...
Development of textile capacitive sensor
Development of textile capacitive sensor
(English) Nowadays, the textile clothing industry is searching for new ways to add value to their products. Developments in textile sensors
start to demonstrate their usability an...
Preliminary Study on Wearable Smart Socks with Hydrogel Electrodes for Surface Electromyography-Based Muscle Activity Assessment
Preliminary Study on Wearable Smart Socks with Hydrogel Electrodes for Surface Electromyography-Based Muscle Activity Assessment
Surface electromyography (sEMG) is increasingly important for prevention, diagnosis, and rehabilitation in healthcare. The continuous monitoring of muscle electrical activity enabl...