Javascript must be enabled to continue!
Concept and Evaluation of a New Piezoelectric Transducer for an Implantable Middle Ear Hearing Device
View through CrossRef
Implantable middle ear hearing devices (IMEHDs) have been developed as a new technology to overcome the limitations of conventional hearing aids. The piezoelectric cantilever transducers currently used in the IMEHDs have the advantages of low power consumption and ease of fabrication, but generate less high-frequency output. To address this problem, we proposed and designed a new piezoelectric transducer based on a piezoelectric stack for the IMEHD. This new transducer, attached to the incus body with a coupling rod, stimulates the ossicular chain in response to the expansion-and-contraction of its piezoelectric stack. To test its feasibility for hearing loss compensation, a bench testing of the transducer prototype and a temporal bone experiment were conducted, respectively. Bench testing results showed that the new transducer did have a broad frequency bandwidth. Besides, the transducer was found to have a low total harmonic distortion (<0.75%) in all frequencies, and small release time (1 ms). The temporal bone experiment further proved that the transducer has the capability to produce sufficient vibrations to compensate for severe sensorineural hearing loss, especially at high frequencies. This property benefits the treatment of the most common sloping high-frequency sensorineural hearing loss. To produce a 100 dB SPL equivalent sound pressure at 1 kHz, its power consumption is 0.49 mW, which is low enough for the transducer to be utilized in the IMEHD.
Title: Concept and Evaluation of a New Piezoelectric Transducer for an Implantable Middle Ear Hearing Device
Description:
Implantable middle ear hearing devices (IMEHDs) have been developed as a new technology to overcome the limitations of conventional hearing aids.
The piezoelectric cantilever transducers currently used in the IMEHDs have the advantages of low power consumption and ease of fabrication, but generate less high-frequency output.
To address this problem, we proposed and designed a new piezoelectric transducer based on a piezoelectric stack for the IMEHD.
This new transducer, attached to the incus body with a coupling rod, stimulates the ossicular chain in response to the expansion-and-contraction of its piezoelectric stack.
To test its feasibility for hearing loss compensation, a bench testing of the transducer prototype and a temporal bone experiment were conducted, respectively.
Bench testing results showed that the new transducer did have a broad frequency bandwidth.
Besides, the transducer was found to have a low total harmonic distortion (<0.
75%) in all frequencies, and small release time (1 ms).
The temporal bone experiment further proved that the transducer has the capability to produce sufficient vibrations to compensate for severe sensorineural hearing loss, especially at high frequencies.
This property benefits the treatment of the most common sloping high-frequency sensorineural hearing loss.
To produce a 100 dB SPL equivalent sound pressure at 1 kHz, its power consumption is 0.
49 mW, which is low enough for the transducer to be utilized in the IMEHD.
Related Results
Rhinitis-Respect your nose
Rhinitis-Respect your nose
We all know the functions of nose i.e. breathing and smell. The outcome of breathing is to ventilate the lungs and we also know that there is lung compliance which reflects its eff...
Prevention and Control Strategy
Prevention and Control Strategy
Ear diseases are considered as one of the common disorders in small animal
practice and the number one cause for veterinary visits among dog owners. Commonly
reported clinical sign...
Review of high temperature piezoelectric materials, devices, and applications
Review of high temperature piezoelectric materials, devices, and applications
Piezoelectric functional materials have been extensively studied and employed in numerous devices. With the rapid development of modern industries, such as power plants, aerospace,...
Analyzing the Relationship Between Real-Ear Measures, the Abbreviated Profile of Hearing Aid Benefit, and Hearing Aid Retention
Analyzing the Relationship Between Real-Ear Measures, the Abbreviated Profile of Hearing Aid Benefit, and Hearing Aid Retention
Purpose:
Hearing loss is one of the most common chronic conditions in adults aged 65 years or older. Despite the variety of hearing devices and services offered...
Pattern of hearing loss among patients visiting ENT OPD at Janaki Medical College: A cross sectional study
Pattern of hearing loss among patients visiting ENT OPD at Janaki Medical College: A cross sectional study
Background and Objectives: To study the pattern of hearing loss among patients visiting ENT OPD in Janaki medical college teaching hospital.Material and Methods: The study was cond...
Role of tympanocentesis in the prevention of middle ear barotrauma induced by fast buoyant ascent escape from 200 m underwater
Role of tympanocentesis in the prevention of middle ear barotrauma induced by fast buoyant ascent escape from 200 m underwater
Introduction: We aimed to study middle ear barotrauma caused by fast compression followed by buoyant ascent escape from 200 m underwater and its effect on the auditory system, and ...
Normal Structure and Function of Ears
Normal Structure and Function of Ears
Hearing is one of the fundamental sense. Ear also known as the
vestibulocochlear organ, is subdivided into three parts namely external, middle and
inner ear. Auricle and external a...
Real-ear Unaided Gain in Wrestlers with Unilateral Cauliflower Ear
Real-ear Unaided Gain in Wrestlers with Unilateral Cauliflower Ear
Background and Aim: Real-Ear Unaided Gain(REUG) can reveal the outer-ear resonance which reflects the effects of body and ear factors. Deformity in the outer ear may change the rea...

