Javascript must be enabled to continue!
The accuracy of anatomic landmarks on the occlusal plane: a comparative study between conventional and 3D image method
View through CrossRef
Abstract
Background
To establish the occlusal plane, the conventional methods for facial analysis to gain accurate alignment of the occlusal plane are inadequate, while 3D technologies are an ideal diagnostic tool. The aims of this research are to compare the difference accuracy of anatomic landmarks on the occlusal plane and ala-tragus line between the conventional clinical method and 3D image method in both non-orthodontic and orthodontic treatment volunteers.
Methods
A total of 44 volunteers (22 non-orthodontic and 22 orthodontic treatment volunteers) with normal occlusion were selected. All volunteers received 2 operative methods for occlusal plane determination. In conventional method, the occlusal plane was defined by the fox plane line. The ala-tragus line was defined by the radio-opaque markers. In the 3D image method, the volunteers were recorded intraoral images, 3D facial images and CBCT images. A 3D virtual picture was created using EXOCAD® software. The occlusal plane was generated by the incisal and occlusal surfaces of the teeth. Both methods, the angles and distances between the occlusal plane and ala-tragus line were measured and compared statistically on both sides of each volunteer.
Results
Both volunteers’ group, the mean angles and distances between the occlusal plane-ala tragus line in the conventional method were reported to be significantly greater than the 3D method (P < 0.05). The percentage difference of angles in conventional method were reported to be significantly higher by 13.61–21.58% (p < 0.05) compared to the 3D method. The percentage difference of distances in the conventional method were reported to be significantly greater than the 3D method by 4.73–7.51% (p < 0.05).
Conclusions
Within the limitation of the study, it can be concluded that both conventional and digital methods for establishing the occlusal plane are not parallel to the occlusal plane. The occlusal plane and ala-tragus line in the conventional method and the 3D method were significantly different in terms of angles and distances in both non-orthodontic and orthodontic treatment volunteers. However, the deviation angle of both methods is approximately 13–20 degrees, which is clinically acceptable for occlusal plane establishment. The accuracy of both methods is still within the using in clinical implementation.
Springer Science and Business Media LLC
Title: The accuracy of anatomic landmarks on the occlusal plane: a comparative study between conventional and 3D image method
Description:
Abstract
Background
To establish the occlusal plane, the conventional methods for facial analysis to gain accurate alignment of the occlusal plane are inadequate, while 3D technologies are an ideal diagnostic tool.
The aims of this research are to compare the difference accuracy of anatomic landmarks on the occlusal plane and ala-tragus line between the conventional clinical method and 3D image method in both non-orthodontic and orthodontic treatment volunteers.
Methods
A total of 44 volunteers (22 non-orthodontic and 22 orthodontic treatment volunteers) with normal occlusion were selected.
All volunteers received 2 operative methods for occlusal plane determination.
In conventional method, the occlusal plane was defined by the fox plane line.
The ala-tragus line was defined by the radio-opaque markers.
In the 3D image method, the volunteers were recorded intraoral images, 3D facial images and CBCT images.
A 3D virtual picture was created using EXOCAD® software.
The occlusal plane was generated by the incisal and occlusal surfaces of the teeth.
Both methods, the angles and distances between the occlusal plane and ala-tragus line were measured and compared statistically on both sides of each volunteer.
Results
Both volunteers’ group, the mean angles and distances between the occlusal plane-ala tragus line in the conventional method were reported to be significantly greater than the 3D method (P < 0.
05).
The percentage difference of angles in conventional method were reported to be significantly higher by 13.
61–21.
58% (p < 0.
05) compared to the 3D method.
The percentage difference of distances in the conventional method were reported to be significantly greater than the 3D method by 4.
73–7.
51% (p < 0.
05).
Conclusions
Within the limitation of the study, it can be concluded that both conventional and digital methods for establishing the occlusal plane are not parallel to the occlusal plane.
The occlusal plane and ala-tragus line in the conventional method and the 3D method were significantly different in terms of angles and distances in both non-orthodontic and orthodontic treatment volunteers.
However, the deviation angle of both methods is approximately 13–20 degrees, which is clinically acceptable for occlusal plane establishment.
The accuracy of both methods is still within the using in clinical implementation.
Related Results
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Relationship of natural occlusal plane with different anatomical landmarks
Relationship of natural occlusal plane with different anatomical landmarks
Abstract
Objectives: To evaluate the parallelism of natural maxillary occlusal plane with inter-pupillary line and ala-tragus line among dentate subjects.
To evaluate anatomic rela...
CAD‐CAM and analog occlusal splints comparison based on the amount of occlusal adjustments. 3D analysis of the volumetric changes: A pilot study
CAD‐CAM and analog occlusal splints comparison based on the amount of occlusal adjustments. 3D analysis of the volumetric changes: A pilot study
AbstractObjectiveTo evaluate the volumetric changes on occlusal surface of computer‐aided design and computer‐aided manufacturing (CAD‐CAM) occlusal devices fabricated following a ...
Landmark-based geometric morphometrics: Influential landmarks
Landmark-based geometric morphometrics: Influential landmarks
Abstract
Geometric morphometrics based on two-dimensional landmarks is a powerful tool for distinguishing morphologically similar or cryptic taxa, an important asse...
Accuracy of Cone Beam CT Measurements for Assessment of Posterior Mandible: A Cadaver Study
Accuracy of Cone Beam CT Measurements for Assessment of Posterior Mandible: A Cadaver Study
Objectives: This study is aimed at analysing the accuracy and reliability of the cone beam CT (CBCT) measurements and direct physical measurements of the posterior mandible.
Mater...
Double Exposure
Double Exposure
I. Happy Endings
Chaplin’s Modern Times features one of the most subtly strange endings in Hollywood history. It concludes with the Tramp (Chaplin) and the Gamin (Paulette Godda...
Standards and Specifications in Pathology: Image Management, Report Management and Terminology
Standards and Specifications in Pathology: Image Management, Report Management and Terminology
For making medical decisions, healthcare professionals require that all necessary information is both correct and easily available. Collaborative Digital Anatomic Pathology refers ...
Temporomandibular Disorders in Patients with Occlusal Interferences
Temporomandibular Disorders in Patients with Occlusal Interferences
Objective: To assess the temporomandibular disorders among patients with occlusal interferences.
Study Design: Cross-sectional study.
Place and Duration of Study: Prost...

