Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Correlation Between Implant Stability Quotient and Percussion Sound Frequency

View through CrossRef
ABSTRACTObjectivesTo determine the correlation between the primary implant stability quotient and the implant percussion sound frequency.Materials and MethodsA total of 14 pigs' ribs were scanned using a dental cone beam computed tomography (CBCT) scanner to classify the bone specimens into three distinct bone density Hounsfield units (HU) value categories: D1 bone: >1250 HU; D2: 850–1250 HU; D3: <850 HU. Then, 96 implants were inserted: 32 implants in D1 bone, 32 implants in D2 bone, and 32 implants in D3 bone. The primary implant stability quotient (ISQ) was analyzed, and percussion sound was recorded using a wireless microphone connected and analyzed with frequency analysis software.ResultsStatistically significant positive correlations were found between the primary ISQ and the bone density HU value (r = 0.719; p < 0.001), and statistically significant positive correlations between the primary ISQ and the percussion sound frequency (r = 0.606; p < 0.001). Furthermore, significant differences in primary ISQ values and percussion sound frequency were found between D1 and D2 bone, as well as between D1 and D3 bone. However, no significant differences were found in primary ISQ values and percussion sound frequency between D2 and D3 bone.ConclusionThe primary ISQ value and the percussion sound frequency are positively correlated.
Title: Correlation Between Implant Stability Quotient and Percussion Sound Frequency
Description:
ABSTRACTObjectivesTo determine the correlation between the primary implant stability quotient and the implant percussion sound frequency.
Materials and MethodsA total of 14 pigs' ribs were scanned using a dental cone beam computed tomography (CBCT) scanner to classify the bone specimens into three distinct bone density Hounsfield units (HU) value categories: D1 bone: >1250 HU; D2: 850–1250 HU; D3: <850 HU.
Then, 96 implants were inserted: 32 implants in D1 bone, 32 implants in D2 bone, and 32 implants in D3 bone.
The primary implant stability quotient (ISQ) was analyzed, and percussion sound was recorded using a wireless microphone connected and analyzed with frequency analysis software.
ResultsStatistically significant positive correlations were found between the primary ISQ and the bone density HU value (r = 0.
719; p < 0.
001), and statistically significant positive correlations between the primary ISQ and the percussion sound frequency (r = 0.
606; p < 0.
001).
Furthermore, significant differences in primary ISQ values and percussion sound frequency were found between D1 and D2 bone, as well as between D1 and D3 bone.
However, no significant differences were found in primary ISQ values and percussion sound frequency between D2 and D3 bone.
ConclusionThe primary ISQ value and the percussion sound frequency are positively correlated.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Influence of implant design, length, diameter, and anatomic region on implant stability: a randomized clinical trial
Influence of implant design, length, diameter, and anatomic region on implant stability: a randomized clinical trial
Objectives: To evaluate the influence of implant geometry and anatomical region on implant stability. Methods: A randomized controlled clinical trial was conducted on 45 patients, ...
REUSE OF THE INTRAOSSEOUS PART OF THE DENTAL IMPLANT (THE CLINICAL CASE)
REUSE OF THE INTRAOSSEOUS PART OF THE DENTAL IMPLANT (THE CLINICAL CASE)
Introduction. Replacement of a small included defect in the frontal area with a fixed structure based on the implant is the optimal solution. It is not always required to remove th...
Evaluation of hybrid implant in posterior edentulous maxilla with inadequate bone
Evaluation of hybrid implant in posterior edentulous maxilla with inadequate bone
Aim of this study is to investigate.Hybrid implant has got satisfactory results in our previous study in various edentulous areas with inadequate bone for endosseous implant placem...

Back to Top