Javascript must be enabled to continue!
Intraocular correction of presbyopia after laser keratorefractive surgery
View through CrossRef
Purpose. To present the results of research on modern aspects of intraocular correction of presbyopia after laser keratorefractive surgery. Material and methods. A literature search was performed to identify studies on databases eLibrary, PubMed and Scopus, using the keywords «calculation of multifocal lenses», «multifocal IOLs after refractive surgery», «correction of presbyopia after refractive surgery» (in the eLibrary database), «multifocal IOL» and «multifocal lenses calculation» (in the PubMed and Scopus databases). Thirty related articles were identified. In addition, seven clinical studies in which different groups of patients with a history of refractive surgery underwent correction of presbyopia with multifocal intraocular lenses (IOL) were identified. Results. In this article, there are examples of recent research of information about the intricacies of calculating refractive power of multifocal lenses after refractive surgery. Every year the number of people with a history of laser vision correction is growing, which means that for surgeons arises question about correct calculation of keratometric parameters. To date, the calculation of the value of the optical power of an implantable multifocal IOL after laser refractive surgery is complex and individual for each patient. Most people in this category are still not ready to wear glasses. Recent studies confirm the success of calculating implantable multifocal IOL, and ways to minimize inaccuracies in hitting the refraction of the target lie both in the approach to calculating the optical power of an implanted multifocal lens, and in choosing the optimal method for assessing artificially modified cornea keratometry. Conclusion. The results of clinical studies presented in the review allow us to conclude that the results of calculating the optical power of implanted multifocal IOLs are quite successful and, in turn, clinical and functional results in patients with a history of laser refractive surgery. However, further research is required. Key words: presbyopia correction, multifocal IOL, IOL calculation formulas, laser correction, LASIK, FemtoLASIK, SMILE.
Title: Intraocular correction of presbyopia after laser keratorefractive surgery
Description:
Purpose.
To present the results of research on modern aspects of intraocular correction of presbyopia after laser keratorefractive surgery.
Material and methods.
A literature search was performed to identify studies on databases eLibrary, PubMed and Scopus, using the keywords «calculation of multifocal lenses», «multifocal IOLs after refractive surgery», «correction of presbyopia after refractive surgery» (in the eLibrary database), «multifocal IOL» and «multifocal lenses calculation» (in the PubMed and Scopus databases).
Thirty related articles were identified.
In addition, seven clinical studies in which different groups of patients with a history of refractive surgery underwent correction of presbyopia with multifocal intraocular lenses (IOL) were identified.
Results.
In this article, there are examples of recent research of information about the intricacies of calculating refractive power of multifocal lenses after refractive surgery.
Every year the number of people with a history of laser vision correction is growing, which means that for surgeons arises question about correct calculation of keratometric parameters.
To date, the calculation of the value of the optical power of an implantable multifocal IOL after laser refractive surgery is complex and individual for each patient.
Most people in this category are still not ready to wear glasses.
Recent studies confirm the success of calculating implantable multifocal IOL, and ways to minimize inaccuracies in hitting the refraction of the target lie both in the approach to calculating the optical power of an implanted multifocal lens, and in choosing the optimal method for assessing artificially modified cornea keratometry.
Conclusion.
The results of clinical studies presented in the review allow us to conclude that the results of calculating the optical power of implanted multifocal IOLs are quite successful and, in turn, clinical and functional results in patients with a history of laser refractive surgery.
However, further research is required.
Key words: presbyopia correction, multifocal IOL, IOL calculation formulas, laser correction, LASIK, FemtoLASIK, SMILE.
Related Results
Comparison of total corneal power measurements obtained with different devices after myopic keratorefractive surgery
Comparison of total corneal power measurements obtained with different devices after myopic keratorefractive surgery
AIM: To analyze the differences, agreements, and correlation among total corneal power parameters generated by different instruments after myopic keratorefractive surgery.
METHODS:...
Automated Detection of Keratorefractive Laser Surgeries on Optical Coherence Tomography using Deep Learning
Automated Detection of Keratorefractive Laser Surgeries on Optical Coherence Tomography using Deep Learning
ABSTRACTPURPOSETo report a deep learning neural network on anterior segment optical coherence tomography (AS-OCT) for automated detection of different keratorefractive laser surger...
Impact of Uncorrected Presbyopia on quality of life among individuals of urban slums of Lahore
Impact of Uncorrected Presbyopia on quality of life among individuals of urban slums of Lahore
Purpose: To assess the impact on quality of life after presbyopia correction among the general population, and draw attention to a huge public health issue.
Methods: This cross...
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
In recent years, more than 90% of the signal laser power can be up-converted based on the high-efficiency double resonant external cavity sum-frequency generation (SFG), especially...
Correlation between presbyopia, age and number of births of mothers in the Kumasi area of Ghana
Correlation between presbyopia, age and number of births of mothers in the Kumasi area of Ghana
Summary
There is an assumption in Ghana that motherhood has an effect on presbyopia. This study thus attempts to correlate the relationship between presbyopia, ag...
Excimer Laser Micromachining of MEMS Materials
Excimer Laser Micromachining of MEMS Materials
Conventional photolithography-based microfabrication techniques are limited to two-dimensional fabrication and only particular materials can be used. Excimer laser micromachining e...
Laser show safety for smaller shows: The ILDA category a laser show standard
Laser show safety for smaller shows: The ILDA category a laser show standard
The International Laser Display Association has developed a “Category A Standard” for laser shows that ILDA considers to be generally recognized as safe under the conditions of the...
Dual Laser Method for Experimentally Weathering Planetary Regoliths
Dual Laser Method for Experimentally Weathering Planetary Regoliths
<p>Experimental space weathering&#8212;whether laser, thermal reduction, impact, or ion based&#8212;is a critical endeavor to accurately interpret spa...

