Javascript must be enabled to continue!
Tuning Microelectrodes’ Impedance to Improve Fast Ripples Recording
View through CrossRef
Epilepsy is a chronic neurological disorder characterized by recurrent seizures resulting from abnormal neuronal hyperexcitability. In the case of pharmacoresistant epilepsy requiring resection surgery, the identification of the Epileptogenic Zone (EZ) is critical. Fast Ripples (FRs; 200–600 Hz) are one of the promising biomarkers that can aid in EZ delineation. However, recording FRs requires physically small electrodes. These microelectrodes suffer from high impedance, which significantly impacts FRs’ observability and detection. In this study, we investigated the potential of a conductive polymer coating to enhance FR observability. We employed biophysical modeling to compare two types of microelectrodes: Gold (Au) and Au coated with the conductive polymer poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) (Au/PEDOT:PSS). These electrodes were then implanted into the CA1 hippocampal neural network of epileptic mice to record FRs during epileptogenesis. The results showed that the polymer-coated electrodes had a two-order lower impedance as well as a higher transfer function amplitude and cut-off frequency. Consequently, FRs recorded with the PEDOT:PSS-coated microelectrode yielded significantly higher signal energy compared to the uncoated one. The PEDOT:PSS coating improved the observability of the recorded FRs and thus their detection. This work paves the way for the development of signal-specific microelectrode designs that allow for better targeting of pathological biomarkers.
Title: Tuning Microelectrodes’ Impedance to Improve Fast Ripples Recording
Description:
Epilepsy is a chronic neurological disorder characterized by recurrent seizures resulting from abnormal neuronal hyperexcitability.
In the case of pharmacoresistant epilepsy requiring resection surgery, the identification of the Epileptogenic Zone (EZ) is critical.
Fast Ripples (FRs; 200–600 Hz) are one of the promising biomarkers that can aid in EZ delineation.
However, recording FRs requires physically small electrodes.
These microelectrodes suffer from high impedance, which significantly impacts FRs’ observability and detection.
In this study, we investigated the potential of a conductive polymer coating to enhance FR observability.
We employed biophysical modeling to compare two types of microelectrodes: Gold (Au) and Au coated with the conductive polymer poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) (Au/PEDOT:PSS).
These electrodes were then implanted into the CA1 hippocampal neural network of epileptic mice to record FRs during epileptogenesis.
The results showed that the polymer-coated electrodes had a two-order lower impedance as well as a higher transfer function amplitude and cut-off frequency.
Consequently, FRs recorded with the PEDOT:PSS-coated microelectrode yielded significantly higher signal energy compared to the uncoated one.
The PEDOT:PSS coating improved the observability of the recorded FRs and thus their detection.
This work paves the way for the development of signal-specific microelectrode designs that allow for better targeting of pathological biomarkers.
Related Results
Cross-strataco-occurrence of ripples with theta-frequency oscillations in the hippocampus of foraging rats
Cross-strataco-occurrence of ripples with theta-frequency oscillations in the hippocampus of foraging rats
AbstractBackground and motivationBrain rhythms have been postulated to play central roles in animal cognition. A prominently reported dichotomy of hippocampal rhythms, driven prima...
Emergent Dynamics of Fast Ripples in the Epileptic Hippocampus
Emergent Dynamics of Fast Ripples in the Epileptic Hippocampus
Fast ripples are a type of transient high-frequency oscillations recorded from the epileptogenic regions of the hippocampus and the temporal cortex of epileptic humans and rodents....
Tuning Microelectrodes Impedance to Improve Fast Ripples Recording
Tuning Microelectrodes Impedance to Improve Fast Ripples Recording
Epilepsy is a chronic neurological disorder characterized by recurring seizures resulting from abnormal neuronal hyperexcitability. In the case of pharmacoresistant epilepsy requir...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Impedance -based Stability Analysis on IBR Integrated Power System
Impedance -based Stability Analysis on IBR Integrated Power System
<p dir="ltr">This thesis examines the small-signal stability of inverter-based resources (IBRs) in a power system that contains grid-forming inverters (GFMs) using impedance-...
Improving Fast Ripples Recording with Model-Guided Design of Microelectrodes
Improving Fast Ripples Recording with Model-Guided Design of Microelectrodes
<p>Objective: Microelectrodes allow for the recording of neural activities with a high spatial resolution. However, their small sizes result in their high impedance, therefor...
Improving Fast Ripples Recording with Model-Guided Design of Microelectrodes
Improving Fast Ripples Recording with Model-Guided Design of Microelectrodes
<p>Objective: Microelectrodes allow for the recording of neural activities with a high spatial resolution. However, their small sizes result in their high impedance, therefor...