Javascript must be enabled to continue!
Soft-Tissue Management Dental Implants with Digitally Customized Healing Abutments: A Pilot Study
View through CrossRef
Background: This pilot study aimed to evaluate the effectiveness of digitally crafted customized healing abutments in stabilizing peri-implant soft tissues following tooth extraction and assess the preservation of peri-implant soft tissue architecture over 5 years. Material and Methods: Forty patients (age ≥ 25 years) were divided into test (n = 20) and control (n = 20) groups. The test group received dental implants with immediate loading after tooth extraction, along with customized healing abutments fabricated using CAD/CAM technology. The control group received dental implants with immediate loading without customized healing abutments. The primary outcome was the change in distance between the peri-implant soft tissue margin and implant fixture surface from baseline to 5 years post implantation. Results: In the test group, there was a significant decrease in the distance between the peri-implant soft tissue margin and fixture surface from baseline to 5 years (p < 0.001), with pairwise comparisons showing significant differences between multiple time points (p < 0.05). The control group showed less pronounced changes over time. Conclusions: Within the limitations of this pilot study, digitally fabricated customized healing abutments appear effective in stabilizing peri-implant soft tissues and preserving soft tissue architecture around dental implants over 5 years following immediate implant placement. Randomized controlled trials are needed to confirm these findings.
Title: Soft-Tissue Management Dental Implants with Digitally Customized Healing Abutments: A Pilot Study
Description:
Background: This pilot study aimed to evaluate the effectiveness of digitally crafted customized healing abutments in stabilizing peri-implant soft tissues following tooth extraction and assess the preservation of peri-implant soft tissue architecture over 5 years.
Material and Methods: Forty patients (age ≥ 25 years) were divided into test (n = 20) and control (n = 20) groups.
The test group received dental implants with immediate loading after tooth extraction, along with customized healing abutments fabricated using CAD/CAM technology.
The control group received dental implants with immediate loading without customized healing abutments.
The primary outcome was the change in distance between the peri-implant soft tissue margin and implant fixture surface from baseline to 5 years post implantation.
Results: In the test group, there was a significant decrease in the distance between the peri-implant soft tissue margin and fixture surface from baseline to 5 years (p < 0.
001), with pairwise comparisons showing significant differences between multiple time points (p < 0.
05).
The control group showed less pronounced changes over time.
Conclusions: Within the limitations of this pilot study, digitally fabricated customized healing abutments appear effective in stabilizing peri-implant soft tissues and preserving soft tissue architecture around dental implants over 5 years following immediate implant placement.
Randomized controlled trials are needed to confirm these findings.
Related Results
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Root fractures are relatively uncommon compared to other types of dental traumas. It is sometimes extremely difficult for practitioners to decide what should be done and which appr...
Guest Editorial
Guest Editorial
Dental caries is one of the major health problems in Indonesia. Data from Indonesian Basic Health Research in 2013, 2015 and 2018 showed a consistent increase in the prevalence of ...
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia i...
Comparative Desensitization Effect of Vital Abutments Realized by Different Methods
Comparative Desensitization Effect of Vital Abutments Realized by Different Methods
Vital abutments presents different degree of dentinal sensitivity (DS) after their preparation. Protective methods of dentinal wound have the purpose to fill up the dentinal tubule...
Experimental Evaluation of Dental Implant Biomechanics Given Certain Stages of the Fixing Substrate Deterioration by Video Image Correlation Method
Experimental Evaluation of Dental Implant Biomechanics Given Certain Stages of the Fixing Substrate Deterioration by Video Image Correlation Method
Abstract
Background: Dental implants are useful tools and represent a widely spread technique for oral rehabilitation. Their long standingness is ...
DENTAL IMPLANTATION AS A METHOD OF OPTIMIZING TREATMENT OF PATIENTS WITH COMPLETE DENTAL TEETH
DENTAL IMPLANTATION AS A METHOD OF OPTIMIZING TREATMENT OF PATIENTS WITH COMPLETE DENTAL TEETH
The development of dentistry at the present stage opens up new possibilities in the treatment of adentia by intraosseous implantation of artificial supports for dentures, which ope...
Impact of Dental and Zygomatic Implants on Stress Distribution in Maxillary Defects: A 3-Dimensional Finite Element Analysis Study
Impact of Dental and Zygomatic Implants on Stress Distribution in Maxillary Defects: A 3-Dimensional Finite Element Analysis Study
The aim of this study was to evaluate the stress distribution in the bone around dental and zygomatic implants for 4 different implant-supported obturator prostheses designs in a u...

