Javascript must be enabled to continue!
A Gated, Four-frame Pinhole Camera with Quantitative Image Acquisition
View through CrossRef
A gated, multiframe microchannel plate soft X-ray sensor with quantitative acquisition has been developed. The system is composed of an image acquisition system and a gated pinhole camera capable of taking four successive frames at a time resolution of ∼220 ps. The response of the system has been quantitatively investigated. To perform a quantitative evaluation of the captured X-ray images, the image acquisition and measurement of the phosphor current are executed simultaneously in the experiment. The system has been examined using a plasma X-ray source generated by a plasma focus device with an additional gas puff. The compression and bifurcation process of plasma hot spots in a neon puffed experiment has been successfully recorded. Quantitative analysis of the images indicates that an order of 1016photons/(s·mm2·mrad2) emissions originate from the plasma in a soft X-ray region 6–14 Å.
Title: A Gated, Four-frame Pinhole Camera with Quantitative Image Acquisition
Description:
A gated, multiframe microchannel plate soft X-ray sensor with quantitative acquisition has been developed.
The system is composed of an image acquisition system and a gated pinhole camera capable of taking four successive frames at a time resolution of ∼220 ps.
The response of the system has been quantitatively investigated.
To perform a quantitative evaluation of the captured X-ray images, the image acquisition and measurement of the phosphor current are executed simultaneously in the experiment.
The system has been examined using a plasma X-ray source generated by a plasma focus device with an additional gas puff.
The compression and bifurcation process of plasma hot spots in a neon puffed experiment has been successfully recorded.
Quantitative analysis of the images indicates that an order of 1016photons/(s·mm2·mrad2) emissions originate from the plasma in a soft X-ray region 6–14 Å.
Related Results
Machine learning techniques for forensic camera model identification and anti-forensic attacks
Machine learning techniques for forensic camera model identification and anti-forensic attacks
The goal of camera model identification is to determine the manufacturer and model of an image's source camera. Camera model identification is an important task in multimedia foren...
X-ray induced pinhole closure in point-projection x-ray radiography
X-ray induced pinhole closure in point-projection x-ray radiography
In pinhole-assisted point-projection x-ray radiography (or “backlighting”), pinholes are placed between the sample of interest and an x-ray source (or “backlighter”) to effectively...
Evaluation of coronary arteries in congenital heart disease
in children: diagnostic comparison of electrocardiogram-gated and non-electrocardiogram-gated computed tomography cardiac angiography
Evaluation of coronary arteries in congenital heart disease
in children: diagnostic comparison of electrocardiogram-gated and non-electrocardiogram-gated computed tomography cardiac angiography
IntroductionTo compare the visualization and anatomy of coronary arteries in children (≤ 2 years) with congenital heart disease (CHD) on non-electrocardiogram (ECG)-gated and ECG-g...
A confocal profilometer using microlens arrays
A confocal profilometer using microlens arrays
Confocal reflected light microscopy provides a very high depth resolution if the numerical aperture of the micro-objective is on the order of 1. The most common confocal microscope...
PR-469-173823-R01 In Line Inspection and Evaluation of Pinholes in Oil and Gas Pipelines
PR-469-173823-R01 In Line Inspection and Evaluation of Pinholes in Oil and Gas Pipelines
Pinhole leaks have been reported as a significant cause of oil and gas pipeline failures in recent years. From 2010 to 2015, at least 131 significant incidents involving oil and ga...
PR-469-173823-R02 In-Line Inspection and Evaluation of Pinholes in Oil and Gas Pipelines - Phase II
PR-469-173823-R02 In-Line Inspection and Evaluation of Pinholes in Oil and Gas Pipelines - Phase II
Pinhole leaks have been reported as a significant cause of oil and gas pipeline failures in recent years. From 2010 to 2015, at least 131 significant incidents involving oil and ga...
Feasibility Study of Pinhole Inspection via Magnetic Flux Leakage and Hydrostatic Testing in Oil & Gas Pipelines
Feasibility Study of Pinhole Inspection via Magnetic Flux Leakage and Hydrostatic Testing in Oil & Gas Pipelines
Abstract
Oil & Gas pipeline pinhole leaks are more likely to lead to serious consequences than larger leaks because they are difficult to discover through conven...
Comparing Measurements of Sun-Earth Distance: Shadow Method and Two Pinhole Method Variations
Comparing Measurements of Sun-Earth Distance: Shadow Method and Two Pinhole Method Variations
This study compares three methods, one using a newly derived formula (the shadow method) and two conventionally used (the plate pinhole method and tube pinhole method), regarding t...