Importance of addressing National Electrical Code® violations that result in unusual exposure to 60 Hz magnetic fields
View through CrossRef
AbstractWe evaluated wiring in multifamily developments containing National Electrical Code® (NEC®) violations as a source of unusual exposure to 60 Hz magnetic fields. Two methods were used in this evaluation: measurement and modeling. We measured the building wiring as a source of magnetic fields in six multifamily developments in Michigan. In this small sample, building wiring proved to be an important source of exposure in four of the six cases. In all four cases with exposure from building wiring, one or more NEC violations were involved. To supplement our measurement efforts, we used computer modeling to compare magnetic field exposure due to building wiring with magnetic field exposure from external power lines. Our calculations showed that where the building wiring has a NEC violation leading to net current loops, the exposure due to wiring is likely to be more important than that from external power lines. Our results support the results obtained in a recent study of the exposure of Californian K‐12 students to magnetic fields, where building wiring with one or more NEC violation was found to be the single most important exposure source. If 60 Hz magnetic fields are important to avoid, then improved enforcement of the NEC, as required by law, is perhaps the single most important mitigation policy to adopt. Bioelectromagnetics 25:102–106, 2004. © 2004 Wiley‐Liss, Inc.
Title: Importance of addressing National Electrical Code® violations that result in unusual exposure to 60 Hz magnetic fields
Description:
AbstractWe evaluated wiring in multifamily developments containing National Electrical Code® (NEC®) violations as a source of unusual exposure to 60 Hz magnetic fields.
Two methods were used in this evaluation: measurement and modeling.
We measured the building wiring as a source of magnetic fields in six multifamily developments in Michigan.
In this small sample, building wiring proved to be an important source of exposure in four of the six cases.
In all four cases with exposure from building wiring, one or more NEC violations were involved.
To supplement our measurement efforts, we used computer modeling to compare magnetic field exposure due to building wiring with magnetic field exposure from external power lines.
Our calculations showed that where the building wiring has a NEC violation leading to net current loops, the exposure due to wiring is likely to be more important than that from external power lines.
Our results support the results obtained in a recent study of the exposure of Californian K‐12 students to magnetic fields, where building wiring with one or more NEC violation was found to be the single most important exposure source.
If 60 Hz magnetic fields are important to avoid, then improved enforcement of the NEC, as required by law, is perhaps the single most important mitigation policy to adopt.
Bioelectromagnetics 25:102–106, 2004.
© 2004 Wiley‐Liss, Inc.
Related Results
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Joint Beamforming and Aerial IRS Positioning Design for IRS-assisted MISO System with Multiple Access Points
Joint Beamforming and Aerial IRS Positioning Design for IRS-assisted MISO System with Multiple Access Points
<p><code>Intelligent reflecting surface (IRS) is a promising concept for </code><code><u>6G</u></code><code> wireless communications...
Joint Beamforming and Aerial IRS Positioning Design for IRS-assisted MISO System with Multiple Access Points
Joint Beamforming and Aerial IRS Positioning Design for IRS-assisted MISO System with Multiple Access Points
<p><code>Intelligent reflecting surface (IRS) is a promising concept for </code><code><u>6G</u></code><code> wireless communications...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Localized nanoscale induction by single domain magnetic particles
Localized nanoscale induction by single domain magnetic particles
AbstractSingle domain magnetic nanoparticles are increasingly investigated as actuators of biological and chemical processes that respond to externally applied magnetic fields. Alt...
Design of Malicious Code Detection System Based on Binary Code Slicing
Design of Malicious Code Detection System Based on Binary Code Slicing
<p>Malicious code threatens the safety of computer systems. Researching malicious code design techniques and mastering code behavior patterns are the basic work of network se...
Alih Kode Dan Campur Kode Dalam Interaksi Masyarakat Terminal Motabuik Kota Atambua
Alih Kode Dan Campur Kode Dalam Interaksi Masyarakat Terminal Motabuik Kota Atambua
This research aims to describe the use of language in community interactions at the Motabuik terminal, Atambua City. The use of language in question is the form and function of cod...
Systematic Evaluation of AI-Generated Python Code: A Comparative Study across Progressive Programming Tasks
Systematic Evaluation of AI-Generated Python Code: A Comparative Study across Progressive Programming Tasks
Abstract
Background: AI-based code assistants are on the rise in software development as powerful technologies offering streamlining of code generation and better-quality c...