Comparison of Ocular Lubricant Osmolalities

View through CrossRef
ABSTRACT Purpose The aim of this study was to evaluate the osmolality of commercially available ocular tear lubricants. Methods Thirty‐seven (n = 37) ocular lubricants, measured three times each, were evaluated for osmolality using a vapor pressure osmometer (Wescor VAPRO 5520). The osmometer was calibrated before each use, and the order of the lubricants was randomized. Ambient temperature and humidity were monitored for stability. Results Of the 37 ocular lubricants tested, 35 (94.6%) had an osmolality of less than 295 mmol/kg, one (2.7%) had between 295 and 308 mmol/kg, and one (2.7%) had more than 308 mmol/kg. The ambient room temperature was stable and ranged from 21.9°C to 22.0°C, and the relative humidity ranged from 21.2% to 25.6% during experimentation. When ocular lubricants were grouped by ingredient (carboxymethylcellulose and hydroxylpropyl methylcellulose, hyaluronic acid, and hydroxypropyl guar), no significant difference in osmolality was noted between groups (Mann‐Whitney U test, P >. 05). Conclusions The majority of the ocular lubricants tested had low osmolalities, mimicking the osmolarity of newly formed tears (295 to 300 mOsm/L). Several factors need to be considered when choosing a tear lubricant, which have more complex formulations than ever. Knowledge of their osmolality may be an added parameter to consider when choosing therapeutic options for dry eye.
Title: Comparison of Ocular Lubricant Osmolalities
Description:
ABSTRACT Purpose The aim of this study was to evaluate the osmolality of commercially available ocular tear lubricants.
Methods Thirty‐seven (n = 37) ocular lubricants, measured three times each, were evaluated for osmolality using a vapor pressure osmometer (Wescor VAPRO 5520).
The osmometer was calibrated before each use, and the order of the lubricants was randomized.
Ambient temperature and humidity were monitored for stability.
Results Of the 37 ocular lubricants tested, 35 (94.
6%) had an osmolality of less than 295 mmol/kg, one (2.
7%) had between 295 and 308 mmol/kg, and one (2.
7%) had more than 308 mmol/kg.
The ambient room temperature was stable and ranged from 21.
9°C to 22.
0°C, and the relative humidity ranged from 21.
2% to 25.
6% during experimentation.
When ocular lubricants were grouped by ingredient (carboxymethylcellulose and hydroxylpropyl methylcellulose, hyaluronic acid, and hydroxypropyl guar), no significant difference in osmolality was noted between groups (Mann‐Whitney U test, P >.
05).
Conclusions The majority of the ocular lubricants tested had low osmolalities, mimicking the osmolarity of newly formed tears (295 to 300 mOsm/L).
Several factors need to be considered when choosing a tear lubricant, which have more complex formulations than ever.
Knowledge of their osmolality may be an added parameter to consider when choosing therapeutic options for dry eye.

Related Results

OptimEYEzing Emergency Skills: A Novel Model for Ocular Procedural Education for Emergency Medicine Residents
OptimEYEzing Emergency Skills: A Novel Model for Ocular Procedural Education for Emergency Medicine Residents
Audience: This model for ocular procedural education is designed to instruct emergency medicine residents of all levels of training. Introduction: Ocular complaints are a common pr...
To Lube or not to Lube: The Effect of Intrapartum Lubricant use on Vaginal Microbiota
To Lube or not to Lube: The Effect of Intrapartum Lubricant use on Vaginal Microbiota
PurposeThis study aimed to characterize the composition of vaginal microbiota during labor and to investigate the effect of lubricant use on its bacterial composition.Research Ques...
Evaluation of Novel Surfactant Based Metal to Metal Friction Reducer
Evaluation of Novel Surfactant Based Metal to Metal Friction Reducer
Abstract Horizontal and deviated well architectures are now quite common as they facilitate drainage of reservoir in a cost-effective manner, such architectures intr...
Lubricants Health Monitoring
Lubricants Health Monitoring
Fault inception and growth in the components of a mechanical power drive are often heavily affected by the lubricant health. As a consequence, monitoring the l...
Experimental Study on the Impact of Lubricant on the Performance of Gravity-Assisted Separated Heat Pipe
Experimental Study on the Impact of Lubricant on the Performance of Gravity-Assisted Separated Heat Pipe
Gravity-assisted separation heat pipes (GSHPs) are extensively utilized in telecommunications base stations and data centers. To ensure year-round cooling, integrating GSHPs direct...
Nano Carrier-Mediated Ocular Therapeutic Delivery: A Comprehensive Review
Nano Carrier-Mediated Ocular Therapeutic Delivery: A Comprehensive Review
Abstract: Ocular diseases such as glaucoma, age-related macular degeneration (AMD), and diabetic retinopathy are leading causes of vision impairment and blindness globally. Despite...
A 5 year retrospective study on epidemiological pattern of ocular trauma
A 5 year retrospective study on epidemiological pattern of ocular trauma
Background: One of the delicate structure in the human body is eye and trauma to the eye is essentially a very grave matter. Major cause of preventable monocular blindness and visu...
Development and Optimization of Eudragit® L100 Film for Ocular Delivery of Prednisolone for Dry Eye
Development and Optimization of Eudragit® L100 Film for Ocular Delivery of Prednisolone for Dry Eye
Abstract Background: One of the more prevalent ocular conditions, dry eye causes between 30 to 40 million individuals in the United States on its own and is a serious human...

Back to Top