Javascript must be enabled to continue!
Early Age Performance of OPC-GGBFS-Concretes Containing Belite-CSA Cement Cured at Sub-Zero Temperatures
View through CrossRef
This study determined how replacing sodium nitrate-based antifreeze admixture (AF) with belite-calcium sulfoaluminate (belite-CSA) cement affects the early age properties of ecological concretes based on ordinary Portland cement (OPC) and ground granulated blast-furnace slag (GGBFS). Concrete specimens were cured at −15 °C and treated in various ways before testing, i.e., no treatment, stored at 20 °C for 12 and 24 h. Generally, the addition of belite-CSA cement shortened the setting time due to the rapid formation of ettringite. The incorporation of 25 wt% of antifreeze admixture (AF) to the OPC-GGBFS concrete cured at −15 °C partially inhibited ice formation and enabled the continuation of hydration processes. This trend was observed for all samples, independent of the applied AF after freezing curing. On the contrary, the addition of 20 wt% of CSA failed to inhibit the ice formation and increased the risk of frost damage for concretes despite the treatment after freezing. These concrete specimens had lower hydration, lower strength, and a more porous binder matrix. The microstructure of the binder matrix was significantly affected by the amount of CSA and extreme negative curing, followed by no notable recovery post-curing at room temperature. Therefore, pre-curing at room temperature for at least 6 h has the potential to avoid frost damage. Concrete containing 25 wt% AF combined with 12 h and 24 h of curing at 20 °C after removal from freezing and prior to testing could enhance the compressive strengths of all concretes. The renewed hydration was indicated as the main influencing factor.
Title: Early Age Performance of OPC-GGBFS-Concretes Containing Belite-CSA Cement Cured at Sub-Zero Temperatures
Description:
This study determined how replacing sodium nitrate-based antifreeze admixture (AF) with belite-calcium sulfoaluminate (belite-CSA) cement affects the early age properties of ecological concretes based on ordinary Portland cement (OPC) and ground granulated blast-furnace slag (GGBFS).
Concrete specimens were cured at −15 °C and treated in various ways before testing, i.
e.
, no treatment, stored at 20 °C for 12 and 24 h.
Generally, the addition of belite-CSA cement shortened the setting time due to the rapid formation of ettringite.
The incorporation of 25 wt% of antifreeze admixture (AF) to the OPC-GGBFS concrete cured at −15 °C partially inhibited ice formation and enabled the continuation of hydration processes.
This trend was observed for all samples, independent of the applied AF after freezing curing.
On the contrary, the addition of 20 wt% of CSA failed to inhibit the ice formation and increased the risk of frost damage for concretes despite the treatment after freezing.
These concrete specimens had lower hydration, lower strength, and a more porous binder matrix.
The microstructure of the binder matrix was significantly affected by the amount of CSA and extreme negative curing, followed by no notable recovery post-curing at room temperature.
Therefore, pre-curing at room temperature for at least 6 h has the potential to avoid frost damage.
Concrete containing 25 wt% AF combined with 12 h and 24 h of curing at 20 °C after removal from freezing and prior to testing could enhance the compressive strengths of all concretes.
The renewed hydration was indicated as the main influencing factor.
Related Results
Synthèse et stabilité de la bélite : étude du potentiel cimentier
Synthèse et stabilité de la bélite : étude du potentiel cimentier
La politique mondiale de réduction des émissions de gaz à effet serre repose en grande partie sur la recherche de nouvelles solutions pour l’industrie cimentaire qui contribue larg...
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
This study compares the strength of the native bone-cement bond and the old-new cement bond under cyclic loading, using third generation cementing technique, rasping and contaminat...
Volume Deformation and Hydration Behavior of Ordinary Portland Cement/Calcium Sulfoaluminate Cement Blends
Volume Deformation and Hydration Behavior of Ordinary Portland Cement/Calcium Sulfoaluminate Cement Blends
Blends of ordinary Portland cement (OPC) and calcium sulfoaluminate (CSA) cement can be used to adjust the properties of cement for specific applications. In this study, CSA cement...
Technical Evaluation of Portland-Limestone Cement as a Replacement for Ordinary Portland Cement
Technical Evaluation of Portland-Limestone Cement as a Replacement for Ordinary Portland Cement
Abstract
Portland -Limestone Cement (PLC) is becoming increasingly prevalent as a replacement for Ordinary Portland Cement (OPC) in many industries as a method to re...
Effects of perceptions on adoption of climate-smart agriculture innovations: empirical evidence from the upper Blue Nile Highlands of Ethiopia
Effects of perceptions on adoption of climate-smart agriculture innovations: empirical evidence from the upper Blue Nile Highlands of Ethiopia
Purpose
This study aims to examine smallholder farmers’ perceptions toward the adoption of climate-smart agriculture (CSA) in smallholder farmers in the Upper Blue Nile Highlands o...
Expanding Cements for Primary Cementing
Expanding Cements for Primary Cementing
Abstract
The expansion of cement and the effect of various expansive aids upon oil well cementing compositions have been investigated to determine the amount of e...
Behavior of Nano Calcium Carbonate Modified Smart Cement Contaminated with Oil Based Drilling Mud
Behavior of Nano Calcium Carbonate Modified Smart Cement Contaminated with Oil Based Drilling Mud
Abstract
As oil and gas exploration and production expands around the world, there are unique challenges in well construction beginning at the seafloor. There are se...
Real-Time Distributed Fiber Optic Sensing for Cement Sheath Integrity Monitoring
Real-Time Distributed Fiber Optic Sensing for Cement Sheath Integrity Monitoring
ABSTRACT:
The integrity of cement sheath is critical to oil and gas effective extraction, in which the cement displacement efficiency and solidify quality are the...

