Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Optical system design of the coded aperture imaging spectrometer

View through CrossRef
The coded aperture imaging spectrometer system based on the double-Amici-prism is designed in this paper, which includes the telescope objective, the coded template, the double-Amici-prism, the collimator lens and the imaging lens. This optical system can obtain a high diffraction efficiency. Compared to the imaging spectrometer system with a slit for this kind of system, the field of view is a two-dimensional spatial expansion, increasing the difficulty of design. For the subsequent data inversion algorithm, perfect imaging is needed, and based on this, the optical aberration of the system should be corrected carefully wildly. In this paper, we design and analyse the features of the imaging spectrometer system based on the double-Amici-prism, then the comple imaging spectrometer system. Telescope objective is designed to be telecentric, its MTF at 39 line pairs is 0.8, implying that good images can be obtained. Innovatively, an inverted telescope objective is used as a collimation system.The imaging spectrometer system's MTF at 39 line pairs is higher than 0.65. The imaging of the outdoor target scene, obtained by the coded aperture imaging spectrometer, proves that the design principle is feasible,the system is of high diffraction efficiency, the full-field imaging is of good quality, and the full spectrum of data is creditabe.
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Title: Optical system design of the coded aperture imaging spectrometer
Description:
The coded aperture imaging spectrometer system based on the double-Amici-prism is designed in this paper, which includes the telescope objective, the coded template, the double-Amici-prism, the collimator lens and the imaging lens.
This optical system can obtain a high diffraction efficiency.
Compared to the imaging spectrometer system with a slit for this kind of system, the field of view is a two-dimensional spatial expansion, increasing the difficulty of design.
For the subsequent data inversion algorithm, perfect imaging is needed, and based on this, the optical aberration of the system should be corrected carefully wildly.
In this paper, we design and analyse the features of the imaging spectrometer system based on the double-Amici-prism, then the comple imaging spectrometer system.
Telescope objective is designed to be telecentric, its MTF at 39 line pairs is 0.
8, implying that good images can be obtained.
Innovatively, an inverted telescope objective is used as a collimation system.
The imaging spectrometer system's MTF at 39 line pairs is higher than 0.
65.
The imaging of the outdoor target scene, obtained by the coded aperture imaging spectrometer, proves that the design principle is feasible,the system is of high diffraction efficiency, the full-field imaging is of good quality, and the full spectrum of data is creditabe.

Related Results

Analysis on the simplified optic coma effect on spectral image inversion of coded aperture spectral imager
Analysis on the simplified optic coma effect on spectral image inversion of coded aperture spectral imager
With the novel spectrum imaging technology development in recent years, the push-broom coded-aperture spectral imaging (PCASI) shows the advantages of high throughput, high SNR, hi...
Design
Design
Conventional definitions of design rarely capture its reach into our everyday lives. The Design Council, for example, estimates that more than 2.5 million people use design-related...
Design and Development of the VenSpec-H Instrument
Design and Development of the VenSpec-H Instrument
Introduction: VenSpec-H (Venus Spectrometer with High resolution), part of ESA’s EnVision M5 mission to Venus, is currently in Phase A (started in January 2019) ...
Modeling and evaluation of performance of dual field-of-view common-aperture dual-band imaging system
Modeling and evaluation of performance of dual field-of-view common-aperture dual-band imaging system
For the modeling and evaluation of dual field-of-view (FOV) common-aperture dual-band imaging system performance, two factors must be considered at the same time. One is that the s...
Full-field x-ray fluorescence imaging using a Fresnel zone plate coded aperture
Full-field x-ray fluorescence imaging using a Fresnel zone plate coded aperture
We present an approach to full-field x-ray fluorescence imaging that uses a Fresnel zone plate as a coded aperture positioned between the object and detector. For this particular c...
Development of electro‐optical PCBs with polymer waveguides for high‐speed intra‐system interconnects
Development of electro‐optical PCBs with polymer waveguides for high‐speed intra‐system interconnects
PurposeThe purpose of this paper is to study fabrication of optical‐PCBs on panel scale boards in a conventional modern PCB process environment. It evaluates impacts on board desig...
Design and Implementation of Matryoshka-type Neutron Spectrometer
Design and Implementation of Matryoshka-type Neutron Spectrometer
Abstract Aiming at portability and mobility, the design and implementation of a portable neutron spectrometer, namely the Matryoshka-type Neutron Spectrometer, was comple...
Influence of pixelation effect of image sensor on resolution of Fresnel incoherent correlation holography
Influence of pixelation effect of image sensor on resolution of Fresnel incoherent correlation holography
As a new technique of photomicrography of complex optical field, the Fresnel incoherent correlation holography (FINCH) is particularly attractive in recent years because of its inc...

Back to Top