Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Reduced exercise ventilatory efficiency in adults with cystic fibrosis and normal to moderately impaired lung function

View through CrossRef
Despite being a hallmark and an independent prognostic factor in several cardiopulmonary diseases, ventilatory efficiency—i.e., minute ventilation/carbon dioxide output relationship (V̇e/V̇co2)—has never been systematically explored in cystic fibrosis (CF). To provide a comprehensive frame of reference regarding measures of ventilatory efficiency in CF adults with normal to moderately impaired lung function and to confirm the hypothesis that V̇e/V̇co2is a sensitive marker of early lung disease. CF patients were divided into three groups, according to their spirometry: normal (G1), mild impairment (G2), and moderate impairment (G3) in lung function. All participants underwent incremental cardiopulmonary exercise testing on a cycle ergometer. Lowest V̇e/V̇co2ratio (nadir) and the slope and the intercept of the linear region of the V̇e/V̇co2relationship were contrasted in a two-center retrospective analysis, involving 72 CF patients and 36 healthy controls (HC). Compared with HC, CF patients had significantly higher V̇e/V̇co2nadir, slope, and intercept ( P < 0.001, P < 0.001, and P = 0.049, respectively). Subgroup analysis revealed significant differences in nadir ( P = 0.001) and slope ( P = 0.012) values even between HC and G1. Dynamic hyperinflation related negatively with slope ( P = 0.045) and positively with intercept ( P = 0.001), while no impact on nadir was observed. Ventilatory inefficiency is a clear feature of adults with CF, even among patients with normal spirometry. V̇e/V̇co2nadir seems to be the most reliable metric to describe ventilatory efficiency in CF adults. Further prospective studies are needed to clarify whether V̇e/V̇co2could represent a useful marker in the evaluation of early lung disease in CF.NEW & NOTEWORTHY This is the first study to investigate ventilatory efficiency in a cohort of adult cystic fibrosis (CF) patients with nonsevere lung disease. The finding of impaired ventilatory efficiency in patients with normal lung function confirms the higher sensitivity of exercise testing in detecting early lung disease compared with spirometry. Dynamic hyperinflation plays a significant role in determining the behavior of V̇e/V̇co2slope and intercept values with increasing lung function impairment. Apparently free from interference from mechanical constraints, V̇e/V̇co2nadir seems the most reliable parameter to evaluate ventilatory efficiency in CF adults.
Title: Reduced exercise ventilatory efficiency in adults with cystic fibrosis and normal to moderately impaired lung function
Description:
Despite being a hallmark and an independent prognostic factor in several cardiopulmonary diseases, ventilatory efficiency—i.
e.
, minute ventilation/carbon dioxide output relationship (V̇e/V̇co2)—has never been systematically explored in cystic fibrosis (CF).
To provide a comprehensive frame of reference regarding measures of ventilatory efficiency in CF adults with normal to moderately impaired lung function and to confirm the hypothesis that V̇e/V̇co2is a sensitive marker of early lung disease.
CF patients were divided into three groups, according to their spirometry: normal (G1), mild impairment (G2), and moderate impairment (G3) in lung function.
All participants underwent incremental cardiopulmonary exercise testing on a cycle ergometer.
Lowest V̇e/V̇co2ratio (nadir) and the slope and the intercept of the linear region of the V̇e/V̇co2relationship were contrasted in a two-center retrospective analysis, involving 72 CF patients and 36 healthy controls (HC).
Compared with HC, CF patients had significantly higher V̇e/V̇co2nadir, slope, and intercept ( P < 0.
001, P < 0.
001, and P = 0.
049, respectively).
Subgroup analysis revealed significant differences in nadir ( P = 0.
001) and slope ( P = 0.
012) values even between HC and G1.
Dynamic hyperinflation related negatively with slope ( P = 0.
045) and positively with intercept ( P = 0.
001), while no impact on nadir was observed.
Ventilatory inefficiency is a clear feature of adults with CF, even among patients with normal spirometry.
V̇e/V̇co2nadir seems to be the most reliable metric to describe ventilatory efficiency in CF adults.
Further prospective studies are needed to clarify whether V̇e/V̇co2could represent a useful marker in the evaluation of early lung disease in CF.
NEW & NOTEWORTHY This is the first study to investigate ventilatory efficiency in a cohort of adult cystic fibrosis (CF) patients with nonsevere lung disease.
The finding of impaired ventilatory efficiency in patients with normal lung function confirms the higher sensitivity of exercise testing in detecting early lung disease compared with spirometry.
Dynamic hyperinflation plays a significant role in determining the behavior of V̇e/V̇co2slope and intercept values with increasing lung function impairment.
Apparently free from interference from mechanical constraints, V̇e/V̇co2nadir seems the most reliable parameter to evaluate ventilatory efficiency in CF adults.

Related Results

Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
PO-180 Effect of Accumulated Exercise and Continuous Exercise on Energy Metabolism
PO-180 Effect of Accumulated Exercise and Continuous Exercise on Energy Metabolism
Objective   Sedentary behavior is the main feature of modern lifestyle, which relate to most chronic diseases. Therefore, it has great significance in both theory and practice of w...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Lists, Spatial Practice and Assistive Technologies for the Blind
Lists, Spatial Practice and Assistive Technologies for the Blind
IntroductionSupermarkets are functionally challenging environments for people with vision impairments. A supermarket is likely to house an average of 45,000 products in a median fl...
Understanding cystic lung lesions in smokers with interstitial lung disease: radiologic–pathological correlation
Understanding cystic lung lesions in smokers with interstitial lung disease: radiologic–pathological correlation
Abstract Due to destructive, fibrotic, and remodeling mechanisms, we can find a varied constellation of aerated and cystic lung lesions in smoker patients with intersti...
Sleep Habits and Occurrence of Lowback Pain among Craftsmen
Sleep Habits and Occurrence of Lowback Pain among Craftsmen
<span style="color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 10px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; ...

Back to Top