Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Absolute and non-invasive determination of the electron bunch length in a Free Electron Laser using a Bunch Compressor Monitor

View through CrossRef
Abstract In a linac driven Free Electron Laser (FEL), the shot-to-shot and non-invasive monitoring of the electron bunch length is normally ensured by Bunch Compressor Monitors (BCMs). The bunch-length dependent signal of a BCM results from the detection and integration - over a given frequency band - of the temporal coherent enhancement of the radiation spectral energy emitted by the electron beam while experiencing a longitudinal compression. In this work, we present a method that permits to express the relative variation of the bunch length as a function of the relative statistical fluctuations of the BCM and charge signals. Furthermore, in the case of a BCM equipped with two detectors simultaneously operating in two distinct wavelength bands, the method permits an absolute determination of the electron bunch length. The proposed method is beneficial to a FEL since it permits to tune the machine compression feedback with respect to the absolute measurement of the bunch length instead of a bunch-length dependent signal. In a CW-superconducting-linac driven FEL, it can offer the precious opportunity to implement a fully non-invasive and absolute diagnostics of the bunch length.
Research Square Platform LLC
Title: Absolute and non-invasive determination of the electron bunch length in a Free Electron Laser using a Bunch Compressor Monitor
Description:
Abstract In a linac driven Free Electron Laser (FEL), the shot-to-shot and non-invasive monitoring of the electron bunch length is normally ensured by Bunch Compressor Monitors (BCMs).
The bunch-length dependent signal of a BCM results from the detection and integration - over a given frequency band - of the temporal coherent enhancement of the radiation spectral energy emitted by the electron beam while experiencing a longitudinal compression.
In this work, we present a method that permits to express the relative variation of the bunch length as a function of the relative statistical fluctuations of the BCM and charge signals.
Furthermore, in the case of a BCM equipped with two detectors simultaneously operating in two distinct wavelength bands, the method permits an absolute determination of the electron bunch length.
The proposed method is beneficial to a FEL since it permits to tune the machine compression feedback with respect to the absolute measurement of the bunch length instead of a bunch-length dependent signal.
In a CW-superconducting-linac driven FEL, it can offer the precious opportunity to implement a fully non-invasive and absolute diagnostics of the bunch length.

Related Results

Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
In order to increase the accuracy of precise orbit determination for a single satellite or satellites in LEO formation, we propose using a LEO-to-GNSS laser interferometer, what we...
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Abstract A 2-section, 6-stage propylene recycle compressor experienced a catastrophic failure that resulted in extensive damage to its internals. The compressor was ...
Compressor Piping Design Effect on Vibration Data
Compressor Piping Design Effect on Vibration Data
One of the systems for oil and gas production supports is the nitrogen compression system. Problem found that condition of the compressor has high vibration with the maximum overal...
Centrifugal Compressor Design Considerations
Centrifugal Compressor Design Considerations
Initial design considerations of centrifugal compressor are commonly performed with experience base, although computer technology and numerical methods had made significantly progr...
Achieving the Three Dimensions of Mixed Refrigerant Compressor Efficiency
Achieving the Three Dimensions of Mixed Refrigerant Compressor Efficiency
Abstract Investors in small-scale LNG (SSLNG) face the grave challenge of achieving cost efficiency, operational efficiency, and energy efficiency in the equipment t...
The Effects of Wet Compression on Gas Turbine Engine Operating Performance
The Effects of Wet Compression on Gas Turbine Engine Operating Performance
Water, in the liquid or vapor phase, injected at various locations into the gas turbine cycle has frequently been employed to improve engine performance. One such way to improve en...
Approach to Model Thermistor Based AC Compressor Cut-OFF/Cut-IN Phenomenon in 1D Simulation of Mobile Air Conditioning
Approach to Model Thermistor Based AC Compressor Cut-OFF/Cut-IN Phenomenon in 1D Simulation of Mobile Air Conditioning
<div class="section abstract"><div class="htmlview paragraph">This paper documents the approach followed to simulate the physical phenomenon of thermistor based AC comp...

Back to Top