Javascript must be enabled to continue!
Absolute and non-invasive determination of the electron bunch length in a Free Electron Laser using a Bunch Compressor Monitor
View through CrossRef
Abstract
In a linac driven Free Electron Laser (FEL), the shot-to-shot and non-invasive monitoring of the electron bunch length is normally ensured by Bunch Compressor Monitors (BCMs). The bunch-length dependent signal of a BCM results from the detection and integration - over a given frequency band - of the temporal coherent enhancement of the radiation spectral energy emitted by the electron beam while experiencing a longitudinal compression. In this work, we present a method that permits to express the relative variation of the bunch length as a function of the relative statistical fluctuations of the BCM and charge signals. Furthermore, in the case of a BCM equipped with two detectors simultaneously operating in two distinct wavelength bands, the method permits an absolute determination of the electron bunch length. The proposed method is beneficial to a FEL since it permits to tune the machine compression feedback with respect to the absolute measurement of the bunch length instead of a bunch-length dependent signal. In a CW-superconducting-linac driven FEL, it can offer the precious opportunity to implement a fully non-invasive and absolute diagnostics of the bunch length.
Title: Absolute and non-invasive determination of the electron bunch length in a Free Electron Laser using a Bunch Compressor Monitor
Description:
Abstract
In a linac driven Free Electron Laser (FEL), the shot-to-shot and non-invasive monitoring of the electron bunch length is normally ensured by Bunch Compressor Monitors (BCMs).
The bunch-length dependent signal of a BCM results from the detection and integration - over a given frequency band - of the temporal coherent enhancement of the radiation spectral energy emitted by the electron beam while experiencing a longitudinal compression.
In this work, we present a method that permits to express the relative variation of the bunch length as a function of the relative statistical fluctuations of the BCM and charge signals.
Furthermore, in the case of a BCM equipped with two detectors simultaneously operating in two distinct wavelength bands, the method permits an absolute determination of the electron bunch length.
The proposed method is beneficial to a FEL since it permits to tune the machine compression feedback with respect to the absolute measurement of the bunch length instead of a bunch-length dependent signal.
In a CW-superconducting-linac driven FEL, it can offer the precious opportunity to implement a fully non-invasive and absolute diagnostics of the bunch length.
Related Results
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Abstract
A 2-section, 6-stage propylene recycle compressor experienced a catastrophic failure that resulted in extensive damage to its internals. The compressor was ...
Centrifugal Compressor Design Considerations
Centrifugal Compressor Design Considerations
Initial design considerations of centrifugal compressor are commonly performed with experience base, although computer technology and numerical methods had made significantly progr...
Achieving the Three Dimensions of Mixed Refrigerant Compressor Efficiency
Achieving the Three Dimensions of Mixed Refrigerant Compressor Efficiency
Abstract
Investors in small-scale LNG (SSLNG) face the grave challenge of achieving cost efficiency, operational efficiency, and energy efficiency in the equipment t...
The Effects of Wet Compression on Gas Turbine Engine Operating Performance
The Effects of Wet Compression on Gas Turbine Engine Operating Performance
Water, in the liquid or vapor phase, injected at various locations into the gas turbine cycle has frequently been employed to improve engine performance. One such way to improve en...
Approach to Model Thermistor Based AC Compressor Cut-OFF/Cut-IN Phenomenon in 1D Simulation of Mobile Air Conditioning
Approach to Model Thermistor Based AC Compressor Cut-OFF/Cut-IN Phenomenon in 1D Simulation of Mobile Air Conditioning
<div class="section abstract"><div class="htmlview paragraph">This paper documents the approach followed to simulate the physical phenomenon of thermistor based AC comp...
USE OF THE THEORY OF FINITE AUTOMATA FOR SUPERVISION OF THE OPERATION OF THE COMPRESSOR UNIT
USE OF THE THEORY OF FINITE AUTOMATA FOR SUPERVISION OF THE OPERATION OF THE COMPRESSOR UNIT
The purpose of the publication is to develop a methodology for presenting the unit "6 kV compressor-synchronous electric motor" in the form of a finite state machine.
It is hypoth...
Digital Compressor Analytics
Digital Compressor Analytics
Norwegian gas export is a high value business, where small and transient disturbances may cause substantial production losses. Process experience has shown that the compressor syst...
Multicriteria Optimization of Axial Low Pressure Compressor of Gas Turbine Power Plant
Multicriteria Optimization of Axial Low Pressure Compressor of Gas Turbine Power Plant
The paper shows a method of the gas-dynamic refining of three-stage axial compressor based on the joint usage of mathematical optimization software IOSO and CFD complex NUMECA. The...