Javascript must be enabled to continue!
Flexor Tendon Problems after Volar Plate Fixation of Distal Radius Fractures
View through CrossRef
Four cases of flexor tendon problems which developed after volar plate fixation of distal radius fractures are presented. All cases were associated with close contact of the screws or distal edge of the plate with the flexor tendons. Poor bone stock or multiple bone fragments allowing loosening of the plate or non-locking screws cause the hardware to irritate the flexor tendons and ultimately lead to rupture. The flexor tendons involved include the flexor carpi radialis, flexor pollicis longus and flexor digitorum superficialis, and flexor digitorum profundus to the index and long fingers.
Title: Flexor Tendon Problems after Volar Plate Fixation of Distal Radius Fractures
Description:
Four cases of flexor tendon problems which developed after volar plate fixation of distal radius fractures are presented.
All cases were associated with close contact of the screws or distal edge of the plate with the flexor tendons.
Poor bone stock or multiple bone fragments allowing loosening of the plate or non-locking screws cause the hardware to irritate the flexor tendons and ultimately lead to rupture.
The flexor tendons involved include the flexor carpi radialis, flexor pollicis longus and flexor digitorum superficialis, and flexor digitorum profundus to the index and long fingers.
Related Results
Flexor Pollicis Longus Tendon Rupture after Distal Radius Volar Plating and Reconstruction with Interpositional Palmaris Tendon Graft: A Case Report
Flexor Pollicis Longus Tendon Rupture after Distal Radius Volar Plating and Reconstruction with Interpositional Palmaris Tendon Graft: A Case Report
Introduction: Distal radius fractures constitute one of the most prevalent upper extremity orthopedic injuries, predominantly resulting from falls onto an outstretched hand with an...
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra...
SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
Background and Objective: The most common hand fractures among adult population are distal radius fractures and optimal management of these fractures remains controversial. Several...
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
Abstract
Objective: The aim of this study was to present a technique that allows the surgeon to easily and reliably achieve volar tilt in dorsally displaced distal radius fract...
Hospital Stay Duration and Postoperative Complications among Patients Undergoing Volar Buttress Plate for Fixation in Volar Barton’s Fracture of the Distal Radius
Hospital Stay Duration and Postoperative Complications among Patients Undergoing Volar Buttress Plate for Fixation in Volar Barton’s Fracture of the Distal Radius
Introduction: Volar Barton’s fractures of the distal radius are complex injuries requiring precise surgical intervention to ensure optimal functional outcomes and minimize complica...
Hospital Stay Duration and Postoperative Complications among Patients Undergoing Volar Buttress Plate for Fixation in Volar Barton’s Fracture of the Distal Radius
Hospital Stay Duration and Postoperative Complications among Patients Undergoing Volar Buttress Plate for Fixation in Volar Barton’s Fracture of the Distal Radius
Introduction: Volar Barton’s fractures of the distal radius are complex injuries requiring precise surgical intervention to ensure optimal functional outcomes and minimize complica...
Outcome of volar Barton fractures of distal radius managed with open reduction and internal fixation with volar locking plate
Outcome of volar Barton fractures of distal radius managed with open reduction and internal fixation with volar locking plate
Background: Volar Barton fractures of distal radius almost always require a surgical fixation. Near anatomical reduction and a stout fixation is imperative for good outcome. The pr...
The Use of a Tendon Protector Sheath for Prevention of First Extensor Compartment Tendon Adhesions after Radial Column Plating for Distal Radius Fracture: A Case Report
The Use of a Tendon Protector Sheath for Prevention of First Extensor Compartment Tendon Adhesions after Radial Column Plating for Distal Radius Fracture: A Case Report
Introduction: Although volar locking plates are the most commonly used implant method for open reduction and internal fixation (ORIF) of distal radius fractures, complex fractures ...