Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Estimating installed cooling capacities on city scale

View through CrossRef
Heating and cooling of buildings is one of the largest final energy uses and largest sources of greenhouse gas emissions. To reduce the impact of heating and cooling on our climate, more efficient strategies are needed. Coupling and centralizing the production of heat and cold in combination with underground seasonal thermal storage (UTES) can significantly reduce CO2 emissions and costs. To plan and implement such strategies for heating and cooling, information on sources and sinks of heat and cold is essential for local authorities. However, spatial information on the cooling sector is rare and difficult to obtain. Often, the theoretical cooling demand of specific buildings and building types is modeled, but not met by air-conditioning equipment in reality. On the other hand, large-scale cooling demand models, which focus on entire countries, may use data from different countries as proxy or are not applicable below kilometer-scale.In this study, we present a method to identify air-conditioning equipment on the rooftops of buildings and quantify their cooling capacity. Thus, air-cooled and hybrid evaporative condensers, cooling towers and packaged rooftop units are detected on aerial images. Using manufacturer data, regression analyses are created to estimate the cooling capacity based on the size of the units and the number of condenser fans. The unit locations and all required parameters are obtained by convolutional neural network-based pixel classification models, which are easily executable within a geographical information system (GIS) framework. The approach is successfully evaluated by testing the capability of the detection models and comparing our estimated cooling capacities to the actual installed cooling capacities of air-conditioners for different locations. The detection performance strongly depends on the resolution of the used aerial images. At a resolution of 8 cm/pixel, the model detects 93% of the units and the pixel classification overestimates the relevant parameters for the regression by 0.7%. Using the regression analyses, the overall capacity in the evaluated areas is overestimated by 7-21%. To demonstrate the capability of our approach, we map the cooling capacity of air-conditioners in parts of Manhattan. In the Manhattan financial district alone, a cooling capacity of over 2 GW is estimated, which is equivalent to 1.3% of the summer peak load demand of the energy grid of the entire state of New York.The presented approach is a fast and easy to conduct method that requires little input data. It can detect individual air conditioners over large areas. The obtained information can support the creation of cooling cadastres and can serve as supplement or validation for other cooling demand models, such as building stock models, or example to include additional building types, such as industrial buildings.
Title: Estimating installed cooling capacities on city scale
Description:
Heating and cooling of buildings is one of the largest final energy uses and largest sources of greenhouse gas emissions.
To reduce the impact of heating and cooling on our climate, more efficient strategies are needed.
Coupling and centralizing the production of heat and cold in combination with underground seasonal thermal storage (UTES) can significantly reduce CO2 emissions and costs.
To plan and implement such strategies for heating and cooling, information on sources and sinks of heat and cold is essential for local authorities.
However, spatial information on the cooling sector is rare and difficult to obtain.
Often, the theoretical cooling demand of specific buildings and building types is modeled, but not met by air-conditioning equipment in reality.
On the other hand, large-scale cooling demand models, which focus on entire countries, may use data from different countries as proxy or are not applicable below kilometer-scale.
In this study, we present a method to identify air-conditioning equipment on the rooftops of buildings and quantify their cooling capacity.
Thus, air-cooled and hybrid evaporative condensers, cooling towers and packaged rooftop units are detected on aerial images.
Using manufacturer data, regression analyses are created to estimate the cooling capacity based on the size of the units and the number of condenser fans.
The unit locations and all required parameters are obtained by convolutional neural network-based pixel classification models, which are easily executable within a geographical information system (GIS) framework.
The approach is successfully evaluated by testing the capability of the detection models and comparing our estimated cooling capacities to the actual installed cooling capacities of air-conditioners for different locations.
The detection performance strongly depends on the resolution of the used aerial images.
At a resolution of 8 cm/pixel, the model detects 93% of the units and the pixel classification overestimates the relevant parameters for the regression by 0.
7%.
Using the regression analyses, the overall capacity in the evaluated areas is overestimated by 7-21%.
To demonstrate the capability of our approach, we map the cooling capacity of air-conditioners in parts of Manhattan.
In the Manhattan financial district alone, a cooling capacity of over 2 GW is estimated, which is equivalent to 1.
3% of the summer peak load demand of the energy grid of the entire state of New York.
The presented approach is a fast and easy to conduct method that requires little input data.
It can detect individual air conditioners over large areas.
The obtained information can support the creation of cooling cadastres and can serve as supplement or validation for other cooling demand models, such as building stock models, or example to include additional building types, such as industrial buildings.

Related Results

Estimating cooling capacities from aerial images using convolutional neural networks
Estimating cooling capacities from aerial images using convolutional neural networks
In recent decades, the global cooling demand has significantly increased and is expected to grow even further in the future. However, knowledge regarding the spatial distribution o...
Experimental Feasibility Study of Radial Injection Cooling of Three-Pad Air Foil Bearings
Experimental Feasibility Study of Radial Injection Cooling of Three-Pad Air Foil Bearings
The foil bearing (FB) is one type of hydrodynamic bearing using air or another gas as a lubricant. When FBs are designed, installed, and operated properly, they are a very cost-eff...
Enhancement of Film Cooling Effectiveness Using Dean Vortices
Enhancement of Film Cooling Effectiveness Using Dean Vortices
Abstract Film cooling technology is widely used in gas turbines. Improvement of gas turbine thermal efficiency, specific power and specific thrust can be achieved by...
Impingement/Effusion Cooling With Low Coolant Mass Flow
Impingement/Effusion Cooling With Low Coolant Mass Flow
A low coolant mass flow impingement/effusion design for a low NOx combustor wall cooling application was predicted, using conjugate heat transfer (CHT) computational fluid dynamics...
Large Eddy Simulations on Fan Shaped Film Cooling Hole With Various Inlet Turbulence Generation Methods
Large Eddy Simulations on Fan Shaped Film Cooling Hole With Various Inlet Turbulence Generation Methods
Abstract Large eddy simulations on well-known 7-7-7 fan shaped cooling hole have been carried out. Film cooling methods are generally applied to high pressure turbin...
Combustor Effusion Cooling Multiparameter Aerothermal Numerical Analysis
Combustor Effusion Cooling Multiparameter Aerothermal Numerical Analysis
The solid temperature prediction is one of the most widespread type of modelization used in the industry. One reading this study might wonder why there would be readymade solutions...
Anomalous Magnetorheological Response for Carrageenan Magnetic Hydrogels Prepared by Natural Cooling
Anomalous Magnetorheological Response for Carrageenan Magnetic Hydrogels Prepared by Natural Cooling
The effect of cooling rate on the magnetorheological response was investigated for magnetic hydrogels consisting of carrageenan and carbonyl iron particles with a concentration of ...
Anomalous Magnetorheological Response for Carrageenan Magnetic Hydrogels Prepared by Natural Cooling
Anomalous Magnetorheological Response for Carrageenan Magnetic Hydrogels Prepared by Natural Cooling
The effect of the cooling rate on magnetorheological response was investigated for magnetic hydrogels consisting of carrageenan and carbonyl iron particles with a concentration of ...

Back to Top