Javascript must be enabled to continue!
A chemical model of meteoric ablation
View through CrossRef
Abstract. Most of the extraterrestrial dust entering the Earth's atmosphere ablates to produce metal vapours, which have significant effects on the aeronomy of the upper mesosphere and lower thermosphere. A new Chemical Ablation Model (CAMOD) is described which treats the physics and chemistry of ablation, by including the following processes: sputtering by inelastic collisions with air molecules before the meteoroid melts; evaporation of atoms and oxides from the molten particle; diffusion-controlled migration of the volatile constituents (Na and K) through the molten particle; and impact ionization of the ablated fragments by hyperthermal collisions with air molecules. Evaporation is based on thermodynamic equilibrium in the molten meteoroid (treated as a melt of metal oxides), and between the particle and surrounding vapour phase. The loss rate of each element is then determined assuming Langmuir evaporation. CAMOD successfully predicts the meteor head echo appearance heights, observed from incoherent scatter radars, over a wide range of meteoroid velocities. The model also confirms that differential ablation explains common-volume lidar observations of K, Ca and Ca+ in fresh meteor trails. CAMOD is then used to calculate the injection rates into the atmosphere of a variety of elements as a function of altitude, integrated over the meteoroid mass and velocity distributions. The most abundant elements (Fe, Mg and Si) have peak injection rates around 85 km, with Na and K about 8 km higher. The more refractory element Ca ablates around 82 km with a Na:Ca ratio of 4:1, which does therefore not explain the depletion of atomic Ca to Na, by more than 2 orders of magnitude, in the upper mesosphere. Diffusion of the most volatile elements (Na and K) does not appear to be rate-limiting except in the fastest meteoroids. Non-thermal sputtering causes ~35% mass loss from the fastest (~60–70 km s−1) and smallest (10−17–10−13g) meteoroids, but makes a minor contribution to the overall ablation rate.
Title: A chemical model of meteoric ablation
Description:
Abstract.
Most of the extraterrestrial dust entering the Earth's atmosphere ablates to produce metal vapours, which have significant effects on the aeronomy of the upper mesosphere and lower thermosphere.
A new Chemical Ablation Model (CAMOD) is described which treats the physics and chemistry of ablation, by including the following processes: sputtering by inelastic collisions with air molecules before the meteoroid melts; evaporation of atoms and oxides from the molten particle; diffusion-controlled migration of the volatile constituents (Na and K) through the molten particle; and impact ionization of the ablated fragments by hyperthermal collisions with air molecules.
Evaporation is based on thermodynamic equilibrium in the molten meteoroid (treated as a melt of metal oxides), and between the particle and surrounding vapour phase.
The loss rate of each element is then determined assuming Langmuir evaporation.
CAMOD successfully predicts the meteor head echo appearance heights, observed from incoherent scatter radars, over a wide range of meteoroid velocities.
The model also confirms that differential ablation explains common-volume lidar observations of K, Ca and Ca+ in fresh meteor trails.
CAMOD is then used to calculate the injection rates into the atmosphere of a variety of elements as a function of altitude, integrated over the meteoroid mass and velocity distributions.
The most abundant elements (Fe, Mg and Si) have peak injection rates around 85 km, with Na and K about 8 km higher.
The more refractory element Ca ablates around 82 km with a Na:Ca ratio of 4:1, which does therefore not explain the depletion of atomic Ca to Na, by more than 2 orders of magnitude, in the upper mesosphere.
Diffusion of the most volatile elements (Na and K) does not appear to be rate-limiting except in the fastest meteoroids.
Non-thermal sputtering causes ~35% mass loss from the fastest (~60–70 km s−1) and smallest (10−17–10−13g) meteoroids, but makes a minor contribution to the overall ablation rate.
Related Results
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract
Introduction
Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
Ablation Performance of C/SiC-ZrC Composites
Ablation Performance of C/SiC-ZrC Composites
Abstract
To reveal the ablation performance of C/SiC-ZrC composites under different ablation methods, C/SiC-ZrC composites were prepared by chemical vapor deposition and pr...
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
Introduction: Novel ablation catheters equipped with
mini-electrodes (ME) offer high resolution mapping for target tissue.
This study aimed to evaluate the mapping performance and ...
Steam ablation needles based on porous radiation clusters
Steam ablation needles based on porous radiation clusters
Steam thermal ablation (STA) is an emerging minimally invasive treatment technique that utilizes the energy of high-temperature steam to treat diseased tissues. Compared to traditi...
Theoretical and experimental investigation of femtosecond laser processing fused silica
Theoretical and experimental investigation of femtosecond laser processing fused silica
By tracking the spatiotemporal distribution of the free electron density/temperature and laser intensity, the ablation threshold, depth and crater shape of fused silica for femtose...
Ablation index-guided ablation with milder targets for atrial fibrillation: Comparison between high power and low power ablation
Ablation index-guided ablation with milder targets for atrial fibrillation: Comparison between high power and low power ablation
BackgroundHigh power-ablation index (HP-AI)-guided ablation for atrial fibrillation (AF) targeting high AIs has been implemented in European countries. However, milder AI targets a...
Recent Advances in Catheter Ablation for Atrial Fibrillation and Non-pharmacological Stroke Prevention
Recent Advances in Catheter Ablation for Atrial Fibrillation and Non-pharmacological Stroke Prevention
Atrial Fibrillation is a common arrhythmia affecting 6 million people in the United States and 33 million people worldwide, associated with significant morbidity. Whereas restorati...
The anatomy investigation of cavotricuspid isthmus linear ablation navigated by CARTO
The anatomy investigation of cavotricuspid isthmus linear ablation navigated by CARTO
Objective
We sought to investigate the anatomy characteristics of cavotricuspid isthmus (CTI) and its influence on linear ablation navigated by CARTO in patients ...

