Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Optimization of contrast and dose in x-ray phase-contrast tomography with a Talbot-Lau interferometer

View through CrossRef
Abstract X-ray phase-contrast imaging has become a valuable tool for biomedical research due to its improved contrast abilities over regular attenuation-based imaging. The recently emerged Talbot-Lau interferometer can provide quantitative attenuation, phase-contrast and dark-field image data, even with low-brilliance x-ray tube sources. Thus, it has become a valid option for clinical environments. In this study, we analyze the effects of x-ray tube voltage and total number of images on the contrast-to-noise ratio (CNR) and dose-weighted CNR (CNRD) calculated from tomographic transmission and phase-contrast data of a phantom sample. Constant counting statistics regardless of the voltage was ensured by adjusting the image exposure time for each voltage setting. The results indicate that the x-ray tube voltage has a clear effect on both image contrast and noise. This effect is amplified in the case of phase-contrast images, which is explained by the polychromatic x-ray spectrum and the dependence of interferometer visibility on the spectrum. CNRD is additionally affected by the total imaging time. While submerging the sample into a water container effectively reduces image artefacts and improves the CNR, the additional attenuation of the water must be compensated with a longer exposure time. This reduces dose efficiency. Both the CNR and CNRD are higher in the phase-contrast images compared to transmission images. For transmission images, and phase-contrast images without the water container, CNRD can be increased by using higher tube voltages (in combination with a lower exposure time). For phase-contrast images with the water container, CNRD is increased with lower tube voltages. In general, the CNRD does not strongly depend on the number of tomographic angles or phase steps used.
Title: Optimization of contrast and dose in x-ray phase-contrast tomography with a Talbot-Lau interferometer
Description:
Abstract X-ray phase-contrast imaging has become a valuable tool for biomedical research due to its improved contrast abilities over regular attenuation-based imaging.
The recently emerged Talbot-Lau interferometer can provide quantitative attenuation, phase-contrast and dark-field image data, even with low-brilliance x-ray tube sources.
Thus, it has become a valid option for clinical environments.
In this study, we analyze the effects of x-ray tube voltage and total number of images on the contrast-to-noise ratio (CNR) and dose-weighted CNR (CNRD) calculated from tomographic transmission and phase-contrast data of a phantom sample.
Constant counting statistics regardless of the voltage was ensured by adjusting the image exposure time for each voltage setting.
The results indicate that the x-ray tube voltage has a clear effect on both image contrast and noise.
This effect is amplified in the case of phase-contrast images, which is explained by the polychromatic x-ray spectrum and the dependence of interferometer visibility on the spectrum.
CNRD is additionally affected by the total imaging time.
While submerging the sample into a water container effectively reduces image artefacts and improves the CNR, the additional attenuation of the water must be compensated with a longer exposure time.
This reduces dose efficiency.
Both the CNR and CNRD are higher in the phase-contrast images compared to transmission images.
For transmission images, and phase-contrast images without the water container, CNRD can be increased by using higher tube voltages (in combination with a lower exposure time).
For phase-contrast images with the water container, CNRD is increased with lower tube voltages.
In general, the CNRD does not strongly depend on the number of tomographic angles or phase steps used.

Related Results

Implementasi Rancangan Pendeteksi Gempa Bumi Menggunakan Android Dan Arduino
Implementasi Rancangan Pendeteksi Gempa Bumi Menggunakan Android Dan Arduino
Desa Lau Gumba merupakan Desa yang terletak di Kecamatan Brastagi Kabupaten Karo Provinsi Sumatera Utara yang cukup di kenal karena memiliki objek wisata yang cukup menarik untuk d...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Temporal Talbot effect: from a quasi-linear Talbot carpet to soliton crystals and Talbot solitons
Temporal Talbot effect: from a quasi-linear Talbot carpet to soliton crystals and Talbot solitons
The temporal Talbot effect refers to the periodic self-imaging of pulse trains in optical fibers. The connection between the linear and nonlinear temporal Talbot effect is still no...
A phase processor used in terahertz interferometer for tokamak
A phase processor used in terahertz interferometer for tokamak
Abstract The commonly used phase processing techniques include coherence method, zero-crossing comparison method and FFT method. Due to the influence of noise, ampli...
Realization of a nonlinear interferometer with parametric amplifiers
Realization of a nonlinear interferometer with parametric amplifiers
We construct an interferometer with parametric amplifiers as beam splitters. Because of the gain in the parametric amplifiers, the maximum output intensity of the interferometer ca...
Optimizing Hydroxyurea Dosing in Sickle Cell Anemia: The Uganda MTD Study
Optimizing Hydroxyurea Dosing in Sickle Cell Anemia: The Uganda MTD Study
Introduction. Hydroxyurea treatment has proven safety, feasibility, and efficacy for children with sickle cell anemia living in sub-Saharan Africa. Even in malaria endemic regions,...

Back to Top