Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A New Application of Sohrabi Albedo Neutron Dosimeters around a Plasma Focus Device

View through CrossRef
Abstract A new application of the Sohrabi albedo neutron dosimeters is reported for the first time for determination of very low-level neutron ambient dose equivalents on and around a 3.5 kJ plasma focus device (PFD). The Sohrabi dosimeters basically use a polycarbonate track detector as bare and/or in contact with 10B convertor(s) under special cadmium cover arrangements. Its sensitivity was improved by using enriched 10B under new cadmium arrangements in order to detect epithermal neutrons in addition to fast and thermal neutrons. Results of 12 dosimeters installed externally around the PFD at different azimuthal (φ) and polar (θ) angles showed that azimuthal (φ) fast, epithermal, thermal, and total neutron ambient dose equivalents were symmetric and isotropic, respectively, with values 55.15 ± 8.36, 1.36 ± 02, 0.53 ± 03, and 57.04 ± 8.62 μSv/shot at ~25 cm from anode top. Polar (θ) neutron ambient dose equivalent values on z-axis relative to 90o angle were relatively higher. Results of 38 dosimeters placed on PFD facility walls for workplace monitoring and on a BOMAB phantom at operator’s location for personal dose equivalent determination showed values below minimum detection limits after exposure to 130 PFD shots. However, an operator’s personal dose equivalents at ~1.0 and ~3.0 m from the anode top were estimated to be, respectively, ~13.7 and ~1.52 mSv y−1 using azimuthal angle (φ) values if the PFD operates, for example, up to 20 shots per day for 200 d y−1. Even under such an extreme assumption, annual personal dose equivalent is still much below 20 mSv, the annual ICRP dose limit for workers.
Ovid Technologies (Wolters Kluwer Health)
Title: A New Application of Sohrabi Albedo Neutron Dosimeters around a Plasma Focus Device
Description:
Abstract A new application of the Sohrabi albedo neutron dosimeters is reported for the first time for determination of very low-level neutron ambient dose equivalents on and around a 3.
5 kJ plasma focus device (PFD).
The Sohrabi dosimeters basically use a polycarbonate track detector as bare and/or in contact with 10B convertor(s) under special cadmium cover arrangements.
Its sensitivity was improved by using enriched 10B under new cadmium arrangements in order to detect epithermal neutrons in addition to fast and thermal neutrons.
Results of 12 dosimeters installed externally around the PFD at different azimuthal (φ) and polar (θ) angles showed that azimuthal (φ) fast, epithermal, thermal, and total neutron ambient dose equivalents were symmetric and isotropic, respectively, with values 55.
15 ± 8.
36, 1.
36 ± 02, 0.
53 ± 03, and 57.
04 ± 8.
62 μSv/shot at ~25 cm from anode top.
Polar (θ) neutron ambient dose equivalent values on z-axis relative to 90o angle were relatively higher.
Results of 38 dosimeters placed on PFD facility walls for workplace monitoring and on a BOMAB phantom at operator’s location for personal dose equivalent determination showed values below minimum detection limits after exposure to 130 PFD shots.
However, an operator’s personal dose equivalents at ~1.
0 and ~3.
0 m from the anode top were estimated to be, respectively, ~13.
7 and ~1.
52 mSv y−1 using azimuthal angle (φ) values if the PFD operates, for example, up to 20 shots per day for 200 d y−1.
Even under such an extreme assumption, annual personal dose equivalent is still much below 20 mSv, the annual ICRP dose limit for workers.

Related Results

Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
Assimilation of Satellite Albedo to Improve Simulations of Glacier Hydrology
Assimilation of Satellite Albedo to Improve Simulations of Glacier Hydrology
Wildfires and heatwaves have recently affected the hydrological system in unprecedented ways due to climate change. In cold regions, these extremes cause rapid reductions in snow a...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
Update of the radiation environment measurement results aboard ExoMars TGO in May 2018-June 202
Update of the radiation environment measurement results aboard ExoMars TGO in May 2018-June 202
AbstractThe dosimetric telescope Liulin-MO [1] for measuring the radiation environment onboard the ExoMars TGO is a module of the Fine Resolution Epithermal Neutron Detector (FREND...
The Estimation of Surface Albedo from DSCOVR EPIC
The Estimation of Surface Albedo from DSCOVR EPIC
Surface albedo is an important parameter in climate models. The main way to obtain continuous surface albedo for large areas is satellite remote sensing. However, the existing albe...
Ice surfaces of mountain glaciers : importance of liquid water and albedo variability
Ice surfaces of mountain glaciers : importance of liquid water and albedo variability
Importance de l’eau liquide et variabilité de l’albédo sur les surfaces en glace des glaciers de montagne Le changement climatique accélère la fonte de la neige et ...

Back to Top