Javascript must be enabled to continue!
A New Application of Sohrabi Albedo Neutron Dosimeters around a Plasma Focus Device
View through CrossRef
Abstract
A new application of the Sohrabi albedo neutron dosimeters is reported for the first time for determination of very low-level neutron ambient dose equivalents on and around a 3.5 kJ plasma focus device (PFD). The Sohrabi dosimeters basically use a polycarbonate track detector as bare and/or in contact with 10B convertor(s) under special cadmium cover arrangements. Its sensitivity was improved by using enriched 10B under new cadmium arrangements in order to detect epithermal neutrons in addition to fast and thermal neutrons. Results of 12 dosimeters installed externally around the PFD at different azimuthal (φ) and polar (θ) angles showed that azimuthal (φ) fast, epithermal, thermal, and total neutron ambient dose equivalents were symmetric and isotropic, respectively, with values 55.15 ± 8.36, 1.36 ± 02, 0.53 ± 03, and 57.04 ± 8.62 μSv/shot at ~25 cm from anode top. Polar (θ) neutron ambient dose equivalent values on z-axis relative to 90o angle were relatively higher. Results of 38 dosimeters placed on PFD facility walls for workplace monitoring and on a BOMAB phantom at operator’s location for personal dose equivalent determination showed values below minimum detection limits after exposure to 130 PFD shots. However, an operator’s personal dose equivalents at ~1.0 and ~3.0 m from the anode top were estimated to be, respectively, ~13.7 and ~1.52 mSv y−1 using azimuthal angle (φ) values if the PFD operates, for example, up to 20 shots per day for 200 d y−1. Even under such an extreme assumption, annual personal dose equivalent is still much below 20 mSv, the annual ICRP dose limit for workers.
Title: A New Application of Sohrabi Albedo Neutron Dosimeters around a Plasma Focus Device
Description:
Abstract
A new application of the Sohrabi albedo neutron dosimeters is reported for the first time for determination of very low-level neutron ambient dose equivalents on and around a 3.
5 kJ plasma focus device (PFD).
The Sohrabi dosimeters basically use a polycarbonate track detector as bare and/or in contact with 10B convertor(s) under special cadmium cover arrangements.
Its sensitivity was improved by using enriched 10B under new cadmium arrangements in order to detect epithermal neutrons in addition to fast and thermal neutrons.
Results of 12 dosimeters installed externally around the PFD at different azimuthal (φ) and polar (θ) angles showed that azimuthal (φ) fast, epithermal, thermal, and total neutron ambient dose equivalents were symmetric and isotropic, respectively, with values 55.
15 ± 8.
36, 1.
36 ± 02, 0.
53 ± 03, and 57.
04 ± 8.
62 μSv/shot at ~25 cm from anode top.
Polar (θ) neutron ambient dose equivalent values on z-axis relative to 90o angle were relatively higher.
Results of 38 dosimeters placed on PFD facility walls for workplace monitoring and on a BOMAB phantom at operator’s location for personal dose equivalent determination showed values below minimum detection limits after exposure to 130 PFD shots.
However, an operator’s personal dose equivalents at ~1.
0 and ~3.
0 m from the anode top were estimated to be, respectively, ~13.
7 and ~1.
52 mSv y−1 using azimuthal angle (φ) values if the PFD operates, for example, up to 20 shots per day for 200 d y−1.
Even under such an extreme assumption, annual personal dose equivalent is still much below 20 mSv, the annual ICRP dose limit for workers.
Related Results
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Abstract
Introduction
Cancer is one of the major medical problems threatening human health. Breast cancer ...
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract
The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
Assimilation of Satellite Albedo to Improve Simulations of Glacier Hydrology
Assimilation of Satellite Albedo to Improve Simulations of Glacier Hydrology
Wildfires and heatwaves have recently affected the hydrological system
in unprecedented ways due to climate change. In cold regions, these
extremes cause rapid reductions in snow a...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
A Novel Gamma-Thermal Neutron Evaluating Gas Saturation Method Using Pulsed Neutron Logging Tool With Dual-CLYC
In our previous research which has published in 62th SPWLA symposium, a numerical simulation method was proposed which about the double particle detector CLYC (Cs2LiYCl6:CE) to get...