Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A High-Sensitivity, Low-Drift MEMS Relative Gravimeter for Multi-Pixel Imaging Applications

View through CrossRef
<p><strong>Novelty / Progress Claim(s)</strong></p><p>This paper reports a capacitive readout-based MEMS relative gravimeter which can detect sub-Hz microseismic and slowly varying gravitational Earth tide signals. The gravimeter has a noise floor of 6-7 uGal/rt(Hz) at 1Hz and a linear drift of <250 uGal/day, metrics which are on a par with the commercially available gravimeters, and are leading in the field of MEMS accelerometers. The gravimeter is packaged in a standard ceramic-carrier and interfaced to a low-power, advanced FPGA-based readout. This setup is housed within a bespoke thermal enclosure, making the platform ideal for multi-pixel array-based implementation in the field.</p><p><strong>Background/State-of-the-Art</strong></p><p>Gravimeters are used to measure the local acceleration due to gravity (g). One of the emerging applications of gravimetry is in volcanology where gravimeters can be used to understand magma plumbing, providing information on volcanic activity/unrest events. However, this requires multi-pixel ‘gravity-imaging’ around volcanoes, a feat which is not possible using the expensive, complex, and large form-factor commercially available gravimeters.</p><p>Recently, researchers have developed MEMS-scale accelerometers which have excellent sensitivities but not yet demonstrated good long-term stability, making them non-viable for long-term monitoring of slow gravity changes (such as produced by magma flow). In a previous work, the authors have demonstrated an optical shadow-sensor readout based MEMS gravimeter with a sensitivity of 40 uGal/rt(Hz). Building on the work, a portable version of the gravimeter was also reported previously. The devices in both the setups were limited by the displacement noise of the optical shadow-sensor and the packageability of the setup.</p><p>In this paper, we are reporting a novel gravimeter which uses a capacitive-readout for sensing the proof-mass displacement, is embedded in a MEMS IC package, and uses advanced FPGA-based electronics for signal conditioning. The improved displacement sensitivity of the capacitive readout allows designing stiffer suspension-springs making the device more robust for operations in extreme environments. The acceleration sensitivity achieved using the new gravimeter is around 6-7 uGal/rt(Hz) at 1Hz, which is a significant improvement over the previous versions of the gravimeter. The device is currently being readied for field trials in the sectors of volcano gravimetry and oil & gas, showing the maturity of the technology.</p><p><strong>Methodology</strong></p><p>The reported gravimeter has a microfabricated silicon proof-mass which is suspended from thin flexures. Metal-combs are patterned on top of the proof-mass and a fixed glass layer with complementary combs is assembled to be at a close separation from the proof-mass. The overlapping combs act as a capacitor, the magnitude of which is dependent on the proof-mass displacement. The multi-layered gravimeter is embedded within a standard 32-pin ceramic DIP chip-carrier and wire bonded. The MEMS package is interfaced with analog signal conditioning electronics and a digital lock-in implementation is employed for converting the capacitance change into useful units (uGals).The electronics noise of the setup is measured to be <1 uGal. To reduce temperature-related effects, a mK active temperature control is implemented around the device. The packaged device is housed within a prototype thermal enclosure making the platform field-portable.</p>
Title: A High-Sensitivity, Low-Drift MEMS Relative Gravimeter for Multi-Pixel Imaging Applications
Description:
<p><strong>Novelty / Progress Claim(s)</strong></p><p>This paper reports a capacitive readout-based MEMS relative gravimeter which can detect sub-Hz microseismic and slowly varying gravitational Earth tide signals.
The gravimeter has a noise floor of 6-7 uGal/rt(Hz) at 1Hz and a linear drift of <250 uGal/day, metrics which are on a par with the commercially available gravimeters, and are leading in the field of MEMS accelerometers.
The gravimeter is packaged in a standard ceramic-carrier and interfaced to a low-power, advanced FPGA-based readout.
This setup is housed within a bespoke thermal enclosure, making the platform ideal for multi-pixel array-based implementation in the field.
</p><p><strong>Background/State-of-the-Art</strong></p><p>Gravimeters are used to measure the local acceleration due to gravity (g).
One of the emerging applications of gravimetry is in volcanology where gravimeters can be used to understand magma plumbing, providing information on volcanic activity/unrest events.
However, this requires multi-pixel ‘gravity-imaging’ around volcanoes, a feat which is not possible using the expensive, complex, and large form-factor commercially available gravimeters.
</p><p>Recently, researchers have developed MEMS-scale accelerometers which have excellent sensitivities but not yet demonstrated good long-term stability, making them non-viable for long-term monitoring of slow gravity changes (such as produced by magma flow).
In a previous work, the authors have demonstrated an optical shadow-sensor readout based MEMS gravimeter with a sensitivity of 40 uGal/rt(Hz).
Building on the work, a portable version of the gravimeter was also reported previously.
The devices in both the setups were limited by the displacement noise of the optical shadow-sensor and the packageability of the setup.
</p><p>In this paper, we are reporting a novel gravimeter which uses a capacitive-readout for sensing the proof-mass displacement, is embedded in a MEMS IC package, and uses advanced FPGA-based electronics for signal conditioning.
The improved displacement sensitivity of the capacitive readout allows designing stiffer suspension-springs making the device more robust for operations in extreme environments.
The acceleration sensitivity achieved using the new gravimeter is around 6-7 uGal/rt(Hz) at 1Hz, which is a significant improvement over the previous versions of the gravimeter.
The device is currently being readied for field trials in the sectors of volcano gravimetry and oil & gas, showing the maturity of the technology.
</p><p><strong>Methodology</strong></p><p>The reported gravimeter has a microfabricated silicon proof-mass which is suspended from thin flexures.
Metal-combs are patterned on top of the proof-mass and a fixed glass layer with complementary combs is assembled to be at a close separation from the proof-mass.
The overlapping combs act as a capacitor, the magnitude of which is dependent on the proof-mass displacement.
The multi-layered gravimeter is embedded within a standard 32-pin ceramic DIP chip-carrier and wire bonded.
The MEMS package is interfaced with analog signal conditioning electronics and a digital lock-in implementation is employed for converting the capacitance change into useful units (uGals).
The electronics noise of the setup is measured to be <1 uGal.
To reduce temperature-related effects, a mK active temperature control is implemented around the device.
The packaged device is housed within a prototype thermal enclosure making the platform field-portable.
</p>.

Related Results

Development and Assembly of a MEMS Based High-Sensitivity Relative Gravimeter for Multi-Pixel Imaging Applications 
Development and Assembly of a MEMS Based High-Sensitivity Relative Gravimeter for Multi-Pixel Imaging Applications 
<p>The manufacture and production of a high-sensitivity cost-effective gravimeter has the potential to change the methodology&a...
(Invited) A 1-mG MEMS Sensor
(Invited) A 1-mG MEMS Sensor
MEMS (microelectromechanical systems) technology has contributed substantially to the miniaturization of inertial sensors, such as accelerometers and gyroscopes [1]. Nowadays, MEMS...
RELIABILITY OF MEMS ACCELEROMETERS FOR INSTRUMENTAL INTENSITY MAPPING OF EARTHQUAKES
RELIABILITY OF MEMS ACCELEROMETERS FOR INSTRUMENTAL INTENSITY MAPPING OF EARTHQUAKES
This work investigates suitability of low cost Micro-Electro Mechanical System (MEMS) sensors in strong motion related studies, particularly in shaking intensity networks. Two type...
Single-Pixel MEMS Imaging Systems
Single-Pixel MEMS Imaging Systems
Single-pixel imaging technology is an attractive technology considering the increasing demand of imagers that can operate in wavelengths where traditional cameras have limited effi...
A MEMS IMU De-Noising Method Using Long Short Term Memory Recurrent Neural Networks (LSTM-RNN)
A MEMS IMU De-Noising Method Using Long Short Term Memory Recurrent Neural Networks (LSTM-RNN)
Microelectromechanical Systems (MEMS) Inertial Measurement Unit (IMU) containing a three-orthogonal gyroscope and three-orthogonal accelerometer has been widely utilized in positio...
A new sea ice state dependent parameterization for the free drift of sea ice
A new sea ice state dependent parameterization for the free drift of sea ice
Abstract. Free drift estimates of sea ice motion are necessary to produce a seamless observational record combining buoy and satellite-derived sea ice motion vectors. We develop a ...
Development of a MEMs gravimeter for drone-based field surveys.
Development of a MEMs gravimeter for drone-based field surveys.
<p>Gravimetry allows us to study sub-surface structures remotely by measuring changes in Earth's surface gravitational field and using this data to infer the density ...
Intrusion Detection in IoT Data Streams based onEMNCD with Concept Drift
Intrusion Detection in IoT Data Streams based onEMNCD with Concept Drift
Abstract With the widespread application of smart devices, the security of IoT systems faces entirely new challenges. The IoT data stream operates in a non-stationary, dyna...

Back to Top