Study of runaway electrons using dosimetry of hard x-ray radiations in Damavand tokamak

View through CrossRef
In this work several studies have been conducted on hard x-ray emissions of Damavand tokamak based on radiation dosimetry using the Thermoluminescence method. The goal was to understand interactions of runaway electrons with plasma particles, vessel wall, and plasma facing components. Total of 354 GR-200 (LiF:Mg,Cu,P) thermoluminescence dosimeter (TLD) crystals have been placed on 118 points – three TLDs per point – to map hard x-ray radiation doses on the exterior of the vacuum vessel. Results show two distinctive levels of x-ray radiations doses on the exterior of the vessel. The low-dose area on which measured dose is about 0.5 mSv/shot. In the low-dose area there is no particular component inside the vessel. On the contrary, on high-dose area of the vessel, x-ray radiations dose exceeds 30 mSv/shot. The high-dose area coincides with the position of limiters, magnetic probe ducts, and vacuum vessel intersections. Among the high-dose areas, the highest level of dose is measured in the position of the limiter, which could be due to its direct contact with the plasma column and with runaway electrons. Direct collisions of runaway electrons with the vessel wall and plasma facing components make a major contribution for production of hard x-ray photons in Damavand tokamak.
Title: Study of runaway electrons using dosimetry of hard x-ray radiations in Damavand tokamak
Description:
In this work several studies have been conducted on hard x-ray emissions of Damavand tokamak based on radiation dosimetry using the Thermoluminescence method.
The goal was to understand interactions of runaway electrons with plasma particles, vessel wall, and plasma facing components.
Total of 354 GR-200 (LiF:Mg,Cu,P) thermoluminescence dosimeter (TLD) crystals have been placed on 118 points – three TLDs per point – to map hard x-ray radiation doses on the exterior of the vacuum vessel.
Results show two distinctive levels of x-ray radiations doses on the exterior of the vessel.
The low-dose area on which measured dose is about 0.
5 mSv/shot.
In the low-dose area there is no particular component inside the vessel.
On the contrary, on high-dose area of the vessel, x-ray radiations dose exceeds 30 mSv/shot.
The high-dose area coincides with the position of limiters, magnetic probe ducts, and vacuum vessel intersections.
Among the high-dose areas, the highest level of dose is measured in the position of the limiter, which could be due to its direct contact with the plasma column and with runaway electrons.
Direct collisions of runaway electrons with the vessel wall and plasma facing components make a major contribution for production of hard x-ray photons in Damavand tokamak.

Related Results

Nanophotonics with charged particles
Nanophotonics with charged particles
(English) Among the fundamental constituents of matter, charged particles such electrons and positrons are leading protagonists in physical phenomena associated with small (~ meV) ...
Modeling terrestrial gamma-ray flashes observed by ASIM
Modeling terrestrial gamma-ray flashes observed by ASIM
<p>The Atmosphere-Space Interactions Monitor (ASIM) on the International Space Station is providing important observations of terrestrial gamma-ray flashes (TGFs), in...
Identification and control of plasma vertical position using neural network in Damavand tokamak
Identification and control of plasma vertical position using neural network in Damavand tokamak
In this work, a nonlinear model is introduced to determine the vertical position of the plasma column in Damavand tokamak. Using this model as a simulator, a nonlinear neural netwo...
Measurements of the runaway electron energy during disruptions in the tokamak TEXTOR
Measurements of the runaway electron energy during disruptions in the tokamak TEXTOR
Calorimetric measurements of the total runaway electron energy are carried out using a reciprocating probe during induced TEXTOR disruptions. A comparison with the energy inferred ...
Technologies for retrospective radiation dosimetry
Technologies for retrospective radiation dosimetry
Abstract Radiation dosimetry is an important task for assessing the biological damages created in human being due to ionising radiation exposure. Ionising radiation ...
How background gases can delay the onset of the runaway greenhouse? Insights from 1D and 3D modeling.
How background gases can delay the onset of the runaway greenhouse? Insights from 1D and 3D modeling.
) IntroductionIf an Earth-like planet with a large amount of water is drifted towards its host star, the surface temperature increases, which leads the atmosphere to enter a catast...
Whistler heat flux instability governed interaction of anisotropic beam electrons in electromagnetic Vlasov simulations
Whistler heat flux instability governed interaction of anisotropic beam electrons in electromagnetic Vlasov simulations
The kinetic instability of whistlers in a warm plasma, arising from electron temperature anisotropy with respect to directions parallel and perpendicular to the magnetizing field, ...
Etched Track Techniques in Radiation Dosimetry
Etched Track Techniques in Radiation Dosimetry
Abstract Conventional detectors used in radiation protection dosimetry (for a given amount of energy deposited in their macroscopic volumes) are most sensitive to sp...