Javascript must be enabled to continue!
Using Machine Learning to Predict Five-Year Reintervention Risk in Type B Aortic Dissection Patients After Thoracic Endovascular Aortic Repair
View through CrossRef
Purpose: Type B aortic dissection (TBAD) is a high-risk disease, commonly treated with thoracic endovascular aortic repair (TEVAR). However, for the long-term follow-up, it is associated with a high 5-year reintervention rate for patients after TEVAR. There is no accurate definition
of prognostic risk factors for TBAD in medical guidelines, and there is no scientific judgment standard for patients’ quality of life or survival outcome in the next five years in clinical practice. A large amount of medical data features makes prognostic analysis difficult. However,
machine learning (ML) permits lots of objective data features to be considered for clinical risk stratification and patient management. We aimed to predict the 5-year prognosis in TBAD after TEVAR by Ml, based on baseline, stent characteristics and computed tomography angiography (CTA) imaging
data, and provided a certain degree of scientific basis for prognostic risk score and stratification in medical guidelines. Materials and Methods: Dataset we recorded was obtained from 172 TBAD patients undergoing TEVAR. Totally 40 features were recorded, including 14 baseline, 5 stent
characteristics and 21 CTA imaging data. Information gain (IG) was used to select features highly associated with adverse outcome. Then, the Gradient Boost classifier was trained using grid search and stratified 5-fold cross-validation, and Its predictive performance was evaluated by the area
under the curve (AUC) in the receiver operating characteristic (ROC). Results: Totally 60 patients underwent reintervention during follow-up. Combing 24 features selected by IG, ML model predicted prognosis well in TBAD after TEVAR, with an AUC of 0.816 and a 95% confidence interval
of 0.797 to 0.837. Reintervention rate of prediction was slightly higher than the actual (48.2% vs. 34.8%). Conclusion: Machine learning, which combined with baseline, stent characteristics and CTA imaging data for personalized risk computations, effectively predicted reintervention
risk in TBAD patients after TEVAR in 5-year follow-up. The model could be used to efficiently assist the clinical management of TBAD patients and prompt high-risk factors.
American Scientific Publishers
Title: Using Machine Learning to Predict Five-Year Reintervention Risk in Type B Aortic Dissection Patients After Thoracic Endovascular Aortic Repair
Description:
Purpose: Type B aortic dissection (TBAD) is a high-risk disease, commonly treated with thoracic endovascular aortic repair (TEVAR).
However, for the long-term follow-up, it is associated with a high 5-year reintervention rate for patients after TEVAR.
There is no accurate definition
of prognostic risk factors for TBAD in medical guidelines, and there is no scientific judgment standard for patients’ quality of life or survival outcome in the next five years in clinical practice.
A large amount of medical data features makes prognostic analysis difficult.
However,
machine learning (ML) permits lots of objective data features to be considered for clinical risk stratification and patient management.
We aimed to predict the 5-year prognosis in TBAD after TEVAR by Ml, based on baseline, stent characteristics and computed tomography angiography (CTA) imaging
data, and provided a certain degree of scientific basis for prognostic risk score and stratification in medical guidelines.
Materials and Methods: Dataset we recorded was obtained from 172 TBAD patients undergoing TEVAR.
Totally 40 features were recorded, including 14 baseline, 5 stent
characteristics and 21 CTA imaging data.
Information gain (IG) was used to select features highly associated with adverse outcome.
Then, the Gradient Boost classifier was trained using grid search and stratified 5-fold cross-validation, and Its predictive performance was evaluated by the area
under the curve (AUC) in the receiver operating characteristic (ROC).
Results: Totally 60 patients underwent reintervention during follow-up.
Combing 24 features selected by IG, ML model predicted prognosis well in TBAD after TEVAR, with an AUC of 0.
816 and a 95% confidence interval
of 0.
797 to 0.
837.
Reintervention rate of prediction was slightly higher than the actual (48.
2% vs.
34.
8%).
Conclusion: Machine learning, which combined with baseline, stent characteristics and CTA imaging data for personalized risk computations, effectively predicted reintervention
risk in TBAD patients after TEVAR in 5-year follow-up.
The model could be used to efficiently assist the clinical management of TBAD patients and prompt high-risk factors.
Related Results
Investigation of factors affecting reintervention after type A aortic dissection
Investigation of factors affecting reintervention after type A aortic dissection
Aim: Our study aims to share the reintervention results of patients who were operated with the diagnosis of Type A aortic dissection and to examine the factors that cause reinterve...
Presentation and Management of Cervical Thoracic Duct Cyst: A Systematic Review of the Literature
Presentation and Management of Cervical Thoracic Duct Cyst: A Systematic Review of the Literature
Abstract
Introduction
Thoracic duct cysts are an uncommon phenomenon, especially within the cervical region. Due to its limited reported cases, very little is known about its etiol...
Phrenic Nerve Block for Management of Post-Thoracic Outlet Decompression Cough: A Case Report and Literature Review
Phrenic Nerve Block for Management of Post-Thoracic Outlet Decompression Cough: A Case Report and Literature Review
Abstract
Introduction
Thoracic outlet syndrome is a group of disorders arising from compressive forces on the neurovascular bundle in that region due to different etiologies. This...
Diseases of the Aorta
Diseases of the Aorta
This review covers the major presentations affecting the aorta: aortic aneurysms (abdominal aortic aneurysms and thoracic aortic aneurysms), acute aortic syndromes (including aorti...
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Background: This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixation on renal functi...
Decreased expression of fibulin-4 in aortic wall of aortic dissection
Decreased expression of fibulin-4 in aortic wall of aortic dissection
In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10...
OC24 ENDOVASCULAR SURGERY FOR ACUTE THORACIC AORTIC SYNDROMES
OC24 ENDOVASCULAR SURGERY FOR ACUTE THORACIC AORTIC SYNDROMES
Background and Aim:
Surgery of thoracic aortic emergencies is challenging and carries significant high morbidity and mortality rate. In the last decade, Thoracic EndoVa...
Management strategies for acute type A aortic dissection complicated by limb malperfusion
Management strategies for acute type A aortic dissection complicated by limb malperfusion
Abstract
Objective: Acute type A aortic dissection complicated by limb malperfusion confers a risk of mortality to the patients. And,debates still exist about how to manage...