Javascript must be enabled to continue!
Burning Blended Coal of Indonesia Lignite and Vietnam Anthracite on a Face-Fired 600MW Boiler Original Designed for Bituminous Coal
View through CrossRef
Elemental research of burning blended coal of Indonesia Lignite and Vietnam anthracite on a face-fired 600MW supercritical boiler is performed, which is original designed for burning high-quality bituminous coal. Maximum ratio of Vietnam anthracite can be 40 percent. With the increase of the ratio of the anthracite, the size of residue particles and the ratio of unburned carbon in residues (UBCRs) rise up markedly, the slag formation of Indonesia Lignite alleviate. The results reveal: the burnout of anthracite is more difficult than its ignition, the key way to solve this problem is to control Fineness of Pulverized Coal Powder (FPCP) of the blended coal according requirements of anthracite, but to control the Primary Air (PA) outlet temperature of mill and the mass ratio of PA to coal as flammable coal Lignite. Besides, Secondary Air (SA) Distribution mode of Centralized Oxygen Feeding(COF), Big Swirl Intensity also have obvious effects the combustion of blended coal.
Title: Burning Blended Coal of Indonesia Lignite and Vietnam Anthracite on a Face-Fired 600MW Boiler Original Designed for Bituminous Coal
Description:
Elemental research of burning blended coal of Indonesia Lignite and Vietnam anthracite on a face-fired 600MW supercritical boiler is performed, which is original designed for burning high-quality bituminous coal.
Maximum ratio of Vietnam anthracite can be 40 percent.
With the increase of the ratio of the anthracite, the size of residue particles and the ratio of unburned carbon in residues (UBCRs) rise up markedly, the slag formation of Indonesia Lignite alleviate.
The results reveal: the burnout of anthracite is more difficult than its ignition, the key way to solve this problem is to control Fineness of Pulverized Coal Powder (FPCP) of the blended coal according requirements of anthracite, but to control the Primary Air (PA) outlet temperature of mill and the mass ratio of PA to coal as flammable coal Lignite.
Besides, Secondary Air (SA) Distribution mode of Centralized Oxygen Feeding(COF), Big Swirl Intensity also have obvious effects the combustion of blended coal.
Related Results
Change in reservoir structure of different lithotypes of lignite with dehydration
Change in reservoir structure of different lithotypes of lignite with dehydration
<p>Find out the changes in lignite properties accompanying dehydration will not only benefit the development of lignite CBM, but also play a guiding role in the under...
Biodiversity potential and scientific basis for conservation in the Song Hinh - Tay Hoa area, Dak Lak province, Vietnam
Biodiversity potential and scientific basis for conservation in the Song Hinh - Tay Hoa area, Dak Lak province, Vietnam
The Song Hinh - Tay Hoa area harbors exceptional ecological and biodiversity values. Two characteristic forest ecosystems are represented: lowland and mid-montane evergreen tropica...
Nanoscale pore structure in anthracite coals and its effect on methane adsorption capacity
Nanoscale pore structure in anthracite coals and its effect on methane adsorption capacity
Although significant amounts of methane are present in anthracite coal seams, coalbed methane resources cannot be extracted effectively and quickly. This study mainly focused on in...
Research on the Modification of Coal Adaptability and Carbon Emissions Reduction Technology for Coal-Fired Boilers
Research on the Modification of Coal Adaptability and Carbon Emissions Reduction Technology for Coal-Fired Boilers
In order to solve the problems of the high temperature of flue gas, low boiler efficiency, and the high concentration of nitrogen oxide (NOx) emissions for a 330 MW boiler fired wi...
LOCATION OF THE LIGNITE FROM THE DĘBY SZLACHECKIE DEPOSIT IN THE INTERNATIONAL CLASSIFICATIONS
LOCATION OF THE LIGNITE FROM THE DĘBY SZLACHECKIE DEPOSIT IN THE INTERNATIONAL CLASSIFICATIONS
The Dęby Szlacheckie lignite deposit is one of the prospective deposits of Poland. It is located between the Pomeranian Trough and Łódź Basin. The abovementioned deposit is classif...
CO2 Emission Calculation and Emission Characteristics Analysis of Typical 600MW Coal-fired Thermal Power Unit
CO2 Emission Calculation and Emission Characteristics Analysis of Typical 600MW Coal-fired Thermal Power Unit
In order to effectively reduce the total CO2 emissions of coal-fired power plants and reduce greenhouse gas emissions, the relevant data of a typical 600MW coal-fired power plant i...
Anthracite nanoporous carbons obtained by nitric acid intercalation followed by alkaline activation
Anthracite nanoporous carbons obtained by nitric acid intercalation followed by alkaline activation
The aim of the work is to determine the effect of nitric acid intercalation of anthracite on the porous structure and adsorption properties of activated carbons (ACs) obtained by a...