Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Floating Subscapularis Tear: A Variation of the Partial Subscapularis Tear

View through CrossRef
A variation of subscapularis tear has been identified, named floating subscapularis, where the tendon is completely detached from the lesser tuberosity but is continuous with the tissue covering the bicipital groove. An accurate diagnosis can be made using arthroscopic observation with passive external and internal rotation of the affected shoulder, which shows mismatched movement between the humerus and the subscapularis tendon. The purpose of this study is to examine the prevalence of this particular tear pattern. Clinical records during the study period (from January 2011 to December 2017) were retrospectively examined. Overall, 1295 arthroscopic rotator cuff repair procedures were performed. Among these, the subscapularis tendon was repaired in 448 cases, and 27 cases were diagnosed as floating subscapularis. The prevalence of floating subscapularis was 6% in the subscapularis repair population. This particular tear pattern has not previously been described and it seems to be ignored. The floating subscapularis is thought to be the tear of the deep layer preserving the superficial layer connected to the greater tuberosity by fibrous extension of the soft tissue covering the bicipital groove.
Title: Floating Subscapularis Tear: A Variation of the Partial Subscapularis Tear
Description:
A variation of subscapularis tear has been identified, named floating subscapularis, where the tendon is completely detached from the lesser tuberosity but is continuous with the tissue covering the bicipital groove.
An accurate diagnosis can be made using arthroscopic observation with passive external and internal rotation of the affected shoulder, which shows mismatched movement between the humerus and the subscapularis tendon.
The purpose of this study is to examine the prevalence of this particular tear pattern.
Clinical records during the study period (from January 2011 to December 2017) were retrospectively examined.
Overall, 1295 arthroscopic rotator cuff repair procedures were performed.
Among these, the subscapularis tendon was repaired in 448 cases, and 27 cases were diagnosed as floating subscapularis.
The prevalence of floating subscapularis was 6% in the subscapularis repair population.
This particular tear pattern has not previously been described and it seems to be ignored.
The floating subscapularis is thought to be the tear of the deep layer preserving the superficial layer connected to the greater tuberosity by fibrous extension of the soft tissue covering the bicipital groove.

Related Results

Rare Subscapularis Anterior Leading Edge Tear following Traumatic Posterior Shoulder Dislocation: A Case Report
Rare Subscapularis Anterior Leading Edge Tear following Traumatic Posterior Shoulder Dislocation: A Case Report
Introduction: A patient presented with traumatic posterior shoulder dislocation and underwent a diagnostic arthroscopy, where an acute subscapularis anterior leading edge tear was ...
Evaluation of tear film instability pre and post corneal collagen cross-linking procedure in keratoconus patients
Evaluation of tear film instability pre and post corneal collagen cross-linking procedure in keratoconus patients
Purpose: To evaluate tear film instability in keratoconus patients pre and post CXL procedure. Study design: Prospective cross-sectional study. Place and duration of study: Study...
<b>Regional Tear Film Instability in Dry Eye Disease: A Comparative Analysis of Central and Inferior Tear Breakup Time</b>
<b>Regional Tear Film Instability in Dry Eye Disease: A Comparative Analysis of Central and Inferior Tear Breakup Time</b>
Background: Dry eye disease is a multifactorial ocular surface disorder characterized by tear film instability, ocular discomfort, and visual disturbance. Conventional tear breakup...
Kajian Pengembangan Sediaan Floating Sustained Release Tablet
Kajian Pengembangan Sediaan Floating Sustained Release Tablet
Abstract. Floating sustained release tablets were developed to increase the elimination half-life and bioavailability of the drug because it is able to release the active substance...
A STUDY TO EVALUATE THE TEAR FILM CHANGES IN PATIENTS WITH PTERYGIUM.
A STUDY TO EVALUATE THE TEAR FILM CHANGES IN PATIENTS WITH PTERYGIUM.
Introduction: Pterygium is a degenerative condition of the subconjunctival tissues which proliferate as vascularized granulation tissue to invade the cornea, destroying the superc...
Design of Floating HPMC Matrix Tablets: Effect of Formulation Variables on Floating Properties and Drug Release
Design of Floating HPMC Matrix Tablets: Effect of Formulation Variables on Floating Properties and Drug Release
Floating matrix tablets were designed and evaluated. Theophylline was used as a model drug. The system was prepared by mixing drug, matrix-forming polymer (hydroxypropyl methylcell...
Association of Supraspinatus Tear Type and Localisation Between Humeral Head Bone Cyst
Association of Supraspinatus Tear Type and Localisation Between Humeral Head Bone Cyst
Objective: This study aims to comprehensively explore the association between different types and locations of supraspinatus tendon tears and the presence of humeral head bone cyst...

Back to Top