Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Abstract 659: A novel manganese MRI contrast agent (PyC3A) for the evaluation of hepatic neoplasms

View through CrossRef
Abstract Introduction: Magnetic resonance imaging (MRI) is routinely used to diagnosis hepatic neoplasms. However, Gadolinium (Gd) is contraindicated in patients with severe renal impairment, and recent evidence also suggests Gd accumulates in brain tissue after repeated contrast injections. Manganese (Mn2+) is a paramagnetic ion that is cleared via biliary excretion, and provides an ideal alternative to Gd-based MR contrast agents. We present a novel Mn-based contrast agent, [Mn(PyC3A)(H2O)]- (referred to as PyC3A), and compare its efficacy to gadoxetic acid (Eovist) by imaging orthotopically implanted colorectal cancer hepatic metastases in mice. Methods: Male BALB/c mice (n = 8) were injected in the left lobe of the liver with 5x104 MC26/MCA-26 murine colon carcinoma cells, and were imaged on postoperative day 10 using a 4.7T MR scanner with PyC3A and gadoxetic acid (Eovist) 24 hrs apart. Signal contrast-to-noise ratio (CNR) was calculated for normal liver relative to tumor for each probe and compared. Results: Relaxivity of PyC3A in blood plasma was shown to be comparable to commercial Gd contrast agents. Biodistribution analysis confirmed that PyC3A clears via a mixed renal/hepatobiliary pathway with greater than 99% clearance within 24 hours. For imaging hepatic metastases, all mice survived to the study endpoint and developed radiographically discernible tumors (5 ± 2 mm diameter) without evidence of carcinomatosis. Calculated CNRs for liver relative to tumor for all recorded times are shown in Table 1. There was no difference in CNR between gadoxetic acid and PyC3A for all time points, suggesting near-equivalent enhancement of normal liver and tumor by both probes. Conclusions: PyC3A provides resolution of metastatic liver metastases that is comparable to gadoxetic acid. PyC3A may provide a safe and effective alternative to Gd constrast agents for imaging hepatic neoplasms in patients with renal impairment. Table 1. Contrast-to-Noise Ratio (CNR) of Normal Liver Relative to TumorTime (minutes post injection)Gadoxetic AcidPyC3Ap-value02.61 ± 1.082.60 ± 1.640.9237.72 ± 4.677.53 ± 3.020.9387.85 ± 3.898.85 ± 4.430.66138.02 ± 3.987.62 ± 5.490.88189.79 ± 4.175.60 ± 3.080.06238.72 ± 4.167.03 ± 2.060.36 Citation Format: Derek J. Erstad, Ian Ramsay, Mozhdeh Sojoodi, Christian Farrar, NIcholas J. Rotile, Shen Li, Sarani Ghoshal, Lanuti Michael, Peter Caravan, Kenneth K. Tanabe, Bryan C. Fuchs, Eric Gale. A novel manganese MRI contrast agent (PyC3A) for the evaluation of hepatic neoplasms [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2018; 2018 Apr 14-18; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2018;78(13 Suppl):Abstract nr 659.
Title: Abstract 659: A novel manganese MRI contrast agent (PyC3A) for the evaluation of hepatic neoplasms
Description:
Abstract Introduction: Magnetic resonance imaging (MRI) is routinely used to diagnosis hepatic neoplasms.
However, Gadolinium (Gd) is contraindicated in patients with severe renal impairment, and recent evidence also suggests Gd accumulates in brain tissue after repeated contrast injections.
Manganese (Mn2+) is a paramagnetic ion that is cleared via biliary excretion, and provides an ideal alternative to Gd-based MR contrast agents.
We present a novel Mn-based contrast agent, [Mn(PyC3A)(H2O)]- (referred to as PyC3A), and compare its efficacy to gadoxetic acid (Eovist) by imaging orthotopically implanted colorectal cancer hepatic metastases in mice.
Methods: Male BALB/c mice (n = 8) were injected in the left lobe of the liver with 5x104 MC26/MCA-26 murine colon carcinoma cells, and were imaged on postoperative day 10 using a 4.
7T MR scanner with PyC3A and gadoxetic acid (Eovist) 24 hrs apart.
Signal contrast-to-noise ratio (CNR) was calculated for normal liver relative to tumor for each probe and compared.
Results: Relaxivity of PyC3A in blood plasma was shown to be comparable to commercial Gd contrast agents.
Biodistribution analysis confirmed that PyC3A clears via a mixed renal/hepatobiliary pathway with greater than 99% clearance within 24 hours.
For imaging hepatic metastases, all mice survived to the study endpoint and developed radiographically discernible tumors (5 ± 2 mm diameter) without evidence of carcinomatosis.
Calculated CNRs for liver relative to tumor for all recorded times are shown in Table 1.
There was no difference in CNR between gadoxetic acid and PyC3A for all time points, suggesting near-equivalent enhancement of normal liver and tumor by both probes.
Conclusions: PyC3A provides resolution of metastatic liver metastases that is comparable to gadoxetic acid.
PyC3A may provide a safe and effective alternative to Gd constrast agents for imaging hepatic neoplasms in patients with renal impairment.
Table 1.
Contrast-to-Noise Ratio (CNR) of Normal Liver Relative to TumorTime (minutes post injection)Gadoxetic AcidPyC3Ap-value02.
61 ± 1.
082.
60 ± 1.
640.
9237.
72 ± 4.
677.
53 ± 3.
020.
9387.
85 ± 3.
898.
85 ± 4.
430.
66138.
02 ± 3.
987.
62 ± 5.
490.
88189.
79 ± 4.
175.
60 ± 3.
080.
06238.
72 ± 4.
167.
03 ± 2.
060.
36 Citation Format: Derek J.
Erstad, Ian Ramsay, Mozhdeh Sojoodi, Christian Farrar, NIcholas J.
Rotile, Shen Li, Sarani Ghoshal, Lanuti Michael, Peter Caravan, Kenneth K.
Tanabe, Bryan C.
Fuchs, Eric Gale.
A novel manganese MRI contrast agent (PyC3A) for the evaluation of hepatic neoplasms [abstract].
In: Proceedings of the American Association for Cancer Research Annual Meeting 2018; 2018 Apr 14-18; Chicago, IL.
Philadelphia (PA): AACR; Cancer Res 2018;78(13 Suppl):Abstract nr 659.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Draft Recommendations on Classification of Rodent Neoplasms for Peto Analysis
Draft Recommendations on Classification of Rodent Neoplasms for Peto Analysis
The Executive Committee of the Society of Toxicologic Pathology appointed an ad hoc working group to review the current use of the Peto model for statistical analysis of rodent car...
Properties of biologically formed manganese oxide in relation to soil manganese
Properties of biologically formed manganese oxide in relation to soil manganese
Manganese oxide, produced from the oxidation of manganous ions by bacteria at pH 6.5, was extracted with solutions commonly used to estimate the availability of soil manganese to p...
Management of childhood esophageal varices: learnings from an advanced medical centre
Management of childhood esophageal varices: learnings from an advanced medical centre
Background: Variceal bleeding represents a significant clinical emergency with potential life-threatening implications in infants and children. Endoscopic band ligation is the stan...
The assessment of available manganese and aluminium status in acid soils under subterranean clover pastures of various ages
The assessment of available manganese and aluminium status in acid soils under subterranean clover pastures of various ages
Three methods of estimating available manganese and aluminium status in acid soils were compared on three groups of soils from the Pejar district near Goulburn, New South Wales in ...
A manganese(II)-Based Responsive Contrast Agent Detects Glucose- Stimulated Zinc Secretion from the Mouse Pancreas and Prostate by MRI.
A manganese(II)-Based Responsive Contrast Agent Detects Glucose- Stimulated Zinc Secretion from the Mouse Pancreas and Prostate by MRI.
A Mn(II)-based zinc-sensitive MRI contrast agent, Mn(PyC3A)-BPEN, was prepared and characterized and the agent was used in imaging experiments to detect glucose-stimulated zinc sec...
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Abstract Background:To explore whether there is abnormality of neonatal brains’ MRI and BAEP with different bilirubin levels, and to provide an objective basis for early di...
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Abstract Background:To explore whether there is abnormality of neonatal brains’ MRI and BAEP with different bilirubin levels, and to provide an objective basis for early di...

Back to Top