Javascript must be enabled to continue!
A Monolithic Spatial Heterodyne Raman Spectrometer: Initial Tests
View through CrossRef
A monolithic spatial heterodyne Raman spectrometer (mSHRS) is described, where the optical components of the spectrometer are bonded to make a small, stable, one-piece structure. This builds on previous work, where we described bench top spatial heterodyne Raman spectrometers (SHRS), developed for planetary spacecraft and rovers. The SHRS is based on a fixed grating spatial heterodyne spectrometer (SHS) that offers high spectral resolution and high light throughput in a small footprint. The resolution of the SHS is not dependent on a slit, and high resolution can be realized without using long focal length dispersing optics since it is not a dispersive device. Thus, the SHS can be used as a component in a compact Raman spectrometer with high spectral resolution and a large spectral range using a standard 1024 element charge-coupled device. Since the resolution of the SHRS is not dependent on a long optical path, it is amenable to the use of monolithic construction techniques to make a compact and robust device. In this paper, we describe the use of two different monolithic SHSs (mSHSs), with Littrow wavelengths of 531.6 nm and 541.05 nm, each about 3.5 × 3.5 × 2.5 cm in size and weighing about 80 g, in a Raman spectrometer that provides ∼3500 cm−1 spectral range with 4–5 cm−1 and 8–9 cm−1 resolution, for 600 grooves/mm and 150 grooves/mm grating-based mSHS devices, respectively. In this proof of concept paper, the stability, spectral resolution, spectral range, and signal-to-noise ratio of the mSHRS spectrometers are compared to our bench top SHRS that uses free-standing optics, and signal to noise comparisons are also made to a Kaiser Holospec f/1.8 Raman spectrometer.
SAGE Publications
Title: A Monolithic Spatial Heterodyne Raman Spectrometer: Initial Tests
Description:
A monolithic spatial heterodyne Raman spectrometer (mSHRS) is described, where the optical components of the spectrometer are bonded to make a small, stable, one-piece structure.
This builds on previous work, where we described bench top spatial heterodyne Raman spectrometers (SHRS), developed for planetary spacecraft and rovers.
The SHRS is based on a fixed grating spatial heterodyne spectrometer (SHS) that offers high spectral resolution and high light throughput in a small footprint.
The resolution of the SHS is not dependent on a slit, and high resolution can be realized without using long focal length dispersing optics since it is not a dispersive device.
Thus, the SHS can be used as a component in a compact Raman spectrometer with high spectral resolution and a large spectral range using a standard 1024 element charge-coupled device.
Since the resolution of the SHRS is not dependent on a long optical path, it is amenable to the use of monolithic construction techniques to make a compact and robust device.
In this paper, we describe the use of two different monolithic SHSs (mSHSs), with Littrow wavelengths of 531.
6 nm and 541.
05 nm, each about 3.
5 × 3.
5 × 2.
5 cm in size and weighing about 80 g, in a Raman spectrometer that provides ∼3500 cm−1 spectral range with 4–5 cm−1 and 8–9 cm−1 resolution, for 600 grooves/mm and 150 grooves/mm grating-based mSHS devices, respectively.
In this proof of concept paper, the stability, spectral resolution, spectral range, and signal-to-noise ratio of the mSHRS spectrometers are compared to our bench top SHRS that uses free-standing optics, and signal to noise comparisons are also made to a Kaiser Holospec f/1.
8 Raman spectrometer.
Related Results
.57μm Active Laser Heterodyne Spectrometer and CO2 Concentration Measurement
.57μm Active Laser Heterodyne Spectrometer and CO2 Concentration Measurement
CO2 is an important greenhouse gas(GHG) that affects the Earth's atmosphere, and continuous measurement of CO2 helps understand its sources and sinks. The passive laser heterodyne ...
Design and Development of the VenSpec-H Instrument
Design and Development of the VenSpec-H Instrument
Introduction: VenSpec-H (Venus Spectrometer with High resolution), part of ESA’s EnVision M5 mission to Venus, is currently in Phase A (started in January 2019) ...
Design and Implementation of Matryoshka-type Neutron Spectrometer
Design and Implementation of Matryoshka-type Neutron Spectrometer
Abstract
Aiming at portability and mobility, the design and implementation of a portable neutron spectrometer, namely the Matryoshka-type Neutron Spectrometer, was comple...
RELEVANCE OF USING MODERN TECHNOLOGIES IN MONOLITHIC CONSTRUCTION
RELEVANCE OF USING MODERN TECHNOLOGIES IN MONOLITHIC CONSTRUCTION
Problem statement.Monolithic construction is one of the most common and most effective methods of building and construction. The introduction of the latest technologies in this typ...
Squeezing-enhanced Raman spectroscopy
Squeezing-enhanced Raman spectroscopy
AbstractThe sensitivity of classical Raman spectroscopy methods, such as coherent anti-stokes Raman spectroscopy (CARS) or stimulated Raman spectroscopy (SRS), is ultimately limite...
Miniature Broadband NIR Spectrometer Based on FR4 Electromagnetic Scanning Micro-Grating
Miniature Broadband NIR Spectrometer Based on FR4 Electromagnetic Scanning Micro-Grating
This paper presents a miniaturized, broadband near-infrared (NIR) spectrometer with a flame-retardant 4 (FR4)-based scanning micrograte. A 90° off-axis parabolic mirror and a cross...
Systematical structural analysis of monolithic domes
Systematical structural analysis of monolithic domes
Monolithic dome structures were built in the 1970s in Europe and America. These dome structures share common benefits of being cost efficient, earth-friendly, extremely durable, an...
Temperature dependence of the raman spectrum of DNA. II. Raman signatures of premelting and melting transitions of poly(dA)·poly(dT) and comparison with poly(dA‐dT)·poly(dA‐dT)*
Temperature dependence of the raman spectrum of DNA. II. Raman signatures of premelting and melting transitions of poly(dA)·poly(dT) and comparison with poly(dA‐dT)·poly(dA‐dT)*
AbstractThe temperature dependence of the Raman spectrum of poly(dA)·poly(dT) (dA: deoxyadenosine; dT: thymidine), a model for DNA containing consecutive adenine·thymine (A·T) pair...

