Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Microcantilever Arrays for Multiplexed Biomolecular Analysis

View through CrossRef
An accurate, efficient, and quantitative method for detection of multiple biomolecules, such as DNA and proteins, would benefit many bio-medical applications. These applications include diagnostics of complex diseases such as cancer, drug discovery, and development of fundamental scientific knowledge regarding signaling pathways. We have developed a chip-level microcantilever array designed for high-throughput biomolecular analysis. In particular, biological reactions on one surface of a microcantilever beam change its surface tension due to intermolecular energetic and entropic interactions. These interactions generate sufficient torque to deflect the cantilever beam. Integration of microfluid cells on the chip allows for individual functionalization of each cantilever. Each cantilever is designed to respond uniquely to a specific target analyte allowing for simultaneous and quantitative analysis of multiple bio-molecules. Experiments testing the physical response of the microarray describe the repeatability of the cantilevers while providing information regarding the limits on the detection time for reaction-induced deflections to dominate over random drift of the cantilevers. Statistical analysis shows that the cantilevers exhibit thermomechanical sensitivity within ±7% variation. The maximum observed trend of the long-term drift is about 2.1nm/min, which suggests reactions should be completed within 10 minutes, for a reliable bioassay.
Title: Microcantilever Arrays for Multiplexed Biomolecular Analysis
Description:
An accurate, efficient, and quantitative method for detection of multiple biomolecules, such as DNA and proteins, would benefit many bio-medical applications.
These applications include diagnostics of complex diseases such as cancer, drug discovery, and development of fundamental scientific knowledge regarding signaling pathways.
We have developed a chip-level microcantilever array designed for high-throughput biomolecular analysis.
In particular, biological reactions on one surface of a microcantilever beam change its surface tension due to intermolecular energetic and entropic interactions.
These interactions generate sufficient torque to deflect the cantilever beam.
Integration of microfluid cells on the chip allows for individual functionalization of each cantilever.
Each cantilever is designed to respond uniquely to a specific target analyte allowing for simultaneous and quantitative analysis of multiple bio-molecules.
Experiments testing the physical response of the microarray describe the repeatability of the cantilevers while providing information regarding the limits on the detection time for reaction-induced deflections to dominate over random drift of the cantilevers.
Statistical analysis shows that the cantilevers exhibit thermomechanical sensitivity within ±7% variation.
The maximum observed trend of the long-term drift is about 2.
1nm/min, which suggests reactions should be completed within 10 minutes, for a reliable bioassay.

Related Results

Analysis of ARROW Waveguide based Microcantilever for Sensing Application
Analysis of ARROW Waveguide based Microcantilever for Sensing Application
Abstract Analysis of microcantilever beam and ARROW microcantilever waveguides are presented in this work. The microcantilever is simulated by using the silicon nitride mat...
Resonance Frequency Change in Microcantilever-Based Sensor due to Humidity Variation
Resonance Frequency Change in Microcantilever-Based Sensor due to Humidity Variation
Microcantilever-based sensors have attracted interest in the last decade because of their small size, rapid detection and high sensitivity. This sensor can be applied in the many f...
Assessing Array-Type Differences in Cochlear Implant Users Using the Panoramic ECAP Method
Assessing Array-Type Differences in Cochlear Implant Users Using the Panoramic ECAP Method
OBJECTIVES: Cochlear-implant companies manufacture devices with different electrode array types. Some arrays have a straight geometry designed for minimal neuronal trauma, while ot...
Self-Standing 3D Thin Film Cathodes for Micobatteries
Self-Standing 3D Thin Film Cathodes for Micobatteries
While the microelectronic industry is advancing at a rapid pace with smaller and smaller devices, the implementation of microelectro-mechanical systems (MEMS) on the market strongl...
Peculiarities of adaptive signal processing in circular antenna arrays
Peculiarities of adaptive signal processing in circular antenna arrays
Formulation of the problem. Today, antenna arrays are often used as directional antennas of different radio systems. The main advantages of the such antennas over the mechanically ...
Heat dissipation analysis of bendable AlGaInP micro-LED arrays
Heat dissipation analysis of bendable AlGaInP micro-LED arrays
A strategy for fabricating bendable AlGaInP light emitting diode (LED) arrays is presented in this paper. Sample LED arrays with 8 × 8 pixels were fabricated and subjected to bendi...
Evaluation of Thermally Crosslinked Poly(Acrylic Acid-Co-Maleic Acid) (PAMA)/Poly(Vinyl Alcohol) (PVA) Microneedle Arrays
Evaluation of Thermally Crosslinked Poly(Acrylic Acid-Co-Maleic Acid) (PAMA)/Poly(Vinyl Alcohol) (PVA) Microneedle Arrays
This study aimed to evaluate the optimal conditions for crosslinked of PAMA/PVA microneedle (MN) arrays. Poly (acrylic acid-co-maleic acid) (PAMA)/poly (vinyl alcohol) (PVA) MN arr...
Organization of telomere sequences in birds: evidence for arrays of extreme length and for in vivo shortening
Organization of telomere sequences in birds: evidence for arrays of extreme length and for in vivo shortening
Telomeres are the specialized ends of chromosomes consisting of highly conserved repeat (5′-TTAGGG-3′)<sub>n</sub> sequences. Lack of information regarding the existenc...

Back to Top