Javascript must be enabled to continue!
Real-time ultrasound-guided thoracentesis simulation using an optical see-through head-mounted display: a proof-of-concept study
View through CrossRef
Aim: This study aimed to examine the feasibility and potential benefits of an optical see-through headmounted display (OST-HMD) during real-time ultrasound-guided thoracentesis simulations. Material and methods: Six physicians performed a thoracentesis simulation using an OST-HMD and a wireless image transmission system. The time required, puncture needle visibility, pleural fluid collection success rate, and head movement during the procedure using a smart glass equipped with an inertial measurement unit were all recorded and compared with and without the HMD. Results: Study participants successfully extracted effusions in all procedures. The use of OST-HMD did not significantly affect the time of the procedure, but notably decreased the horizontal and vertical head movements during the procedure. Conclusions: The study demonstrated the feasibility of using an OST-HMD in a simulated real-time ultrasoundguided thoracentesis procedure and showed the potential of HMD in thoracentesis to improve ergonomics and accuracy. Further research is necessary to confirm these findings.
Medical Communications Sp. z.o.o.
Title: Real-time ultrasound-guided thoracentesis simulation using an optical see-through head-mounted display: a proof-of-concept study
Description:
Aim: This study aimed to examine the feasibility and potential benefits of an optical see-through headmounted display (OST-HMD) during real-time ultrasound-guided thoracentesis simulations.
Material and methods: Six physicians performed a thoracentesis simulation using an OST-HMD and a wireless image transmission system.
The time required, puncture needle visibility, pleural fluid collection success rate, and head movement during the procedure using a smart glass equipped with an inertial measurement unit were all recorded and compared with and without the HMD.
Results: Study participants successfully extracted effusions in all procedures.
The use of OST-HMD did not significantly affect the time of the procedure, but notably decreased the horizontal and vertical head movements during the procedure.
Conclusions: The study demonstrated the feasibility of using an OST-HMD in a simulated real-time ultrasoundguided thoracentesis procedure and showed the potential of HMD in thoracentesis to improve ergonomics and accuracy.
Further research is necessary to confirm these findings.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Thoracentesis in advanced cancer patients with severe thrombocytopenia: Ultrasound guide improves safety and reduces bleeding risk
Thoracentesis in advanced cancer patients with severe thrombocytopenia: Ultrasound guide improves safety and reduces bleeding risk
AbstractBackgroundPatients with severe thrombocytopenia are considered at risk for bleeding during invasive procedures as thoracentesis. The use of ultrasound (US) significantly re...
Woningcorporaties en Vastgoedontwikkeling
Woningcorporaties en Vastgoedontwikkeling
This summary highlights the findings of the PhD-thesis ‘Woningcorporaties en Vastgoedontwikkeling: Fit for Use’ (‘Housing associations and Real Estate Development: Fit for Use?’). ...
COMPARISON OF REAL-TIME ULTRASOUND GUIDED THORACENTESIS WITH BLIND TECHNIQUE
COMPARISON OF REAL-TIME ULTRASOUND GUIDED THORACENTESIS WITH BLIND TECHNIQUE
Background: Pleural effusion, the abnormal accumulation of fluid in the pleural space, remains a frequent clinical and diagnostic challenge. Identifying its etiology and managing f...
Bounds on the sum of broadcast domination number and strong metric dimension of graphs
Bounds on the sum of broadcast domination number and strong metric dimension of graphs
Let [Formula: see text] be a connected graph of order at least two with vertex set [Formula: see text]. For [Formula: see text], let [Formula: see text] denote the length of an [Fo...
Outcome of Intermittent Thoracentesis versus Pigtail Catheter Drainage for Hepatic Hydrothorax
Outcome of Intermittent Thoracentesis versus Pigtail Catheter Drainage for Hepatic Hydrothorax
Background/Aims: The management of hepatic hydrothorax (HH) remains a challenging clinical scenario with suboptimal options. We investigated the effect and safety of pigtail cathet...
Impacto de los equipos hospitalarios multiprofesionales de acceso vascular guiado por ecografía
Impacto de los equipos hospitalarios multiprofesionales de acceso vascular guiado por ecografía
Introduction
Vascular access is essential for administering intravenous therapies in both hospital and outpatient settings.The traditional technique, based on palpation and visuali...
Determine the Frequency of Pneumothorax in Patients Undergoing Large Volume Thoracentesis
Determine the Frequency of Pneumothorax in Patients Undergoing Large Volume Thoracentesis
Background: Thoracentesis is a medical procedure used to remove excess fluid or air from the pleural space, the space between the lungs and the chest wall. Pleural effusion occurs ...