Javascript must be enabled to continue!
Electrical Connectors
View through CrossRef
Abstract
Electrical connectors are mechanical devices that connect wires, cables, printed circuit boards, and electronic components to each other and to related equipment. Electronic connectors are designed primarily for low power signal applications as in telecommunications and computers. Another category is the utility and industrial connectors used in power distribution systems. Almost all connectors that join two or more conductors have an insulating body or dielectric, most usually made of a plastic, which separates the contact elements. Connectors are used to make permanent joints or to allow separation and remating of the conductors. Connectors are composed of contact substrates which are generally metallic, contact finishes, lubricants, and an insultating shell. Insulators are also employed for multicontact connectors. The reliability and testing procedures for electrical connectors, together with the thermal, chemical, and mechanical mechanisms of connector failure, are discussed.
Title: Electrical Connectors
Description:
Abstract
Electrical connectors are mechanical devices that connect wires, cables, printed circuit boards, and electronic components to each other and to related equipment.
Electronic connectors are designed primarily for low power signal applications as in telecommunications and computers.
Another category is the utility and industrial connectors used in power distribution systems.
Almost all connectors that join two or more conductors have an insulating body or dielectric, most usually made of a plastic, which separates the contact elements.
Connectors are used to make permanent joints or to allow separation and remating of the conductors.
Connectors are composed of contact substrates which are generally metallic, contact finishes, lubricants, and an insultating shell.
Insulators are also employed for multicontact connectors.
The reliability and testing procedures for electrical connectors, together with the thermal, chemical, and mechanical mechanisms of connector failure, are discussed.
Related Results
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Experimental and theoretical study on shear performance of T-shaped and bulb flat shear connectors in composite structures
Experimental and theoretical study on shear performance of T-shaped and bulb flat shear connectors in composite structures
This study investigates the mechanical performance and theoretical design methods of T-shaped and bulb flat shear connectors in large-scale steel-concrete composite structures. The...
STRESS-STRAIN RELATIONSHIPS OF COMPOSITE FOAMED CONCRETE PANEL WITH DIFFERENT NUMBER OF SHEAR CONNECTORS UNDER COMPRESSION
STRESS-STRAIN RELATIONSHIPS OF COMPOSITE FOAMED CONCRETE PANEL WITH DIFFERENT NUMBER OF SHEAR CONNECTORS UNDER COMPRESSION
The present of the shear connectors with the sandwich composite foamed concrete panel system is to increase the strength of the panel. Therefore the objectives of experiment on eff...
DEFORMATION CAPACITY AND DUCTILITY OF SHEAR CONNECTORS
DEFORMATION CAPACITY AND DUCTILITY OF SHEAR CONNECTORS
AbstractDeformation capacity and slip range (eventually called “ductility”) of shear connectors are key parameters for the design of shear connectors in composite beams, especially...
Withdrawal Capacity of Joints Constructed with 9.5-mm and 15.9-mm Through-Bolts and Diameter Nominal 15-mm and 25-mm Pipe-Nut Connectors
Withdrawal Capacity of Joints Constructed with 9.5-mm and 15.9-mm Through-Bolts and Diameter Nominal 15-mm and 25-mm Pipe-Nut Connectors
Tests were conducted to determine the withdrawal capacities of 10-mm (nominal ⅜-in.) and 15.9-mm (nominal ⅝-in.) through-bolts with Diameter Nominal (DN) 15-mm (nominal ½-in.) and ...
EXPERIMENTAL INVESTIGATION ON THE SHEAR RESISTANCE OF I-SHAPED PERFORATED CONNECTORS IN COMPOSITE BEAMS
EXPERIMENTAL INVESTIGATION ON THE SHEAR RESISTANCE OF I-SHAPED PERFORATED CONNECTORS IN COMPOSITE BEAMS
Introduction: Steel-concrete composite girders have been widely used in bridges, with the stability of the interface being crucial. Shear connectors and reinforced concrete slabs p...
Tensile Performance of Perforated IPE Connectors within Composite Beams
Tensile Performance of Perforated IPE Connectors within Composite Beams
This paper examines the performance of IPE perforated shear connectors, emphasizing their role in maintaining the structural integrity of composite beams. It focuses on inspecting ...
A New Mechanical Pile Connector Speeds Offshore Contruction Projects
A New Mechanical Pile Connector Speeds Offshore Contruction Projects
Abstract
During the past year, a new mechanical pile connector has been introduced to the offshore construction industry. This connector has been the culmination ...

