AbstractObjectivesTo compare crestal bone modeling at three bone level design implants; Astra Tech Osseospeed™ Implant (AOI), Straumann® Bone Level Implant (SBLI) and NobelReplace™ Tapered Groovy Implant (NBTI).Materials and methodsIn 12 minipigs one implant of each design was placed on each side of the mandible with submerged healing. The implant platform was placed at the level of the crest (Group 0), and 1 mm above the crest (Group + 1 mm). In addition, one Straumann® Tissue Level Implant STLI was placed as a control on each side of the mandible. At 4 weeks, six animals were sacrificed. In the remaining six animals healing abutments were connected until 12 weeks. Clinical, radiographic, and histologic analyses were made. ANOVA and Mann–Whitney U‐tests were used to evaluate differences in bone levels between implant designs.ResultsAt 4 weeks there was no statistically significant difference in bone changes between implant designs. At 12 weeks implants in Group + 1 mm had minimal bone changes with no differences between implant designs. In Group 0, the AOI and SBLI preserved more crestal bone than NBTI (P < 0.01). Mean distance from the implant platform to the buccal bone was −0.1 ± 0.2 mm for AOI, −0.3 ± 0.3 mm for SBLI, and −1.0 ± 0.3 mm for NBTI. Mean radiographic bone levels from the implant platform were −0.1 ± 0.4 mm for AOI, 0.0 ± 0.3 mm for SBLI and −0.9 ± 0.8 mm for NBTI.ConclusionGreater bone preservation was observed for the AOI and SBLI compared with the NBTI.
Title: Preservation of crestal bone by implant design. A comparative study in minipigs
Description:
AbstractObjectivesTo compare crestal bone modeling at three bone level design implants; Astra Tech Osseospeed™ Implant (AOI), Straumann® Bone Level Implant (SBLI) and NobelReplace™ Tapered Groovy Implant (NBTI).
Materials and methodsIn 12 minipigs one implant of each design was placed on each side of the mandible with submerged healing.
The implant platform was placed at the level of the crest (Group 0), and 1 mm above the crest (Group + 1 mm).
In addition, one Straumann® Tissue Level Implant STLI was placed as a control on each side of the mandible.
At 4 weeks, six animals were sacrificed.
In the remaining six animals healing abutments were connected until 12 weeks.
Clinical, radiographic, and histologic analyses were made.
ANOVA and Mann–Whitney U‐tests were used to evaluate differences in bone levels between implant designs.
ResultsAt 4 weeks there was no statistically significant difference in bone changes between implant designs.
At 12 weeks implants in Group + 1 mm had minimal bone changes with no differences between implant designs.
In Group 0, the AOI and SBLI preserved more crestal bone than NBTI (P < 0.
01).
Mean distance from the implant platform to the buccal bone was −0.
1 ± 0.
2 mm for AOI, −0.
3 ± 0.
3 mm for SBLI, and −1.
0 ± 0.
3 mm for NBTI.
Mean radiographic bone levels from the implant platform were −0.
1 ± 0.
4 mm for AOI, 0.
0 ± 0.
3 mm for SBLI and −0.
9 ± 0.
8 mm for NBTI.
ConclusionGreater bone preservation was observed for the AOI and SBLI compared with the NBTI.
Related Results
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Objectives: Bone morphogenetic proteins (BMPs) belong to the transforming growth factor superfamily that were first discovered by Marshall Urist. There are 14 BMPs identified to da...
Stress and Strain Analysis of the Bone-Implant Interface: A Comparison of Fiber-Reinforced Composite and Titanium Implants Utilizing 3-Dimensional Finite Element Study
Stress and Strain Analysis of the Bone-Implant Interface: A Comparison of Fiber-Reinforced Composite and Titanium Implants Utilizing 3-Dimensional Finite Element Study
This study analyzed stress and strain mediated by 2 different implant materials, titanium (Ti) and experimental fiber-reinforced composite (FRC), on the implant and on the bone tis...
Dental Implants’ Primary and Secondary Stability Assessment according to Implant Macro-Design, Length and Width, Location, and Bone Quality.
Dental Implants’ Primary and Secondary Stability Assessment according to Implant Macro-Design, Length and Width, Location, and Bone Quality.
Some evidence supports the influence of the implant macro-design and primary stability. Additionally, tactile perception can be used to assess implant stability when placing the im...
Comparing the Hydrodynamic Piezoelectric Technique with Osseodensification for the Assessment of Internal Sinus Iifting: (a Randomized Clinical Trial)
Comparing the Hydrodynamic Piezoelectric Technique with Osseodensification for the Assessment of Internal Sinus Iifting: (a Randomized Clinical Trial)
Abstract
Objectives: The purpose of this study was to compare outcomes of internal sinus lifting using osseodensification and piezoelectric surgery approaches on dental imp...
Crown-to-implant ratio of short locking-taper implants placed in posterior areas of the maxilla: a retrospective study 2 years after loading
Crown-to-implant ratio of short locking-taper implants placed in posterior areas of the maxilla: a retrospective study 2 years after loading
Introduction: The purpose was to study any relationship between crown-to-implant ratio and peri-implant bone loss of short, plateau-design, locking taper implants in posterior maxi...
Evaluation of hybrid implant in posterior edentulous maxilla with inadequate bone
Evaluation of hybrid implant in posterior edentulous maxilla with inadequate bone
Aim of this study is to investigate.Hybrid implant has got satisfactory results in our previous study in various edentulous areas with inadequate bone for endosseous implant placem...