Javascript must be enabled to continue!
Intraoperative Measurement and Biomechanical Modeling of the Flexor Carpi Ulnaris-to-Extensor Carpi Radialis Longus Tendon Transfer
View through CrossRef
Sarcomere length was measured intraoperatively in five patients undergoing tendon transfer of the flexor carpi ulnaris (FCU) to the extensor carpi radialis longus (ECRL) for radial nerve palsy. All measurements were made with the elbow in 20 deg of flexion. Prior to tendon transfer, FCU sarcomere length ranged from 2.84 ±. 12 μm (mean ± SEM) with the wrist flexed to 4.16 ± .15 μm with the wrist extended. After transfer into the ECRL tendon, sarcomere length ranged from 4.82 ± .11 μm with the wrist flexed (the new longest position of the FCU) to 3.20 ± .09 μm with the wrist extended, resulting in a shift in the sarcomere length operating range to significantly longer sarcomere lengths (p < 0.001). At these longer sarcomere lengths, the FCU muscle was predicted to develop high active tension only when the wrist was highly extended. A biomechanical model of this tendon transfer was generated using normative values obtained from previous studies of muscle architectural properties, tendon compliance, and joint moment arms. Predicted sarcomere lengths pre- and post-tendon transfer agreed well with intraoperative experimental measurements. The theoretical wrist extension moment-wrist joint angle relationship was also calculated for a variety of values of FCU muscle length. These different lengths represented the different conditions under which the FCU could be sutured into the ECRL tendon. Variation in FCU muscle length over the range 200 mm to 260 mm resulted in large changes in absolute peak moment produced as well as the angular dependence of peak moment. This was due to the change in the region of FCU operation on its sarcomere length-tension curve relative to the magnitude of the ECRL moment arm. These data demonstrate the sensitivity of a short-fibered muscle such as the FCU to affect the functional outcome of surgery. In addition, we demonstrated that intraoperative sarcomere length measurements, combined with biomechanical modeling provide the surgeon with a powerful method for predicting the functional effect of tendon transfer surgery.
Title: Intraoperative Measurement and Biomechanical Modeling of the Flexor Carpi Ulnaris-to-Extensor Carpi Radialis Longus Tendon Transfer
Description:
Sarcomere length was measured intraoperatively in five patients undergoing tendon transfer of the flexor carpi ulnaris (FCU) to the extensor carpi radialis longus (ECRL) for radial nerve palsy.
All measurements were made with the elbow in 20 deg of flexion.
Prior to tendon transfer, FCU sarcomere length ranged from 2.
84 ±.
12 μm (mean ± SEM) with the wrist flexed to 4.
16 ± .
15 μm with the wrist extended.
After transfer into the ECRL tendon, sarcomere length ranged from 4.
82 ± .
11 μm with the wrist flexed (the new longest position of the FCU) to 3.
20 ± .
09 μm with the wrist extended, resulting in a shift in the sarcomere length operating range to significantly longer sarcomere lengths (p < 0.
001).
At these longer sarcomere lengths, the FCU muscle was predicted to develop high active tension only when the wrist was highly extended.
A biomechanical model of this tendon transfer was generated using normative values obtained from previous studies of muscle architectural properties, tendon compliance, and joint moment arms.
Predicted sarcomere lengths pre- and post-tendon transfer agreed well with intraoperative experimental measurements.
The theoretical wrist extension moment-wrist joint angle relationship was also calculated for a variety of values of FCU muscle length.
These different lengths represented the different conditions under which the FCU could be sutured into the ECRL tendon.
Variation in FCU muscle length over the range 200 mm to 260 mm resulted in large changes in absolute peak moment produced as well as the angular dependence of peak moment.
This was due to the change in the region of FCU operation on its sarcomere length-tension curve relative to the magnitude of the ECRL moment arm.
These data demonstrate the sensitivity of a short-fibered muscle such as the FCU to affect the functional outcome of surgery.
In addition, we demonstrated that intraoperative sarcomere length measurements, combined with biomechanical modeling provide the surgeon with a powerful method for predicting the functional effect of tendon transfer surgery.
Related Results
Prevalensi Absensi Palmaris Longus Tendon Suku Lampung Pada Civitas Akademika Universitas Malahayati Bandar Lampung
Prevalensi Absensi Palmaris Longus Tendon Suku Lampung Pada Civitas Akademika Universitas Malahayati Bandar Lampung
ABSTRAK Latar Belakang : Perkembangan tendon Palmaris Longus sudah lengkap saat dilahirkan. Tendon Palmaris Longus tidak akan berkembang lagi sesudah itu. tendon Palmaris Longus se...
The Effectiveness and Comparison of the Outcome of Tibialis Posterior Tendon Transfer to Tibialis Anterior & Peroneus Longus Versus Extensor Hallucis Longus & Extensor Digitorum Longus for Management of Footdrop
The Effectiveness and Comparison of the Outcome of Tibialis Posterior Tendon Transfer to Tibialis Anterior & Peroneus Longus Versus Extensor Hallucis Longus & Extensor Digitorum Longus for Management of Footdrop
Background: Common Peroneal Nerve (CPN) palsy resulting footdrop has been reported as the most frequent lower extremity palsy. Footdrop is a disabling condition and the result of n...
TGF-β3 Regulates Adhesion Formation Through the JNK/c-Jun Pathway During Flexor Tendon Healing
TGF-β3 Regulates Adhesion Formation Through the JNK/c-Jun Pathway During Flexor Tendon Healing
Abstract
Background: The injured flexor tendon has poor healing ability, 15 which is easy to cause tendon adhesion. It can affect the recovery of tendon function, which is ...
Spontaneous rupture of extensor pollicis longus after distal radius fracture: a case report
Spontaneous rupture of extensor pollicis longus after distal radius fracture: a case report
Extensor pollicis longus tendon rupture, rare and linked to trauma or arthritis, is prevalent post-distal radius fractures. Mechanisms include friction and vascular issues. Manifes...
An Indigenous Study on The Palmaris Longus Muscle Anatomical Variations
An Indigenous Study on The Palmaris Longus Muscle Anatomical Variations
Introduction: The Palmaris longus muscle is one of the superficial flexor muscles of the forearm that flexes the hand on the wrist and makes the palmar aponeurosis tense for grippi...
Anatomía arterial de los colgajos musculares de extensor carpi radialis longus y extensor carpi radialis brevis para su uso en transferencia muscular funcional libre
Anatomía arterial de los colgajos musculares de extensor carpi radialis longus y extensor carpi radialis brevis para su uso en transferencia muscular funcional libre
intro_obj: El objetivo de este trabajo es documentar el aporte arterial y el patrón vascular intramuscular de los músculos Extensor Carpi Radialis Longus (ECRL) y Extensor Carpi Ra...
Anatomical and biomechanical characteristics of fibularis longus tendon used for cruciate ligaments reconstruction
Anatomical and biomechanical characteristics of fibularis longus tendon used for cruciate ligaments reconstruction
Abstract
Introduction: Arthroscopic reconstruction of the cruciate ligament of the knee becomes routine with modern techniques and special instruments. However, the source of mater...
Sonographic Evidence for the Absence of Abductor Pollicis Longus, Extensor Pollicis Longus, and Brevis
Sonographic Evidence for the Absence of Abductor Pollicis Longus, Extensor Pollicis Longus, and Brevis
Complete absence or variations of extensor pollicis brevis and abductor pollicis longus; absence of the extrinsic extensors, abductor pollicis longus, thenar muscles along with con...

