Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A 0.8-Volt 29.52-μW Current Mirror-Based OTA Design for Biomedical Applications

View through CrossRef
An operational trans-conductance amplifier (OTA) is a fundamental component of electronic appliances. This paper introduces a novel design of OTA for minimal power, low voltage applications. The proposed OTA comprises an ultra low power current mirror design with enhanced bandwidth. The proposed OTA circuit is operated at 0.8[Formula: see text]V, contributing input noise of 26.33[Formula: see text]nV/(Hz)[Formula: see text] with a power of [Formula: see text]W. The additional parameters of new OTA are DC gain (87.32[Formula: see text]dB), common mode rejection ratio (145.47[Formula: see text]dB), gain bandwidth (4.73[Formula: see text]MHz), phase margin (36.56[Formula: see text]). These figures are significantly improved as compared to conventional OTAs. Analog-to-digital convertor (ADC) is also designed as an application of the proposed OTA. The improvements offered by ADC in terms of power and bandwidth are also compared with state of the art.
Title: A 0.8-Volt 29.52-μW Current Mirror-Based OTA Design for Biomedical Applications
Description:
An operational trans-conductance amplifier (OTA) is a fundamental component of electronic appliances.
This paper introduces a novel design of OTA for minimal power, low voltage applications.
The proposed OTA comprises an ultra low power current mirror design with enhanced bandwidth.
The proposed OTA circuit is operated at 0.
8[Formula: see text]V, contributing input noise of 26.
33[Formula: see text]nV/(Hz)[Formula: see text] with a power of [Formula: see text]W.
The additional parameters of new OTA are DC gain (87.
32[Formula: see text]dB), common mode rejection ratio (145.
47[Formula: see text]dB), gain bandwidth (4.
73[Formula: see text]MHz), phase margin (36.
56[Formula: see text]).
These figures are significantly improved as compared to conventional OTAs.
Analog-to-digital convertor (ADC) is also designed as an application of the proposed OTA.
The improvements offered by ADC in terms of power and bandwidth are also compared with state of the art.

Related Results

Revisiting the OTA-OFC: a systematic review of open fracture classification studies since 2010
Revisiting the OTA-OFC: a systematic review of open fracture classification studies since 2010
Abstract Introduction: Management of open extremity fractures presents significant challenges due to infection risks and healing complications. T...
Ochratoxin A in Human Milk From the MIREC Study
Ochratoxin A in Human Milk From the MIREC Study
Abstract Background Ochratoxin A (OTA) is a mycotoxin produced by multiple fungal species and is found in a variety of foods. In...
Design
Design
Conventional definitions of design rarely capture its reach into our everyday lives. The Design Council, for example, estimates that more than 2.5 million people use design-related...
OTA-Grapes: A Mechanistic Model to Predict Ochratoxin A Risk in Grapes, a Step beyond the Systems Approach
OTA-Grapes: A Mechanistic Model to Predict Ochratoxin A Risk in Grapes, a Step beyond the Systems Approach
Ochratoxin A (OTA) is a fungal metabolite dangerous for human and animal health due to its nephrotoxic, immunotoxic, mutagenic, teratogenic and carcinogenic effects, classified by ...
Ochratoxin A in Rice Marketed in United Arab Emirates. (c2022)
Ochratoxin A in Rice Marketed in United Arab Emirates. (c2022)
Rice is one of the most consumed staple foods around the world. A. Circumdati, A. Nigri, P. verrucosum, and P. nordicum can contaminate rice in subtropical and tropical hot and hum...
Pengaruh Rangkaian Seri Dan Paralel Terhadap Tegangan Pada Piezoelektrik
Pengaruh Rangkaian Seri Dan Paralel Terhadap Tegangan Pada Piezoelektrik
Abstrak Background: Piezoelektrik didefinisikan sebagai kemampuan yang dimiliki oleh kristal pada bahan-bahan tertentu yang menghasilkan energi listrik jika diberi beban. Pen...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Alkali-based pre-treatment may prevent ochratoxin A in grapes
Alkali-based pre-treatment may prevent ochratoxin A in grapes
In traditional raisin production process in Turkey, one of the major raisin producers in the world, grapes undergo an alkali treatment prior to drying. This procedure involves dipp...

Back to Top