Comparing image quality of five breast tomosynthesis systems based on radiologists’ reviews of phantom data

View through CrossRef
Background Previous studies have shown differences in technical image quality between digital breast tomosynthesis (DBT) systems. However, quantitative image quality measurements may not necessarily fully reflect the clinical performance of DBT. Purpose To study the subjective image quality of five DBT systems manufactured by Fujifilm, GE, Hologic, Planmed, and Siemens using phantom images. Material and Methods A TOR MAM test object with polymethyl methacrylate plates was imaged on five DBT systems from different vendors. Three DBT acquisitions were performed at mean glandular doses of 1.0 mGy, 2.0 mGy, and 3.5 mGy while maintaining a constant phantom set-up. Eight DBT acquisitions with different test plate positions and phantom set-up thicknesses were performed at clinically applied dose levels. Additionally, three conventional two-dimensional mammogram images were acquired with different phantom thicknesses. Six radiologists ranked the systems based on the visibilities of the targets seen in the phantom images. Results In the DBT acquisitions performed at comparable dose levels, one system differed significantly from all other systems in microcalcification scores. When using site-specific DBT protocols, significant differences were found between the devices for microcalcification, filament, and low-contrast targets. A strong correlation was observed between the reviewer scores and radiation doses in DBT acquisitions, whereas no such correlation was observed in the 2D acquisitions. Conclusion In DBT acquisitions, dose level was found to be a major factor explaining image quality differences between the systems, regardless of other acquisition parameters. Most DBT systems performed equally well at similar dose levels.
Title: Comparing image quality of five breast tomosynthesis systems based on radiologists’ reviews of phantom data
Description:
Background Previous studies have shown differences in technical image quality between digital breast tomosynthesis (DBT) systems.
However, quantitative image quality measurements may not necessarily fully reflect the clinical performance of DBT.
Purpose To study the subjective image quality of five DBT systems manufactured by Fujifilm, GE, Hologic, Planmed, and Siemens using phantom images.
Material and Methods A TOR MAM test object with polymethyl methacrylate plates was imaged on five DBT systems from different vendors.
Three DBT acquisitions were performed at mean glandular doses of 1.
0 mGy, 2.
0 mGy, and 3.
5 mGy while maintaining a constant phantom set-up.
Eight DBT acquisitions with different test plate positions and phantom set-up thicknesses were performed at clinically applied dose levels.
Additionally, three conventional two-dimensional mammogram images were acquired with different phantom thicknesses.
Six radiologists ranked the systems based on the visibilities of the targets seen in the phantom images.
Results In the DBT acquisitions performed at comparable dose levels, one system differed significantly from all other systems in microcalcification scores.
When using site-specific DBT protocols, significant differences were found between the devices for microcalcification, filament, and low-contrast targets.
A strong correlation was observed between the reviewer scores and radiation doses in DBT acquisitions, whereas no such correlation was observed in the 2D acquisitions.
Conclusion In DBT acquisitions, dose level was found to be a major factor explaining image quality differences between the systems, regardless of other acquisition parameters.
Most DBT systems performed equally well at similar dose levels.

Related Results

Desmoid-Type Fibromatosis of The Breast: A Case Series
Desmoid-Type Fibromatosis of The Breast: A Case Series
Abstract IntroductionDesmoid-type fibromatosis (DTF), also called aggressive fibromatosis, is a rare, benign, locally aggressive condition. Mammary DTF originates from fibroblasts ...
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract Introduction Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Low-dose, X-ray-based Imaging of Lung Function
Low-dose, X-ray-based Imaging of Lung Function
<p>Chronic obstructive pulmonary disease (COPD) is characterized by chronic airflow limitation resulting from emphysema and small airway disease. Functional lung imaging of C...
PO-285 A review of effects of exercise on the quality of life in breast cancer survivors
PO-285 A review of effects of exercise on the quality of life in breast cancer survivors
Objective Breast cancer is one of the most common malignant tumors in women.The number of women diagnosed with breast cancer each year is also increasing.It is also the leading cau...
SU‐FF‐I‐113: Anatomical Power Spectrum and Detectability: An Analytical and Experimental Basis
SU‐FF‐I‐113: Anatomical Power Spectrum and Detectability: An Analytical and Experimental Basis
Purpose: Superposition of anatomical clutter in medical images is known to degrade detectability of underlying structures. This paper investigates background power spectrum (PS) in...
Spanish Breast Cancer Research Group (GEICAM)
Spanish Breast Cancer Research Group (GEICAM)
This section provides current contact details and a summary of recent or ongoing clinical trials being coordinated by Spanish Breast Cancer Research Group (GEICAM). Clinical trials...

Back to Top