Comparing image quality of five breast tomosynthesis systems based on radiologists’ reviews of phantom data

View through CrossRef
Background Previous studies have shown differences in technical image quality between digital breast tomosynthesis (DBT) systems. However, quantitative image quality measurements may not necessarily fully reflect the clinical performance of DBT. Purpose To study the subjective image quality of five DBT systems manufactured by Fujifilm, GE, Hologic, Planmed, and Siemens using phantom images. Material and Methods A TOR MAM test object with polymethyl methacrylate plates was imaged on five DBT systems from different vendors. Three DBT acquisitions were performed at mean glandular doses of 1.0 mGy, 2.0 mGy, and 3.5 mGy while maintaining a constant phantom set-up. Eight DBT acquisitions with different test plate positions and phantom set-up thicknesses were performed at clinically applied dose levels. Additionally, three conventional two-dimensional mammogram images were acquired with different phantom thicknesses. Six radiologists ranked the systems based on the visibilities of the targets seen in the phantom images. Results In the DBT acquisitions performed at comparable dose levels, one system differed significantly from all other systems in microcalcification scores. When using site-specific DBT protocols, significant differences were found between the devices for microcalcification, filament, and low-contrast targets. A strong correlation was observed between the reviewer scores and radiation doses in DBT acquisitions, whereas no such correlation was observed in the 2D acquisitions. Conclusion In DBT acquisitions, dose level was found to be a major factor explaining image quality differences between the systems, regardless of other acquisition parameters. Most DBT systems performed equally well at similar dose levels.
Title: Comparing image quality of five breast tomosynthesis systems based on radiologists’ reviews of phantom data
Description:
Background Previous studies have shown differences in technical image quality between digital breast tomosynthesis (DBT) systems.
However, quantitative image quality measurements may not necessarily fully reflect the clinical performance of DBT.
Purpose To study the subjective image quality of five DBT systems manufactured by Fujifilm, GE, Hologic, Planmed, and Siemens using phantom images.
Material and Methods A TOR MAM test object with polymethyl methacrylate plates was imaged on five DBT systems from different vendors.
Three DBT acquisitions were performed at mean glandular doses of 1.
0 mGy, 2.
0 mGy, and 3.
5 mGy while maintaining a constant phantom set-up.
Eight DBT acquisitions with different test plate positions and phantom set-up thicknesses were performed at clinically applied dose levels.
Additionally, three conventional two-dimensional mammogram images were acquired with different phantom thicknesses.
Six radiologists ranked the systems based on the visibilities of the targets seen in the phantom images.
Results In the DBT acquisitions performed at comparable dose levels, one system differed significantly from all other systems in microcalcification scores.
When using site-specific DBT protocols, significant differences were found between the devices for microcalcification, filament, and low-contrast targets.
A strong correlation was observed between the reviewer scores and radiation doses in DBT acquisitions, whereas no such correlation was observed in the 2D acquisitions.
Conclusion In DBT acquisitions, dose level was found to be a major factor explaining image quality differences between the systems, regardless of other acquisition parameters.
Most DBT systems performed equally well at similar dose levels.

Related Results

Desmoid-Type Fibromatosis of The Breast: A Case Series
Desmoid-Type Fibromatosis of The Breast: A Case Series
Abstract IntroductionDesmoid-type fibromatosis (DTF), also called aggressive fibromatosis, is a rare, benign, locally aggressive condition. Mammary DTF originates from fibroblasts ...
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract Introduction Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Body image and perception among adults with and without phantom limb pain
Body image and perception among adults with and without phantom limb pain
AbstractBackgroundFollowing lower‐limb amputation, phantom limb pain (i.e., pain perceived as coming from the amputated portion of the limb) is common. Phantom limb pain may be ass...
AI and Incidental Findings
AI and Incidental Findings
Photo by Accuray on Unsplash INTRODUCTION Delayed and missed follow-up on incidental findings threatens patient health and is a major financial risk for healthcare systems. The hea...
Staging of breast cancer and the advanced applications of digital mammogram: what the physician needs to know?
Staging of breast cancer and the advanced applications of digital mammogram: what the physician needs to know?
Objective: To study the role of advanced applications of digital mammogram, whether contrast-enhanced spectral mammography (CESM) or digital breast tomosynthesis ...
Low-dose, X-ray-based Imaging of Lung Function
Low-dose, X-ray-based Imaging of Lung Function
<p>Chronic obstructive pulmonary disease (COPD) is characterized by chronic airflow limitation resulting from emphysema and small airway disease. Functional lung imaging of C...
Low-dose, X-ray-based Imaging of Lung Function
Low-dose, X-ray-based Imaging of Lung Function
<p>Chronic obstructive pulmonary disease (COPD) is characterized by chronic airflow limitation resulting from emphysema and small airway disease. Functional lung imaging of C...

Back to Top