A Recapping System for Automatic, Semiautomatic, and Manual Use

View through CrossRef
Abstract Context. —Closed sample tubes are needed for stored as well as in-process samples because evaporation significantly changes analyte concentrations. In modern laboratories, it is essential that the procedures for ordering tests on stored serum samples be simple and time-efficient. Therefore, recapping and reopening of tubes should be readily possible in laboratories to save resources and time. Objective. —To evaluate the recapping system MagCap, in comparison to established snap caps and unsealed tubes. Design. —Specific balls, with an iron core, fit tightly by their specific weight into openings of primary and secondary tubes as well as microtiter plates. Recapping of the tubes can be performed individually by a single dispenser or rackwise by a multidispenser. Balls can be removed individually by a pencillike magnet or rackwise. Balls can be reused after cleaning in a glassware washer or used as disposables. Results. —Balls seal the sample tubes as effectively as snap caps and decrease evaporation significantly in comparison to unsealed tubes. Evaporation effects of up to 13% were detected in unsealed tubes (0.5 mL) within 24 hours, whereas resealing of the tubes diminished the concentration effect to less than 1%. Open samples (0.5 mL) showed a concentration effect in the refrigerator within 7 days of up to 25%. The evaporation effect of the sealed tubes was less than 3%. Multiple reopenening and recapping procedures are easily possible using magnetic forces. Conclusions. —The MagCap recapping system seals primary and secondary containers securely and cost-effectively with the ball cap and thus facilitates a necessary advance in sample quality.
Title: A Recapping System for Automatic, Semiautomatic, and Manual Use
Description:
Abstract Context.
—Closed sample tubes are needed for stored as well as in-process samples because evaporation significantly changes analyte concentrations.
In modern laboratories, it is essential that the procedures for ordering tests on stored serum samples be simple and time-efficient.
Therefore, recapping and reopening of tubes should be readily possible in laboratories to save resources and time.
Objective.
—To evaluate the recapping system MagCap, in comparison to established snap caps and unsealed tubes.
Design.
—Specific balls, with an iron core, fit tightly by their specific weight into openings of primary and secondary tubes as well as microtiter plates.
Recapping of the tubes can be performed individually by a single dispenser or rackwise by a multidispenser.
Balls can be removed individually by a pencillike magnet or rackwise.
Balls can be reused after cleaning in a glassware washer or used as disposables.
Results.
—Balls seal the sample tubes as effectively as snap caps and decrease evaporation significantly in comparison to unsealed tubes.
Evaporation effects of up to 13% were detected in unsealed tubes (0.
5 mL) within 24 hours, whereas resealing of the tubes diminished the concentration effect to less than 1%.
Open samples (0.
5 mL) showed a concentration effect in the refrigerator within 7 days of up to 25%.
The evaporation effect of the sealed tubes was less than 3%.
Multiple reopenening and recapping procedures are easily possible using magnetic forces.
Conclusions.
—The MagCap recapping system seals primary and secondary containers securely and cost-effectively with the ball cap and thus facilitates a necessary advance in sample quality.

Related Results

Incremental prognostic value of fully automatic LVEF measured at stress using machine learning
Incremental prognostic value of fully automatic LVEF measured at stress using machine learning
Abstract Background Cardiovascular magnetic resonance (CMR) is the gold standard to measure left ventricular ejection fraction (...
Investigation on Mechanical Properties of X80 Pipeline Girth Weld Welded by Semi-Automatic and Automatic Welding
Investigation on Mechanical Properties of X80 Pipeline Girth Weld Welded by Semi-Automatic and Automatic Welding
Abstract The traditional manual welding in pipeline construction is being gradually replaced by semi-automatic and automatic welding in China. Semi-automatic welding...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Semiautomatic inverse filtering of vowels with differing degrees of nasality
Semiautomatic inverse filtering of vowels with differing degrees of nasality
Most approaches to inverse filtering are either manual or automatic. Manual methods, while providing high-quality fine-grained analysis, require user expertise and manpower to anal...
Closed-Loop Oxygen Control
Closed-Loop Oxygen Control
<p>Guidelines recommend that oxygen should be titrated to achieve a target oxygen saturation (SpO2 ) range in acutely unwell patients, a concept colloquially known as “swimmi...
Converting Malfunctioned Fully Automatic (Electro-Mechanical Driven) to Semiautomatic Washing Machine
Converting Malfunctioned Fully Automatic (Electro-Mechanical Driven) to Semiautomatic Washing Machine
This study converted a damaged fully automatic washing machine into a semi -automatic washing machine. Conversion of the machine was done due to unavailability of its electronic sp...
Rancang Bangun Pembuat Layout PCB Otomatis Berbasis Android
Rancang Bangun Pembuat Layout PCB Otomatis Berbasis Android
ABSTRACT The purpose of this research is to produce an Android-based automatic PCB layout path maker tool. This tool can automatically create a PCB layout path without etchin...

Back to Top