Javascript must be enabled to continue!
Role of Distal Femur Anatomical Plate in Fracture of Distal Femur
View through CrossRef
Introduction: Distal femur fractures are mostly caused due to vehicular injuries in the middle-aged population. Operative treatment has been preferred with open reduction and internal fixation in these fractures. Due to the availability of anatomical locking compression plates (LCPs), better results and improved functional outcomes have been observed. This study aims to observe the surgical outcome of distal femur fractures operated with an anatomical LCP.
Materials and Methods: A prospective study was carried upon 48 patients with 40 male and 8 female patients having fractures of the distal femur. The mean age of presentation was 40.6 years. Thirty of them had vehicular injuries and 18 had a history of fall. Open fractures were seen in 22 patients and associated ipsilateral limb injuries were seen in 16 and contralateral limb injuries were seen in 8 patients. The patients were treated with anatomical LCP. The lateral approach was used in all cases for my study.
Results: The mean follow-up in the present study was 6 months. All fractures were united with a mean union period of 18.2 weeks. At final follow-up, fixed flexion deformity was seen in 25% of the patients. There were 16 cases of infection with 2 being a superficial infection treated conservatively and 14 cases having a deep infection treated with debridement and antibiotics. 2 cases of nonunion, 4 cases of malunion and 4 cases of delayed union were observed. 16 cases develop joint stiffness. 16 cases also developed limb shortening and 10 had fixed flexion deformity and 8 had varus deformity. At the time of final follow-up through “SCHATZKER AND LAMBERT SCORING SYSTEM,” satisfactory outcomes were achieved in 50% (20.8%excellent and 29.2% good) of the patients.
Conclusion: Distal femur fracture treated with anatomical LCP needs careful anatomical reduction, rigid fixation and early knee mobilisation and weight bearing on signs of healing with an early presentation to the hospital from the time of injury were the essential factors in achieving better outcome for the patient.
Keywords: Distal femur anatomical plate, distal femur fracture, Schatzker and Lambert scoring system.
Indian Orthopaedic Research Group
Title: Role of Distal Femur Anatomical Plate in Fracture of Distal Femur
Description:
Introduction: Distal femur fractures are mostly caused due to vehicular injuries in the middle-aged population.
Operative treatment has been preferred with open reduction and internal fixation in these fractures.
Due to the availability of anatomical locking compression plates (LCPs), better results and improved functional outcomes have been observed.
This study aims to observe the surgical outcome of distal femur fractures operated with an anatomical LCP.
Materials and Methods: A prospective study was carried upon 48 patients with 40 male and 8 female patients having fractures of the distal femur.
The mean age of presentation was 40.
6 years.
Thirty of them had vehicular injuries and 18 had a history of fall.
Open fractures were seen in 22 patients and associated ipsilateral limb injuries were seen in 16 and contralateral limb injuries were seen in 8 patients.
The patients were treated with anatomical LCP.
The lateral approach was used in all cases for my study.
Results: The mean follow-up in the present study was 6 months.
All fractures were united with a mean union period of 18.
2 weeks.
At final follow-up, fixed flexion deformity was seen in 25% of the patients.
There were 16 cases of infection with 2 being a superficial infection treated conservatively and 14 cases having a deep infection treated with debridement and antibiotics.
2 cases of nonunion, 4 cases of malunion and 4 cases of delayed union were observed.
16 cases develop joint stiffness.
16 cases also developed limb shortening and 10 had fixed flexion deformity and 8 had varus deformity.
At the time of final follow-up through “SCHATZKER AND LAMBERT SCORING SYSTEM,” satisfactory outcomes were achieved in 50% (20.
8%excellent and 29.
2% good) of the patients.
Conclusion: Distal femur fracture treated with anatomical LCP needs careful anatomical reduction, rigid fixation and early knee mobilisation and weight bearing on signs of healing with an early presentation to the hospital from the time of injury were the essential factors in achieving better outcome for the patient.
Keywords: Distal femur anatomical plate, distal femur fracture, Schatzker and Lambert scoring system.
Related Results
Cometary Physics Laboratory: spectrophotometric experiments
Cometary Physics Laboratory: spectrophotometric experiments
<p><strong><span dir="ltr" role="presentation">1. Introduction</span></strong&...
Risk factors, classification, and operative choices of femur fractures at a Tertiary Hospital: first report from Somalia
Risk factors, classification, and operative choices of femur fractures at a Tertiary Hospital: first report from Somalia
AbstractA traumatic femur fracture is a significant cause of morbidity, affecting one to three million individuals annually. The present is the first study investigated the epidemi...
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Abstract
In this paper, a case study in a fractured carbonate reservoir is presented to demonstrate the approach of fracture modeling using fracture intensity vol...
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra...
Quantifying the Sensitivity of Dielectric Dispersion Data to Fracture Properties in Fractured Rocks
Quantifying the Sensitivity of Dielectric Dispersion Data to Fracture Properties in Fractured Rocks
Evaluation of fluid storage and flow capacity of a fractured rock system needs a comprehensive characterization of all the fracture properties. These properties include the fractur...
Reverse distal femoral locking plate for subtrochanter femur fracture
Reverse distal femoral locking plate for subtrochanter femur fracture
In these case series, we used titanium locking compression plate-distal femur (LCP-DF) plate (Synthes) 9–11 hole using less invasive stabilization system or open reduction techniqu...
Connectivity Assessment and Permeability Upscaling of Fracture Network Using Grid Independent Particle Tracking Algorithm
Connectivity Assessment and Permeability Upscaling of Fracture Network Using Grid Independent Particle Tracking Algorithm
Abstract
Discrete Fracture Network (DFN) models are now becoming an industry practice to model fractures in naturally fractured reservoirs. However, incorporating th...
Application of Lightning Breakdown Simulation in Inversion of Induced Fracture Network Morphology in Stimulated Reservoirs
Application of Lightning Breakdown Simulation in Inversion of Induced Fracture Network Morphology in Stimulated Reservoirs
Abstract
Accurately characterizing fracture network morphology is necessary for flow simulation and fracturing evaluation. The complex natural fractures and reservoi...

