Javascript must be enabled to continue!
Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor
View through CrossRef
Setting the speed of infusion drops in a manual manner is by adjusting the clamp on the infusion set, where the nurse must count the number of infusion drops in the chamber at the same time as looking at the time on the watch. This makes the setting is subjective and cannot be shown with numbers. In addition, nurses cannot monitor the infusion rate continuously. Therefore, it is necessary to enhancement the accuracy of giving infusion drops so that they can be objective and can be shown with numbers and monitor continuously. This enhancement in accuracy is done by making a instrument with an optocoupler to detect infusion drops. For processing uses an arduino microcontroller to be the speed and the volume of infusion and detects changes in the rate of infusion drops significantly. And for the display uses a OLED display and a buzzer as an indicator. The results of this instrument, it can be seen that the optocoupler can detect infusion drops in the infusion set properly. This good sensor reading has implications for accurate readings of the infusion drop rate and infusion drop volume. This enhancement in accuracy is not only for the macro drip (20 drops/cc) but also for the micro drip (60 drops/cc). The accuracy of volume readings ranges from 95-99% for the macro drip and 94.5-97% with the micro drip. And for speed accuracy ranges from 92.37-98.46%. Based from the results of this test, enhancement the accuracy of the infusion drip dose administration can be done by making a patient infusion drip dose calculator. This equipment uses an optocoupler sensor, arduino microcontroller, OLED display and buzzer. With the use of this instrument, nurses can be more accurate in regulating the rate of infusion drops given to patients and can monitor it continuously if there is a significant change in infusion rate.
Title: Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor
Description:
Setting the speed of infusion drops in a manual manner is by adjusting the clamp on the infusion set, where the nurse must count the number of infusion drops in the chamber at the same time as looking at the time on the watch.
This makes the setting is subjective and cannot be shown with numbers.
In addition, nurses cannot monitor the infusion rate continuously.
Therefore, it is necessary to enhancement the accuracy of giving infusion drops so that they can be objective and can be shown with numbers and monitor continuously.
This enhancement in accuracy is done by making a instrument with an optocoupler to detect infusion drops.
For processing uses an arduino microcontroller to be the speed and the volume of infusion and detects changes in the rate of infusion drops significantly.
And for the display uses a OLED display and a buzzer as an indicator.
The results of this instrument, it can be seen that the optocoupler can detect infusion drops in the infusion set properly.
This good sensor reading has implications for accurate readings of the infusion drop rate and infusion drop volume.
This enhancement in accuracy is not only for the macro drip (20 drops/cc) but also for the micro drip (60 drops/cc).
The accuracy of volume readings ranges from 95-99% for the macro drip and 94.
5-97% with the micro drip.
And for speed accuracy ranges from 92.
37-98.
46%.
Based from the results of this test, enhancement the accuracy of the infusion drip dose administration can be done by making a patient infusion drip dose calculator.
This equipment uses an optocoupler sensor, arduino microcontroller, OLED display and buzzer.
With the use of this instrument, nurses can be more accurate in regulating the rate of infusion drops given to patients and can monitor it continuously if there is a significant change in infusion rate.
Related Results
Research on Underground Drip Irrigation and Soil Redistribution - Take Heshan District of Yiyang City as an Example
Research on Underground Drip Irrigation and Soil Redistribution - Take Heshan District of Yiyang City as an Example
Abstract: The drip flow and the buried depth of drip irrigation zone are not only important parameters of subsurface irrigation design and operation management, but also important ...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Modern approaches to infusion therapy in pediatrics and chemotherapy
Modern approaches to infusion therapy in pediatrics and chemotherapy
Background. Systems for intravenous administration of blood products and drugs are divided into the systems for transfusion (pore diameter – 114-200 μm) and systems for infusion (p...
Risk assessment method for emitter clogging in drip irrigation systems
Risk assessment method for emitter clogging in drip irrigation systems
Abstract
Risk assessment of drip irrigation system emitter clogging is critical for the system's safe operation. In this paper, the emitter clogging risk and the calculatio...
Variations and Significance of Mg/Sr and 87Sr/86Sr of drip water and active speleothem in Furong Cave, Southwest China
Variations and Significance of Mg/Sr and 87Sr/86Sr of drip water and active speleothem in Furong Cave, Southwest China
<p>Cave monitoring is an important method to investigate the deposition mechanism and factor influencing the trace elements in drip water and speleothemsThe Mg and Sr...
A method for automated drip irrigation and fertigation of crops
A method for automated drip irrigation and fertigation of crops
Abstract
In the agricultural field, continuously monitoring and protecting is an important task for the farmers because it enhances the crop growth. Continuous crop growth ...
Pembuatan Alat Monitoring Infus Berbasis NodeMCU ESP8266
Pembuatan Alat Monitoring Infus Berbasis NodeMCU ESP8266
The problem of late replacement of infusion mattresses for patients in a medical institution is still common today. It still helps him closely with the nurses' negligence in monito...

