Javascript must be enabled to continue!
Active reactions of the rabbit ear artery to distension.
View through CrossRef
Changes in the external diameter of active arteries, excised from the rabbit ear, were recorded following jumps in pressure within the arteries. The arteries were either spontaneously active or were constricted with noradrenaline. Active arteries dilated when the transmural pressure was jumped from 60 to 100 mmHg, but the dilatation was largely, sometimes completely, overcome by compensatory constriction within 1‐2 min. Varying the constriction from 15 to 80% of the maximal constriction had no effect on the ability of the arteries to counteract distension. An average of 90 +/‐ 2% of the distension was overcome in 2 min and this was achieved against increases in stress (force/wall cross‐sectional area) on the muscle of not less than 74%. Jumps in pressure rarely enhanced constriction and then only when constriction was slight (less than 15% of maximal). Restoring the transmural pressure to 60 from 100 mmHg produced a transient constriction when the initial constriction was less than 50% of the maximal constriction. The sequence of counteraction of distension and transient constriction on reversing the pressure jump was reproducible for many hours. Increasing constriction of the arteries first decreased and then, at maximal constriction, suppressed all transient changes in diameter. Smaller jumps in pressure produced less dilatation which was more readily prevented by increasing constriction. These results show that the wall of the ear artery possesses a pressure‐sensitive, negative feed‐back mechanism which minimized changes in diameter following jumps in pressure.
Title: Active reactions of the rabbit ear artery to distension.
Description:
Changes in the external diameter of active arteries, excised from the rabbit ear, were recorded following jumps in pressure within the arteries.
The arteries were either spontaneously active or were constricted with noradrenaline.
Active arteries dilated when the transmural pressure was jumped from 60 to 100 mmHg, but the dilatation was largely, sometimes completely, overcome by compensatory constriction within 1‐2 min.
Varying the constriction from 15 to 80% of the maximal constriction had no effect on the ability of the arteries to counteract distension.
An average of 90 +/‐ 2% of the distension was overcome in 2 min and this was achieved against increases in stress (force/wall cross‐sectional area) on the muscle of not less than 74%.
Jumps in pressure rarely enhanced constriction and then only when constriction was slight (less than 15% of maximal).
Restoring the transmural pressure to 60 from 100 mmHg produced a transient constriction when the initial constriction was less than 50% of the maximal constriction.
The sequence of counteraction of distension and transient constriction on reversing the pressure jump was reproducible for many hours.
Increasing constriction of the arteries first decreased and then, at maximal constriction, suppressed all transient changes in diameter.
Smaller jumps in pressure produced less dilatation which was more readily prevented by increasing constriction.
These results show that the wall of the ear artery possesses a pressure‐sensitive, negative feed‐back mechanism which minimized changes in diameter following jumps in pressure.
Related Results
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Prevention and Control Strategy
Prevention and Control Strategy
Ear diseases are considered as one of the common disorders in small animal
practice and the number one cause for veterinary visits among dog owners. Commonly
reported clinical sign...
Distension‐contraction profile of peristalsis in patients with nutcracker esophagus
Distension‐contraction profile of peristalsis in patients with nutcracker esophagus
AbstractIntroductionHigh amplitude peristaltic esophageal contractions, that is, nutcracker esophagus, were originally described in association with “angina‐like pain” of esophagea...
The effect of vaginal distension on the female urinary bladder and urethral sphincters
The effect of vaginal distension on the female urinary bladder and urethral sphincters
AbstractAims.A mention of effect of vaginal distension, as induced by penile thrusting at coitus, on urinary bladder (UB) and urethral sphincters could not be traced in literature....
A rare case report of subscapular artery
A rare case report of subscapular artery
Axillary artery is one of the most important arteries of the upper limb, which is a continua- tion of the subclavian artery. It begins at the lateral border of the first rib and en...
Asymmetric Domino Reactions Based on the Use of Chiral Metal Catalysts
Asymmetric Domino Reactions Based on the Use of Chiral Metal Catalysts
This chapter illustrates how much asymmetric organometallic catalysis has contributed to the development of enantioselective domino and multicomponent reactions. It updates the maj...
Morphology And Morphometry of Human External Ear with Its Significance in Sex Determination and Stature Estimation - An Observational Study
Morphology And Morphometry of Human External Ear with Its Significance in Sex Determination and Stature Estimation - An Observational Study
Background The human ear is unique to individuals, and ear prints, like fingerprints, are discrete enough to distinguish identical twins. Therefore, the external ear could be used ...
Morphology And Morphometry of Human External Ear with Its Significance in Sex Determination and Stature Estimation in South Indian Population - An Observational Study
Morphology And Morphometry of Human External Ear with Its Significance in Sex Determination and Stature Estimation in South Indian Population - An Observational Study
Background The human ear is unique to individuals, and ear prints, like fingerprints, are discrete enough to distinguish identical twins. Therefore, the external ear could be used ...

