Algorithm of reactive power dispatching "per generator" realization on TPP Nikola Tesla A
View through CrossRef
The algorithm of reactive power dispatching "per generator" realization is presented in the paper. Dispatching "per generator" and "per grid" are two modes of reactive power dispatching used by coordinated reactive power and voltage regulator (GRRS). Reactive power dispatching "per generator" ensures equal heating of the generators, while dispatching "per grid" ensures maximal reactive power reserve when generated reactive power either increases, or decreases. Reactive power dispatching "per generator" is more complex for realization because the dispatching criterion may have wider generator's reactive power operation area than the working capability curve. In these cases, the additional limiting of the generator reactive power is necessary, while other generators take over the remaining reactive power, still considering the reactive power dispatching criteria "per generator" and the limits of the remaining generators. Both reactive power dispatching modes are presented in two examples, while operating near and far from the limit area. Eventually, as the verification of the algorithm and its realization, the operating results of GRRS while dispatching "per generator" is active, are presented.
Centre for Evaluation in Education and Science (CEON/CEES)
Title: Algorithm of reactive power dispatching "per generator" realization on TPP Nikola Tesla A
Description:
The algorithm of reactive power dispatching "per generator" realization is presented in the paper.
Dispatching "per generator" and "per grid" are two modes of reactive power dispatching used by coordinated reactive power and voltage regulator (GRRS).
Reactive power dispatching "per generator" ensures equal heating of the generators, while dispatching "per grid" ensures maximal reactive power reserve when generated reactive power either increases, or decreases.
Reactive power dispatching "per generator" is more complex for realization because the dispatching criterion may have wider generator's reactive power operation area than the working capability curve.
In these cases, the additional limiting of the generator reactive power is necessary, while other generators take over the remaining reactive power, still considering the reactive power dispatching criteria "per generator" and the limits of the remaining generators.
Both reactive power dispatching modes are presented in two examples, while operating near and far from the limit area.
Eventually, as the verification of the algorithm and its realization, the operating results of GRRS while dispatching "per generator" is active, are presented.
Related Results
Analysis of the Emission of Pollutants into the Air from Nikola Tesla A and Nikola Tesla B Thermal Power Plants
Analysis of the Emission of Pollutants into the Air from Nikola Tesla A and Nikola Tesla B Thermal Power Plants
The paper presents a temporal analysis of the emission of pollutants into the air on the example of the two largest thermal power plants "Nikola Tesla A" and "Nikola Tesla B". The ...
Thyrotoxic Periodic Paralysis
Thyrotoxic Periodic Paralysis
Abstract
Thyrotoxic Periodic Paralysis (TPP) is an emergency associated with flaccid paralysis in which the paralysis is reversible with prompt potassium replacement...
The correspondence between Nikola Tesla and Orville Wright kept in the scientist's legacy in the Nikola Tesla museum: On the occasion of the 165th anniversary of the birth of Nikola Tesla
The correspondence between Nikola Tesla and Orville Wright kept in the scientist's legacy in the Nikola Tesla museum: On the occasion of the 165th anniversary of the birth of Nikola Tesla
Nikola Tesla and the Wright brothers, Wilbur and Orville, have worked and created in the United States of America in the period comprising the last two decades of the 19th and the ...
An Analysis of Interaction Effects of China–South Korea and China– Australia FTAs and the Expanding TPP
An Analysis of Interaction Effects of China–South Korea and China– Australia FTAs and the Expanding TPP
Abstract
On 5 October 2015, the Trans-Pacific Partnership Agreement (TPP) led by the U.S. was signed. Already, 12 countries1 have joined the agreement, but China ha...
Development, Characterization, in vitro Antidiabetic Activity of Chitosan−tripolyphosphate Nanoparticles Encapsulating
Gmelina arborea
Roxb. and
Spondias pinnata
(L.f) Kurz Aq
Development, Characterization, in vitro Antidiabetic Activity of Chitosan−tripolyphosphate Nanoparticles Encapsulating
Gmelina arborea
Roxb. and
Spondias pinnata
(L.f) Kurz Aq
Abstract
Nanoencapsulation is a promising strategy for the development of novel therapeutic agents from crude aqueous extracts derived from
...
A Case Study of TESLA
A Case Study of TESLA
We hope to observe this company (TESLA) from all angles. In this article, I quoted elements such as the PESTEL model, ESG concept and so on to evaluate Tesla. I hope that readers c...
Effect of triphenylphosphate flame retardant on properties of polybenzoxazines : Research Report
Effect of triphenylphosphate flame retardant on properties of polybenzoxazines : Research Report
To enhance flame retardancy of polybenzoxazines, non-halogenated phosphorus compound has been evaluated for its potential flame retardant. In this research, the resulting flame ret...
Many-Objective Genetic Programming for Job-Shop Scheduling
Many-Objective Genetic Programming for Job-Shop Scheduling
<p>The Job Shop Scheduling (JSS) problem is considered to be a challenging one due to practical requirements such as multiple objectives and the complexity of production flow...