Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Refractive Error Induced by Intraocular Lens Tilt After Intrascleral Intraocular Lens Fixation

View through CrossRef
Abstract Purpose To investigate the spherical shift of Intraocular lens (IOL) tilt after intrascleral fixationMethods We retrospectively reviewed the medical records of patients who underwent flanged intrascleral IOL fixation with transconjunctival 25- or 27-gauge pars plana vitrectomy at the Department of Ophthalmology of Jikei University Hospital with a minimum follow-up duration of three months. Second-generation anterior segment optical coherence tomography (CASIA2; TOMEY) was used to obtain the tilt and decentration of intrasclerally fixated IOL and postoperative anterior chamber depth. We investigated the relationship of the refractive error with these parameters, axial length, and keratometry. In addition to the clinical investigation, we performed optical simulations using the Zemax optical design program for studying the spherical shift of the IOL tilt by means of the through-focus response and change of spherical equivalent power.Results The study involved 72 eyes of 67 patients. The degree of IOL tilt was correlated with the amount of refractive error (Spearman's rank correlation coefficient [CC] = −0.32; P = 0.006). In particular, a tilt angle greater than 10° strongly influenced the refractive error. Postoperative anterior chamber depth also correlated with the refractive error (CC = 0.50; P < 0.001). The refractive error did not correlate with decentration (CC = −0.17; P = 0.15), axial length (CC = −0.08; P = 0.49), and keratometry (CC = −0.06; P =0.64). Optical simulations using the Zemax optical design program also showed a myopic shift exponentially as the tilt becomes greater. Conclusion An IOL tilt greater than 10 ° induces refractive error.
Title: Refractive Error Induced by Intraocular Lens Tilt After Intrascleral Intraocular Lens Fixation
Description:
Abstract Purpose To investigate the spherical shift of Intraocular lens (IOL) tilt after intrascleral fixationMethods We retrospectively reviewed the medical records of patients who underwent flanged intrascleral IOL fixation with transconjunctival 25- or 27-gauge pars plana vitrectomy at the Department of Ophthalmology of Jikei University Hospital with a minimum follow-up duration of three months.
Second-generation anterior segment optical coherence tomography (CASIA2; TOMEY) was used to obtain the tilt and decentration of intrasclerally fixated IOL and postoperative anterior chamber depth.
We investigated the relationship of the refractive error with these parameters, axial length, and keratometry.
In addition to the clinical investigation, we performed optical simulations using the Zemax optical design program for studying the spherical shift of the IOL tilt by means of the through-focus response and change of spherical equivalent power.
Results The study involved 72 eyes of 67 patients.
The degree of IOL tilt was correlated with the amount of refractive error (Spearman's rank correlation coefficient [CC] = −0.
32; P = 0.
006).
In particular, a tilt angle greater than 10° strongly influenced the refractive error.
Postoperative anterior chamber depth also correlated with the refractive error (CC = 0.
50; P < 0.
001).
The refractive error did not correlate with decentration (CC = −0.
17; P = 0.
15), axial length (CC = −0.
08; P = 0.
49), and keratometry (CC = −0.
06; P =0.
64).
Optical simulations using the Zemax optical design program also showed a myopic shift exponentially as the tilt becomes greater.
Conclusion An IOL tilt greater than 10 ° induces refractive error.

Related Results

Optimal Bi-Annual Tilt Angles and Optimal Tilt Transition Timing for Fixed Tilt Arrays in the United States
Optimal Bi-Annual Tilt Angles and Optimal Tilt Transition Timing for Fixed Tilt Arrays in the United States
Abstract As global dependency on renewable energy grows, it is imperative to utilize every Photovoltaic (PV) panel in the most efficient way possible. An important c...
FLANGED INTRASCLERAL INTRAOCULAR LENS FIXATION USING 31G NEEDLES
FLANGED INTRASCLERAL INTRAOCULAR LENS FIXATION USING 31G NEEDLES
Purpose: To demonstrate the novel use of a 31-gauge needle for flanged intrascleral intraocular lens (IOL) fixation using the double-needle technique. ...
Comparison of Visual Outcomes of Extended Depth of Focus Lenses in Patients With and Without Previous Laser Refractive Surgery
Comparison of Visual Outcomes of Extended Depth of Focus Lenses in Patients With and Without Previous Laser Refractive Surgery
PURPOSE: To compare visual outcomes of eyes with and without previous laser refractive surgery that received an extended depth of focus intraocular lens during cataract...
Prevalence and associated factors of refractive error among adults in South Ethiopia, a community-based cross-sectional study
Prevalence and associated factors of refractive error among adults in South Ethiopia, a community-based cross-sectional study
IntroductionThe increasing prevalence of refractive error has become a serious health issue that needs serious attention. However, there are few studies regarding the prevalence an...
Comparison of Two Modified Sutureless Techniques of Scleral Fixation of Intraocular Lens
Comparison of Two Modified Sutureless Techniques of Scleral Fixation of Intraocular Lens
BACKGROUND AND OBJECTIVE: To compare the visual outcome and complications of two different sutureless scleral-fixated intraocular lens (IOL) implantation techniques, th...
Association of Different Type of Refractive Errors with Parental Cousin Marriages
Association of Different Type of Refractive Errors with Parental Cousin Marriages
Refractive errors are the major reason of visual impairment and its prevalence has increased over time. Refractive errors affect ocular structures as corneal shape, eye’s axial len...
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Background: Primarily ligamentous Lisfranc injuries occur in athletic populations. Unstable Lisfranc injuries are treated with internal fixation or arthrodesis. Interna...

Back to Top