Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of a Waterproof Device in the Noninvasive Ventilation Circuit on patient-machine Synchronization

View through CrossRef
Objective: Investigate the effect of connecting a waterproof device at the front end of the piezometric tube on pressure transmission and patient-machine synchronization during the noninvasive ventilation. Method: In test 1, the waterproof device was connected to the piezometric tube and put into a closed container, the pressure inside the container was varied to observe the corresponding pressure change in the piezometric tube. In test 2, a waterproof device was connected in front of the piezometric tube during noninvasive ventilation.12 subjects were received noninvasive ventilator so that dynamic changes of the pressure inside the mask (Pmask) and piezometric tube (Ptube) could be measured. Results: In test 1, when the pressure in the container was gradually increased to 50 cmH2O and then decreased to 0, the pressure inside the piezometric tube changed synchronously with the pressure inside the container, with no statistically significant difference between the pressures (0.009 ± 0.138) cmH2O. In test 2, there was no significant increase in triggering time, pressure, and power after connecting the waterproof device at the front end of the piezometric tube. There was no significant difference in the platform pressure and baseline pressure as measured by Pmask, before and after connecting the waterproof device. Finally, there was no significant difference in the platform pressure and baseline pressure between Pmask and Ptube after connecting the waterproof device.
Title: Effect of a Waterproof Device in the Noninvasive Ventilation Circuit on patient-machine Synchronization
Description:
Objective: Investigate the effect of connecting a waterproof device at the front end of the piezometric tube on pressure transmission and patient-machine synchronization during the noninvasive ventilation.
Method: In test 1, the waterproof device was connected to the piezometric tube and put into a closed container, the pressure inside the container was varied to observe the corresponding pressure change in the piezometric tube.
In test 2, a waterproof device was connected in front of the piezometric tube during noninvasive ventilation.
12 subjects were received noninvasive ventilator so that dynamic changes of the pressure inside the mask (Pmask) and piezometric tube (Ptube) could be measured.
Results: In test 1, when the pressure in the container was gradually increased to 50 cmH2O and then decreased to 0, the pressure inside the piezometric tube changed synchronously with the pressure inside the container, with no statistically significant difference between the pressures (0.
009 ± 0.
138) cmH2O.
In test 2, there was no significant increase in triggering time, pressure, and power after connecting the waterproof device at the front end of the piezometric tube.
There was no significant difference in the platform pressure and baseline pressure as measured by Pmask, before and after connecting the waterproof device.
Finally, there was no significant difference in the platform pressure and baseline pressure between Pmask and Ptube after connecting the waterproof device.

Related Results

Synchronization transition with coexistence of attractors in coupled discontinuous system
Synchronization transition with coexistence of attractors in coupled discontinuous system
The studies of extended dynamics systems are relevant to the understanding of spatiotemporal patterns observed in diverse fields. One of the well-established models for such comple...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash Abstract This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
TU‐H‐202‐02: Applications, Validation, Clinical Endpoints and Opportunities for CT Ventilation
TU‐H‐202‐02: Applications, Validation, Clinical Endpoints and Opportunities for CT Ventilation
CT ventilation imaging is an exciting functional imaging modality that combines four‐dimensional computed tomography (4DCT) and deformable image registration (DIR) to provide exqui...
Invasive Mechanical Ventilation Duration Prediction using Survival Analysis
Invasive Mechanical Ventilation Duration Prediction using Survival Analysis
Abstract Invasive mechanical ventilation is one of the leading life support machines in the intensive care unit (ICU). By identifying the predictors of ventilation ...
Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts
Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts
Nowadays, the electric connection circuits of power plants (based on fossil fuels as well as renewable sources) entail generator circuit-breakers (GCBs) at the generator terminals,...
Episodic ventilation lowers the efficiency of pulmonary CO2excretion
Episodic ventilation lowers the efficiency of pulmonary CO2excretion
The ventilation pattern of many ectothermic vertebrates, as well as hibernating and diving endotherms, is episodic where breaths are clustered in bouts interspersed among apneas of...
Passive Versus Active Circuit During Invasive Mechanical Ventilation in Subjects With Amyotrophic Lateral Sclerosis
Passive Versus Active Circuit During Invasive Mechanical Ventilation in Subjects With Amyotrophic Lateral Sclerosis
BACKGROUND: Until recently, it has been considered essential to maintain the use of a double-limb circuit in patients with amyotrophic lateral sclerosis (ALS) t...

Back to Top